INDUSTRIAL DIRECT FIRED HORIZONTAL - SINGLE

 

List Parts

Call 800-476-5888 or Email for Pricing

 
  • Air Volume: 5,000 – 46,000 cfm
  • Maximum SP: 5" wg. @ standard air density
 

Print

 
 
 
   FEATURES & BENEFITS   
 
 
Casing
  • G-90 galvanized steel
  • interlocked wall seam and roof panels
  • weatherproof construction
  • standing roof seams (Models 18 and larger)
  • single casing construction (Models 10-230)
  • hinged service doors with flush-mount latches
  • six discharge options
  • double wall doors
Burner Profile
  • adjustable profile plates
  • optional 80/20 arrangement
  • optional two-speed arrangement
  • optional VFD arrangement
Burner
  • wide-range, high capacity line burner
  • up to 30:1 turndown ratio
  • electric-pilot spark ignition
Burner Economizer Thermostat
 
Burner-Observation Port
 
Blower
  • FC-DWDI centrifugal blower assembly
  • v-belt drive
  • 100,000 hour greasable bearings (Models 18-230)
  • permanent lubricated bearings (Models 10-15)
  • solid steel shaft
  • split shafts with couplings on twin units
Gas Connection
 
 
Controls
  • electronic flame safety controls
  • ignition transformer
  • airflow proving control
  • high-temperature safety controls
  • burner and blower service switches
Base and Lifting Lugs
  • formed G-90 galvanized-steel base
  • direct floor or curb mount
  • standard heavy-duty lifting lugs
  • optional hanging-mount lifting lugs (Models 10-230)
Motor
  • standard, high E, open-drip proof with adjustable motor mount
  • v-belt drive
  • starter with burner interlock
  • adjustable drive up to and including 20 HP
Manifold Controls Vestibule
  • weatherproof enclosure
  • easy access to manifold and controls
  • manifold built to required codes (FM/IRI/FIA)
Electrical Controls Vestibule
  • weatherproof enclosure
  • easy access to manifold and controls
  • exhaust-interlock terminals
  • terminal strip for quick service check
  • Blower & burner service switches
Remote Control Panel
  • Summer-Off-Winter switch
  • "Blower on" light
  • "Burner on" light
  • Other lights available

Factory assembled, wired, and flame-tested
  1. Casing
  2. Burner Profile
  3. Burner
  4. Blower
  5. Burner Observation Port
  6. Base and Lifting Lugs
  7. Motor
  8. Gas Connection
  9. Main Fused Disconnect
  10. Manifold Control Vestibule
  11. Electrical Controls Vestibule
 
 
 
   ACCESSORIES   
 
 
Discharge damper, two-position motor and interlock:
motor-operated parallel blade damper that prevents warm air from escaping the building through the unit. The motor-damper end switch energizes the starter circuit when the damper is in the full-open position, and returns to a closed position during shutdown. Down discharge arrangement units available with our exclusive "Hassle Free Damper" internally mounted in unit.
 
Discharge louvers with air diffuser:
discharges air in four directions with vertical and horizontal blades, and is field-installed. The blades can be manually adjusted to set direction of airflow.
 
Filter section:
removable, hinged access door, with a 2-inch washable, aluminum-mesh filter, or a 2-inch pleated filter. Also available with 1-inch, 1.5 lb density insulation.
 
Fresh-air intake hood with birdscreen:
prevents rain or snow from entering the unit with a 1-inch mesh screen on hood face; sized to fit unit's fresh-air intake. Shipped loose to be field installed.
 
Full-downturn inlet hood:
prevents rain and snow from entering the unit by bringing air into the bottom of the hood with a 1-inch wire-mesh screen, and is field installed. Large hoods are shipped separately, and must be field assembled.
 
Inlet-hood filters, 2-inch:
cleanable, aluminum-mesh filters mounted on the inlet-hood face in lieu of a separate filter section. Not available on TTH-M 227 and larger models.
 
Inlet screen:
prevents material from entering unit. A 1-inch mesh screen fastens to unit's fresh-air intake.
 
Inlet damper, two-position motor and interlock:
motor-operated parallel blade damper that prevents outside air from entering the building through the unit. The motor damper end switch energizes the starter circuit when the damper is in the full-open position, and returns to a closed position during shutdown.
 
Return-air filter, 80/20 units:
2-inch deep, aluminum mesh, or 2-inch deep, 30% efficient, pleated type; v-bank, filter section shipped loose for field mounting to the return-air connection.
 
Standard curb:
24-inch roof curb formed of 12-gauge steel; 14-inch curb is also available. Shipped separately, and must be field assembled. Insulation, cant, and wood nailer by others
 
 
 
 
   OPTIONS   
 
 
Adjustable drives:
fixed-pitched sheaves are standard on motors 25 HP and larger. An adjustable-pitch motor sheave is provided in lieu of the standard fixed-pitch sheave.
 
Casing insulation:
adds 1", 1.5 lb density insulation to inner surface of unit's walls and ceiling, casing liners are standard with this option.
 
Casing liners with insulation:
prevents insulation fibers from being drawn into air stream and discharged into conditioned space, and prevents physical abuse and moisture damage to insulation. Made of galvanized steel.
 
Extended grease lines:
lubrication lines from blower bearings to a common point on the unit's exterior. Units with permanently lubricated bearings to be changed to pillow block-type.
 
Floor-mounted spring isolators:
box-type lifting points replace standard lifting eyes; 1-inch deflection spring mounts shipped loose for field installation.
 
Hanging spring isolators, 1-inch:
shipped loose for field installation.
 
Painted casings:
one coat of beige air-dried enamel over a vinyl wash primer.
 
Pillow-block bearings, 100,000 hr:
standard on all units ordered with an industrial blower, and are rated at 100,000 to 200,000 hours; available on smaller units with standard, permanently lubricated ball bearings.
 
Spring-isolated blower and motor:
mounted on a 1" deflection spring isolated base. A flexible duct connects the fan outlet to the unit's casing.
 
Two-speed damper package:
provides burner-profile dampers that automatically maintain the correct burner velocity. Also dual airflow switches and rate-limiting control are included to prevent over-firing on low speed.
 
 
 
 
   CONTROLS AND CONTROL OPTIONS   
 
 
 
 
 
   DRAWINGS & SPECIFICATIONS   
 
 
 
 
 
   OPERATION & INSTALLATION MANUALS   
 
 
 
 
 
   ADDITIONAL INFORMATION   
 
 
 
 
 
   CERTIFICATIONS   
 
 

The TTH Model has been certified by ITS. This certification mark indicates that the product has been tested to and has met the minimum requirements of a widely recognized (consensus) U.S. and Canadian products safety standard, that the manufacturing site has been audited, and that the applicant has agreed to a program of periodic factory follow-up inspections to verify continued performance.


Model TTH is ETL Listed under file number 3013648-002 and complies with ANSI Z83.4-Second Edition and CSA 3.7-2006 Standards.

 
 
 
 
 