TANK Fire Suppression

 
TANK Fire Suppression

List Parts

Call 800-476-5888 or Email for Pricing

Print

 

Electronic Detection: Wet Chemical Suppression

  • Faster and more accurate electrical detection
  • Monitored, supervised loops on all critical components
  • Low voltage interlock for multiple systems
  • Battery backup ensures safety even during power outage
  • Cloud-accessibility for monitoring functionality and activation
 
 
   FEATURES   
 
 
  • Firestat - An electronic, solid state firestat reliably detects fire in the system. If TANK detects a temperature above 360ºF or a rapid rise in temperature, the firestat contacts will close, energizing the fire system.
  • Electric System with Battery Backup - In the event of a power outage, TANK uses a battery backup to disrupt all appliances through electric gas valves and shunt trip breakers. TANK’s battery backup also powers fire monitoring, detection, and suppression.
  • Microprocessor Based Control - Instant notification of problems with the system
  • TANK Control Board - TANK’s control board provides all of the necessary monitoring, timing, and supervision functions required for reliable operation. If a fault is detected, an alarm will periodically sound and the "Fire System Activated" light will flash a fault code. The unit's display screen will show the specific fault detected.
  • Independent Supervised Loops - The supervised loops incorporate both redundancy and fault detection. The firestat and manual activation device are connected to the loops.
  • 24/7 Monitoring - System pressure is monitored at all times to ensure suppression tanks are full of agent and ready to discharge.
  • Overlapping Protection - Overlapping nozzles installed no greater than 36 inches apart and 35-50 inches above the cooking surface ensure an even and overlapping spray throughout the hazard zone.
  • Simplified Nozzle Design - The discharge nozzles have been tested to ensure overlapping spray for the hazard zone. Each nozzle must have a metal blow-off cap to keep the nozzle tip orifice free of grease build-up.
 
 
 
   ADDITIONAL INFORMATION   
 
 
 
 
 
   CERTIFICATIONS   
 
 

The TANK Fire Suppression System is a UL and ETL Listed system for wet chemical extinguishing system units. The TANK system is UL listed under file number EX27953 to meet requirements of UL 300; ULC Listed to meet requirements of ULC/ORD-C1254.6 and UL/ULC 1254; CE Marked; Meets requirements of NFPA 96 and NFPA 17A. The TANK Fire suppression system is ETL listed under Report Number 104560275SAT-003 to ANSI/CAN/UL/ULC 300.


The control package for TANK Fire Suppression is ETL listed under report number 101196419NYM-001 to the UL Standard 864 and CAN/ULC-S527-11; FDNY Certificate of Approval #5870

This product may be covered by one or more of the following patent number(s): (United States) 8378834, or other U.S. and foreign patents pending.

 
 
 
 
 
 
 