Sign In         Specifying Software      
 
    Home        About Us        Contact Us        Help Buy Online or Call 1-800-476-5888  
 
 
TTH 225 with 108" burner Parts
Motors, Pulleys, & Motor Specific Parts
Motor HP Phs Voltage FLA Shaft Frame Weight RPM Vendor
DTP0154 15.000 3 208-230/380/460 V 40.3-36.4/22.7/18.2 1.625" 254T 231 lbs 1755 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0204 20.000 3 208-230/460 V 53.7-48.6/24.3 1.625" 256T 269 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0254 25.000 3 208-230/460 V 65-58.8/29.4 1.875" 284T 339 lbs 1765 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0304 30.000 3 208-230/460 V 76.7-69.4/34.7 1.875" 286T 283 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DHP0404 40.000 3 208-230/460 V 102.4-92.6/46.3 2.125" 324T 338 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DHP0504 50.000 3 208-230/460 V 128.9-117/58.3 2.125" 326T 440 lbs 1775 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0154 15.000 3 190/208-230/380/460 V 41.8/38.2-34.5/20.9/17.3 1.625" 254T 250 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0204 20.000 3 190/208-230/380/460 V 55.7/50.8-46/27.8/23 1.625" 256T 287 lbs 1760 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
02018ET3H256T-W22 20.000 3 575 V 19.3 1.625" 256T 396 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
02518ET3H284T-W22 25.000 3 575 V 23.6 1.875" 284T 412 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0254 25.000 3 208-230/460 V 64.3-58.2/29.1 1.875" 284T 358 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0304 30.000 3 208-230/460 V 75.8-68.6/34.3 1.875" 286T 436 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
03018ET3H286T-W22 30.000 3 575 V 28.1 1.875" 286T 450 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
04018ET3H324T-W22 40.000 3 575 V 37.7 2.125" 324T 574 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0404 40.000 3 208-230/460 V 102.3-92.6/46.3 2.125" 324T 661 lbs 1770 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
05018ET3H326T-W22 50.000 3 575 V 47.4 2.125" 326T 595 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0504 50.000 3 208-230/460 V 125-113.8/56.9 2.125" 326T 686 lbs 1770 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts

The manufacturer reserves the right to use alternate motors from alternate vendors that meet the operating requirements of the fan but may have slightly different specifications.
Intakes & Intake Parts
Part
IH7-O-FDH Full downturn intake hood.
IH7-O-IHNF Intake Hood - 140.25" Width X 69.50" Length X 46.75"
IH7-O-IH2"EZ Intake Hood Outdoor - 140.25" Width X 69.50" Length X 46.75" Height With 2" EZ Filter Max CFM = 45281
Show parts
IH7-O-VB2"TA-FDH V-BANK - 140.25" Width X 80" Length X 46.75" Height, Standard 2" TA Filter With Full Downturn Hood MERV 8 Filters
Show parts
IH7-O-VB2"EZ-IH2"EZ V-BANK - 140.25" Width X 97.5" Length X 46.75" Height, Standard 2" EZ Filter With Intake Hood
Show parts
IH7-I-VB2"TA V-BANK - 140.25" Width X 28" Length X 46.75" Height for Horizontal Industrial With Standard 2" Pleated Filter MERV 8 Filters
Show parts
IH7-I-VB2"TA13 V-BANK - 140.25" Width X 28" Length X 46.75" Height for Horizontal Industrial With Standard 2" Pleated Filter MERV 13 Filters
Show parts
IH7-I-VB2"EZ V-BANK - 140.25" Width X 28" Length X 46.75" Height for Industrial Horizontal With Standard 2" EZ Filter
Show parts
IH7-O-VB2"TA13-VB2"TA-IHNF V-BANK - 140.25" Width X 80" Length X 46.75" Height, Standard 2" TA Filter With Full Downturn Hood MERV 13 Filters
Show parts
IH7-O-VB2"EZ-IHNF V-BANK - 140.25" Width X 95.50" Length X 46.75" Height With Standard 2" EZ Filter And Intake Hood w/ No Filters
Show parts
IH7-O-VB2"TA13-IHNF V-BANK - 140.25" Width X 95.50" Length X 46.75" Height With Standard 2" Pleated Filter w/Intake Hood w/No Filters MERV 13 Filters
Show parts
IH7-O-VB2"TA-IHNF V-BANK - 140.25" Width X 95.50" Length X 46.75" Height With Standard 2" Pleated Filter w/Intake Hood w/No Filters MERV 8 Filters
Show parts
Temperature Controls

No Temperature Controls Found.

Gas Manifold Parts

No Gas Manifold Parts Found.

Blower
Part
A225-25H Two 25" Blowers - Enamel finish, pillow block bearing, 30000-56000, 50 HP, 2 3/16 Shaft, 900 MAX RPM, used in heated and non-heated supply fans
Burner
Part
R7-9-108 Direct-fired burner assembly. 4,950,000 BTU/HR Maximum, 165,000 minimum. 108" long. Used in sizes 7-9 industrial vertical and horizontal direct-fired heaters. Used for both Natural and Propane Gas. Pilot/Flame Rod/Spark Assembly included.
 
1190850
[1 used]
BURNER PART - "BRUTE" PILOT ASSEMBLY W/ SPARK & FLAME ROD. Pilot hole size is drill #50 (.070 diameter) (342B) (A0003270) Includes pack of boots and hardware. REPLACES 1190870
 
1060810
[2 used]
BURNER PART - 12" STRAIGHT BACK INLET SECTION - HMA-2A (Aluminum)
 
1010810
[7 used]
BURNER PART - 12" STRAIGHT SECTION - HMA-2A (Aluminum)
 
1372-52
[2 used]
BURNER PART - BLANK END FLANGE - ALUMINUM
 
1354-50
[1 used]
BURNER PART - SS End Plate
 
1354-60
[1 used]
BURNER PART - SS End Plate W/ PILOT MOUNT
Replacement Parts
Part
PN10-10RX-L
[1 used]
Yellow Ring Expanded Entry for GTO Cable - Panduit Used on ignition transformers
HMI_Bracket
[1 used]
20 GA. Galvanized. Used on IBT controls
Controller&HMI
HMI_01_MUA_POPULATED
[1 used]
HMI assembly. Preprogrammed for use with MUA Board. Includes CASHMI PCB, 4 mounting screws, 16 ga. SS backing plate, membrane switches & gasket. HMI should have populated RH sensor.
Coupler
2 3/16" BUSHING SF
[2 used]
2 3/16" BUSHING SF will take 2 to make up coupler
11B FLANGE
[2 used]
Flange 11B will take two to make up coupler, match with 11E sleeve and SF bushing.
11E SLEEVE
[1 used]
SLEEVE 11E will take one to make up coupler. Match with two 11B flanges.
Direct Fired Air Movement Control Components
17045A
[4 used]
Airflow Switch Components Cleveland Controls Airflow Probe 4".
Direct Fired Components
85000.002
[4 used]
Standard Lifiting Eye for Industrial Horizontal Heaters Size 2-8, 3/8" plate.
Direct Fired Flame Control Components
M4RT1
[1 used]
Fireye Flame Safety Control. Direct replacement for M series 2. Pre-purge preset 5 Sec. PTFI preset 10 Sec. Recycles once only after flame signal loss. Wiring connections are identical to M series 2.
Miscellaneous Electrical Parts
CAT5_3FT
[1 used]
3 Foot Long CAT5 Cable
MUA Board
[1 used]
Printed Circuit board for use in heaters. Used in conjunction with CAS HMI.
Miscellaneous Heater Components
62-99-805-20
[2 used]
Door latch used on industrial units, can be locked unlocked with tool
62-99-804-20 (P90-9910)
[2 used]
Door latch used on make up air units and pollution control units, no tool needed for access. Includes gasket. A0006143
206525
[1 used]
Yellow Label Sheet Package for Industrial MAUs.
Product Manuals
MANUAL INDUST
[1 used]
Manual for Industrial Direct Fired Heaters.
Thermostats/Sensors
A/CP-DO-240-QC
[2 used]
10K, Type II thermistor with 6" probe. 20' wire leads. (Replaces part# A/CP-DO-120-QC)
Transformers
1092TYPEF
[1 used]
Ignition Transformer 120V, 180VA, Output 6000 Volts Used with direct fired heaters
BE161640GEK0018
[1 used]
TRANSFORMER - Low 40VA Voltage Transformer Used for 120v Primary and 24v Secondary.
Options
Part
AALARM Audible Alarm, 120v,(Alarm sounds on flame failure).
Show parts
6631T18 Combustible Gas and Carbon Monoxide Detector 120VAC input. On-Board 10A, 250V Relay and 85db Audible Alarm. 150ppm CO, 17ppm H2, 5000 ppm Methane, 35ppm Propane. (HIC-822). 10,000 cubic feet recommended coverage per detector.
CODTIL Detector/Alarm Interlock (By Others)
D4120-DST-1.5 Duct Mounted Smoke Detector For Direct Fired Heater. Complete with detector (D4120) and sampling tube (DST-1.5). Ships Loose.
Show parts
SMDTIL Smoke Detector Interlock (By Others)
XBINDTWIN Extra Set of V-Belts For Twin Industrial Units. Only to be ordered as fan option at time fan is ordered.
EGL-7 Size 7 Industrial Heater Extended Grease Lines
Show parts
CABHTR100WNC Control panel enclosure heater, includes 100w, 120v heater. Recommended for winter design temperature less than 0°F. Operates on PCB controls in IBT Single Modules or RTU
Show parts
CABHTR200W Control panel enclosure heater, includes 200w, 120v heater and thermostat (10 degree setting). Requires convenience outlet option (power by others). Recommended for winter design temperature less than 0°F. - Old Controls
Show parts
BHE Box Hanging Eyes (set of 4) for Industrial Direct Fired Heaters (Sizes 2-8)
Show parts
NON SILICONE Fan housing assembled without the use of silicone caulk. Primarily used for paint booth applications. Use Acrylic Latex Caulk , P/N A0011848.
POC Proof of closure option for industrial direct fired heaters. One motorized valve must be included in gas manifold.
CINSUL-7 Size 7 Industrial Heater Casing Insulation with Steel Liner
FLINSUL-7 Size 7 Industrial Heater Floor Insulation with Steel Liner
Cooling Interlock Cooling Interlock Between Remote Panel and Heater
CIR-IN Cooling Interlock Relay Mounted in Unit - After Air Proving and Intake Air Stat.
Show parts
A225SDAD-R 180° Side Discharge Air Diffuser A225
A225DDAD3W 3-Way Down Discharge Air Diffuser A225
Show parts
A225DDAD4W 4-Way Down Discharge Air Diffuser A225
Show parts
DSD-225V Straight Run Diffuser Ductwork for A225 Diffuser. 3 Feet Long, 18ga.
NON_FUSED_DISC_IND_SEP120 Non-Fused Disconnect Switch for Industrial Make Up Air Units, Sep 120v Connection.
NON_FUSED_DISC_IND_SP Non-Fused Disconnect Switch for Industrial Make Up Air Units, Single Point Connection.
PRESSGA15 Gas Pressure Gauge, 0-15PSI, 2.5" Diameter, 1/4" Thread Size
PRESSGA35 Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size
PRESSGA5 Gas Pressure Gauge, 0-5#, 2.5" Diameter, 1/4" Thread Size
PRESSGA-5-0+15 Gas Pressure Gauge, -5 to +15 Inches Wc., 2.5" Diameter, 1/4" Thread Size
PRESSGA35 Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size
PRESSGA15 Gas Pressure Gauge, 0-15PSI, 2.5" Diameter, 1/4" Thread Size
GMH-A4-4-4 High Gas Pressure Switch (1" - 20" WC) Factory set at 8" w.c. Replaces part HGP-A.
LGPSO Low Pressure Gas Switch (1" - 6" WC) Factory set at 2" w.c.
Show parts
Gas Strainer 1 1/2" Ship Loose Gas Strainer. To be installed upstream of unit connection. 1 1/2" Connection
Show parts
Gas Strainer 1 1/4" Ship Loose Gas Strainer. To be installed upstream of unit connection. 1 1/4" Connection
Show parts
Gas Strainer 1" Ship Loose Gas Strainer. To be installed upstream of unit connection. 1" Connection
Show parts
Gas Strainer 2 1/2" Ship Loose Gas Strainer. To be installed upstream of unit connection. 2 1/2" Connection
Show parts
Gas Strainer 2" Ship Loose Gas Strainer. To be installed upstream of unit connection. 2" Connection
Show parts
Gas Strainer 3/4" Ship Loose Gas Strainer. To be installed upstream of unit connection. 3/4" Connection
Show parts
CLCOMM_REV04 CASLink building monitoring system communications module. Requires internet & field wired ethernet connection or 3G cellular service. Includes Rev 3 Comm Module, RJ45 to modbus converter, 3 FT cat5 cable, and 1 FT of shielded twisted pair.
Show parts
DDC-IP BACnet Monitoring Remote IP BACnet monitoring for supply fans.
Show parts
DDC-MSTP BACnet Monitoring Remote MSTP BACnet monitoring
Show parts
Dry Mode Dry Mode
Show parts
FECONTAAFS Field Wired Exhaust Contactor After Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP 230v, 15HP max. 460V, 15HP max. 575V or (4) Dry Interlocks. Overload not Included
Show parts
FECONTBAFS Field Wired Exhaust Contactor Before Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP max 230v, 15HP max. 460V. Overload not Included
Show parts
FECONTBAFS Field Wired Exhaust Contactor Before Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP max 230v, 15HP max. 460V. Overload not Included
Show parts
Exhaust on Fire Exhaust on Fire
FEInterBAFS Relay for Field wired Exhaust Interlock. Located before airflow switch.
Show parts
LFS Low Fire Start. Allows the burner circuit to energize when the modulation control is in a low fire position.
MAN RES FSC Manual reset of flame safety controller. Used to meet Canada requirement. Flame safety will not reset on cycle of power. Dips 1,2,3,5 closed, 4, 6 open standard settings.
OCCUPIED SCHEDULING Occupied Scheduling Defaulted for IBT/RTU.
OPPSIDE-TWINIH-CTRLS Mount motor and controls on opposite side of heaters with double blowers
INSUEXPV Supply and exhaust (exhaust by others) proving for industrial make up air units. Includes timed relay, requires field supplied exhaust interlock.
Show parts
Supply Fan Preset Speed Supply Fan Preset Speed Input to PCB. Field Wired.
CLOGFILTHMI Clogged Filter Switch with Notification on HMI
Show parts
CLOGFILT Clogged Filter Switch with Light on Remote Panel
Show parts
PBCLOGFILT Clogged Filter Switch with Light on Paint Booth Control Panel
Show parts
Control Vestibule LED Lights Control Vestibule LED Lights Used on Industrial Units.
Show parts
CVOUTLET GFCI 15 amp Convenience Outlet For Heater Enclosure. Power supply by others - Includes receptacle and J box.
INDPCVOUTLET GFCI 15 amp Powered Convenience Outlet For Industrial units with 208/230/460 power. Includes receptacle, jbox, cover and transformer. Not available with ship loose vfd.
Show parts
N.O. Contacts Extra set of N.O. contacts on supply starter.
Purge mode Purge option selected. Allows the user to purge the space by manually activtating on the HMI.
Show parts
Shaft Grounding Ring Option Shaft Grounding Ring Option
A225DDD-R INS External Down Discharge Insulated Damper for size 7 horizontal industrial units with (2)25" blowers. Includes actuator. Insulated blades and frame. Thermally broken blades. Non-stock option, lead time 6 weeks.
Show parts
A225DDS-R INS External Side Discharge Insulated Damper for size 7 Horizontal industrial units with (2)25" blowers. Includes actuator. Insulated blades and frame. Thermally broken blades. Non-stock option, lead time 6 weeks.
Show parts
R7 ID INS Size 7 Horizontal Industrial Heater Insulated Intake Damper. Includes Actuator. Non-stock option, lead time 6 weeks.
Show parts
A225DD-DM External Discharge CD60 Damper for size 7 industrial units with (2)25" blowers. Includes actuator.
Show parts
A225DDD-R External Down Discharge CD60 Damper for size 7 horizontal industrial units with (2)25" blowers. Includes actuator.
Show parts
FIELDDMP(S) Field Supplied Damper(s) Indicated By Others
A225DDI Internal Down Discharge Damper for size 7 industrial horizontal units with (2) 25" inch blowers. Includes actuators.
Show parts
A225DDS-R External Side Discharge CD60 Damper for size 7 Horizontal industrial units with (2)25" blowers. Includes actuator.
Show parts
R7 ID-SL Size 7 Horizontal Industrial Heater Intake Damper. Includes Actuator. SHIPS LOOSE For Mounting at Building Wall.
Show parts
PB-VFD-BSPC-AB Auto Balance Exhaust VFD Static Pressure Control (preset to: -0.01 and 0.02)
Show parts
PB-BSPC-AB Auto Balance Exhaust Static Pressure Controls, vfd not included (preset to: -0.01 and 0.02)
Show parts
PB-VFD-RMP-MB Manual Balance Exhaust VFD Control
PB-LC Paint Booth Lighting Circuit Switch Only.
PB-LC-AO Paint Booth Lighting Circuit Switch and Auto Off in Cure Mode.
PB-PURGE Paint Booth Purge Cycle with Light
CONSERVETMR Spray mode energy conservation timer, reduces cfm's if spray not active. Factory set for 5 minutes. Requires mau vfd.
Show parts
ENAM-7 Tan Enamel Coating (exterior walls/roof) For Heaters with 222"-225" blower wheels, includes casing and intakes. Consult factory for other colors. Sherwin Williams p/n F75KXN5809-4347, (AX = A0006229)
NOSTOVVFD-TWIN No starter/overloads installed in unit, no vav profile package, includes VFD for soft start operation (ship loose is default).
Show parts
NOSTOV-TWIN No starter/overloads installed in unit, non-fused disconnect switch, vfd for soft start by others, no vav profile package provided.
Show parts
VAV-PWP7-DCV Size 7 VAV Profile and Wiring Package, For Use With DCV.
Show parts
VAV-PWP7-ND Size 7 VAV Profile and Wiring Package. No VFD included
Show parts
VAV-PWP7-ND-NP Size 7 VAV Profile and Wiring Package. No VFD included
Show parts
VAV-PWPH7-BSPC Size 7 Horizontal Heater VAV Profile and Wiring Package w/ Building Static Pressure Control
Show parts
VAV-PWPH7-BSPC-PCBMUA Size 7 Horizontal Heater VAV Profile and Wiring Package w/ Building Static Pressure Control used with MUA Board
Show parts
VAV-PWPH7-403G Size 7 Horizontal Heater VAV Profile and Wiring Package w/ CO Detector (by others) Speed Control
Show parts
VAV-PWPH7-CSAI-PCB Size 7 Horizontal Heater VAV Profile and Wiring Package w/ Constant Speed Control or Analog Input Control PCB
Show parts
VAV-PWPH7-CSAI Size 7 Horizontal Heater VAV Profile and Wiring Package w/ Constant Speed Control or Analog Input Control
Show parts
VAV-PWPH7-M Size 7 Horizontal Heater VAV Profile and Wiring Package w/ Manual Adjustment
Show parts
VAV-PWPH7-MAN-PCB Size 7 Horizontal Heater VAV Profile and Wiring Package w/ Manual Control PCB
Show parts
VAV-PWPV7-CSAI Size 7 Vertical Heater VAV Profile and Wiring Package w/ Constant Speed Control or Analog Input Control
Show parts
FIRESTAT-DISCHARGE Discharge Firestat for Heaters Set to 240°F - Old Controls
Show parts
FREEZESTAT- Freezestat factory set at 35°F and 10 minutes.
FRSTAT-20 Freezestat With 20' Sensor. Factory set at 35°F and 10 minutes.
Show parts
FRSTAT-20-LTL Freezestat With 20' Sensor and Low Temp Light on Remote Panel. Factory set at 35°F and 10 minutes.
Show parts
FRSTAT-20-LTL Freezestat With 20' Sensor and Low Temp Light on Remote Panel. Factory set at 35°F and 10 minutes.
Show parts
FIRESTAT-INTAKE Intake Firestat for Heaters Set to 135°F - Old Controls
Show parts
IBT/DF/RTU Nema 4x remote Space Sensor Nema 4x Remote Room Sensor Option. Wall Mountable 10k Room Sensor Included.
Show parts
A/CP-D-12"-GD 10k Type 2 Thermistor with 12 Inch Probe
IBT/RTU remote Space Sensor Remote Room Sensor Option. Wall Mountable 10k Room Sensor Included.
Show parts
PRE-PT Pre purge (set at 30 seconds) allowing the blower to purge the inside of the heater.
R7VBI Size 7 Horizontal Industrial Vbank Insulation Upgrade
LOADREACTORININD Mount Load Reactor in Industrial Mau (Does not include reactor cost, just mounting).
SPVCM Unit Mount Static Pressure VFD Control (preset to: -0.01 and 0.02)
FMSVI-7 Floor Mounted Spring Vibration Isolators for Industrial Size 7 Heaters and Supply Fans. Cannot be used in conjunction with curb.
Show parts
HSVI-7 Hanging Spring Vibration Isolators for Size 7 Industrial Heaters and Supply Fans. Cannot be used in conjunction with curb.
 
 
 

Security Policy     Privacy Policy     Legal Notice     Warranty     Return Policy