Sign In         Specifying Software      
 
    Home        About Us        Contact Us        Help Buy Online or Call 1-800-476-5888  
 
 
TTV-M

INDUSTRIAL DIRECT FIRED VERTICAL 80/20 - SINGLE

 

List Parts

Call 800-476-5888 or Email for Pricing

 
  • Air Volume: 5,000 – 40,000 cfm
  • Maximum SP: 3" wg. @ standard air density
 

Print

 
 
 
   FEATURES & BENEFITS   
 
 
Casing
  • internal tubular frame
  • double wall doors
  • rear doors on Model22 & larger
  • G-90 galvanized steel
  • weatherproof construction
  • hinged service doors with flush-mount latches
  • six discharge options
Blower
  • FC-DWDI centrifugal blower assembly
  • v-belt drive
  • 100,000 hour greasable bearings (Model 18-236)
  • permanent lubricated bearings (Model 10-15)
  • solid steel shaft
  • split shafts with couplings on twin units
Burner
  • wide-range, high capacity line burner
  • up to 30:1 turndown ratio
  • electric-pilot spark ignition
Burner Economizer Thermostat
 
Burner-Observation Port
 
Manifold Controls Vestibule
  • weatherproof enclosure
  • easy-access to manifold and controls
  • manifold built to required codes
 
Electrical Controls Vestibule
  • weatherproof enclosure
  • easy-access to manifold and controls
  • exhaust-interlock terminals
  • terminal strip for quick service check
  • burner and blower service switches
Gas Connection
 
Motor
  • standard, high E, open-drip proof with adjustable motor mount
  • v-belt drive
  • adjustable drive up to and including 25 HP
  • starter with burner interlock
Lifting Eyes
  • standard heavy-duty lifting lugs
Controls
  • electronic flame safety controls
  • ignition transformer
  • airflow proving control
  • high-temperature safety controls
  • burner and blower service switches
Remote Control Panel
  • Summer-Off-Winter switch
  • "Blower on" light
  • "Burner on" light
  • Other lights available
Vertical Unit Diagram
Factory assembled, wired, and flame tested
  1. Casing
  2. Burner Profile
  3. Burner
  4. Blower
  5. Burner Observation Port
  6. Lifting Lugs
  7. Motor
  8. Gas Connection
  9. Main Fused Disconnect
  10. Manifold Controls Vestibule
  11. Electrical Controls Vestibule
 
 
 
   ACCESSORIES   
 
 
Discharge damper, two-position motor and interlock:
motor-operated parallel blade damper that prevents warm air from escaping the building through the unit. The motor-damper end switch energizes the starter circuit when the damper is in the full-open position, and returns to a closed position during shutdown.
 
Discharge louvers with air diffuser:
discharges air in four directions with vertical and horizontal blades, and is field-installed. The blades can be manually adjusted to set direction of airflow.
 
Filter section:
removable, hinged access door, with a 2-inch washable, aluminum-mesh filter, or a 2-inch pleated filter. Also available with 1-inch, 1.5 lb density insulation.
 
Inlet screen:
prevents material from entering unit. A 1-inch mesh screen fastens to unit's fresh-air intake.
 
Return-air filter, 80/20 units:
1-inch or 2-inch deep, aluminum mesh, or 2-inch deep, 30% efficient, pleated type; v-bank, filter section shipped loose for field mounting to the return-air connection.
 
 
 
 
   OPTIONS   
 
 
Adjustable drives:
fixed-pitched sheaves are standard on motors 30hp and larger. An adjustable-pitch motor sheave is provided in lieu of the standard fixed-pitch sheave.
 
Casing insulation:
adds 1", 1.5 lb density insulation, that is glued and pinned to inner surface of unit's walls and ceiling, casing liners are standard with this option.
 
Casing liners with insulation:
prevents insulation fibers from being drawn into air stream and discharged into conditioned space, and prevents physical abuse and moisture damage to insulation. Made of galvanized steel.
 
Extended grease lines:
lubrication lines from blower bearings to a common point on the unit's exterior. Units with permanently lubricated bearings to be changed to pillow block-type.
 
Painted casings:
one coat of beige air-dried enamel over a vinyl wash primer.
 
Pillow-block bearings, 100,000 hr:
standard on all units ordered with an industrial blower, and are rated at 100,000 to 200,000 hours; available on smaller units with standard, permanently lubricated ball bearings.
 
 
 
 
   CONTROLS AND CONTROL OPTIONS   
 
 
 
 
 
   DRAWINGS & SPECIFICATIONS   
 
 
 
 
 
   OPERATION & INSTALLATION MANUALS   
 
 
 
 
 
   ADDITIONAL INFORMATION   
 
 
 
 
 
   CERTIFICATIONS   
 
 

The TTV-M Model has been certified by ITS. This certification mark indicates that the product has been tested to and has met the minimum requirements of a widely recognized (consensus) U.S. products safety standard, that the manufacturing site has been audited, and that the applicant has agreed to a program of periodic factory follow-up inspections to verify continued performance.


Model TTV-M is ETL Listed under file number 3035352-002 and complies with ANSI Z83.18-2001 Standards.

 
 
 
 
 