Indirect Fired Bent Tube Module

 
Indirect Fired Bent Tube Module

List Parts

Call 800-476-5888 or Email for Pricing

Print

 
Indirect Fired Bent Tube Module

Providing clean and tempered makeup air to meet your application needs. The push-through design ensures that combustion fumes will not enter the fresh air stream.

The Modular Indirect Fired Bent Module is designed to deliver clean air into an indoor environment. The IBT heater module is approved in the United States and Canada. The unit is listed to the ANSI Z83.8-2006 and CSA 2.6-2006 standards. Each furnace has a 6:1 Turndown Ratio and a maximum Turndown of 28:1 for the entire unit, depending on total required BTU Capacity and number of furnaces in the unit.

Every unit is programmed to start in high fire mode to ensure consistent light-off and is equipped with an electronic, Vernier-type fully-modulating control system. The duct furnaces are all type-409 stainless steel, and certified by the American Gas Association and approved by the Canadian Gas Association. Each model utilizes a single modulating stage, and between zero and three additional ON/OFF stages depending on the required heat output. In addition, the speed of its power-vent blower on the single modulating furnace is varied as the gas flow changes, thereby maintaining a constant 80% combustion efficiency over the entire gas-firing range of the unit.

Efficiency Charts

Combination packages that include both exhaust and supply fans mounted on a single roof curb are also available; please contact your sales representative for more information.

 
 
 
   FEATURES & BENEFITS   
 
 
Bent Tube In-Shot Style Furnace with Type 409 Stainless Steel Heat Exchanger
80% Constant Efficiency over Entire Gas Firing Range
6:1 Turndown per Furnace, 28:1 Max
Full Electronic Vernier-type Modulation
Forced High Fire Start
Variable Speed Power-vent Motor
Discharge, Space or Building Automation System (BAS) Temperature Control
Isolated and Insulated Electrical Controls Vestibule
Natural Gas or Liquid Propane Applications
Inlet and Manifold Gas Pressure Indicating Gauges
Electronic Push Button adjustment for the Modulating Gas Valve
High Temperature Limit Switch
Flame Rollout Switch with Manual Reset
LED Indicators for Troubleshooting
Economizer Inlet Air Thermostat
 
 
 
   OPTIONS   
 
 
5:1 Turndown for Propane (LP) per Furnace. 23:1 Max
Up Discharge
Motorized Intake Damper
Remote Control Panel
High and Low Gas Pressure Switch
Mixing Box
Variable Air Volume (VAV) Controls
Double Wall Construction
Blower on Delay (Heat Exchanger Pre-heat)
Freeze-stat Option
Fire-stat Option
Convenience Outlet
Extended Drop
Single Point Electrical Connection
Control Cabinet Heater
Dirty Filter Airflow Switch
Auxiliary Starters
Roof Curbs
Indoor Hanging Cradle
 
 
 