Sign In         Specifying Software      
 
    Home        About Us        Contact Us        Help Buy Online or Call 1-800-476-5888  
 
 
T1-IBT-200-16Z Parts
Motors, Pulleys, & Motor Specific Parts
Motor HP Phs Voltage FLA Shaft Frame Weight RPM Vendor
186725/A01–ECM-50-277-16 1.750 1 208-220-230-240-277 V 6.2-5.8-5.6-5.3-4.6 0.000" 49 lbs 2390 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
186725/A01–ECM-60-277-16 1.750 1 208-220-230-240-277 V 6.2-5.8-5.6-5.3-4.6 0.000" 49 lbs 2390 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
186728/A01–ECM-50-240-16 2.500 3 200-208-220-230-240 V 5.9-5.7-5.4-5.1-4.9 0.000" 55 lbs 2770 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
186728/A01–ECM-60-240-16 2.500 3 200-208-220-230-240 V 5.9-5.7-5.4-5.1-4.9 0.000" 55 lbs 2770 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
186727/A01-ECM-50-480-16 3.400 3 380/400/415/440/460/480 V 4/3.8/3.7/3.4/3.3/3.2 0.000" 49 lbs 3000 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
186727/A01-ECM-60-480-16 3.400 3 380/400/415/440/460/480 V 4/3.8/3.7/3.4/3.3/3.2 0.000" 49 lbs 3000 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts

The manufacturer reserves the right to use alternate motors from alternate vendors that meet the operating requirements of the fan but may have slightly different specifications.
Intakes & Intake Parts
Part
CD-VB-I-01MIF-TA Celdek and V-Bank for Size # 1 Modular Indirect-Fired Heater with TA filters. For indoor installation. MERV 8 V-Bank Filters.
Show parts
CD-VB-I-01MIF-TA-13 Celdek and V-Bank for Size # 1 Modular Indirect-Fired Heater with TA filters. For indoor installation. MERV 13 V-Bank Filters.
Show parts
CD-VB-I-01MIF Celdek and V-Bank for Size # 1 Modular Indirect-Fired Heater. For indoor installation.
Show parts
CD-VB-O-01M-HE Celdek and V-Bank for Size # 1 Modular Supply unit with HE filters. For outdoor installation. MERV 15 V-Bank Filters. Includes Screened Intake
Show parts
CD-VB-O-01M-HE-IL Celdek and V-Bank for Size # 1 Modular Supply unit with HE filters. For outdoor installation. MERV 15 V-Bank Filters. Includes Intake Louver.
Show parts
CD-VB-I-01M-HE Celdek and V-Bank for Size # 1 Modular Supply unit with HE filters. For indoor installation. MERV 15 V-Bank Filters.
Show parts
CD-VB-O-01M-HEPA Celdek and V-Bank for Size # 1 Modular Supply unit with HEPA filters. For outdoor installation. Includes Screened Intake
Show parts
CD-VB-O-01M-HEPA-IL Celdek and V-Bank for Size # 1 Modular Supply unit with HEPA filters. For outdoor installation. Includes Intake Louver.
Show parts
CD-VB-I-01M-HEPA Celdek and V-Bank for Size # 1 Modular Supply unit with HEPA filters. For indoor installation.
Show parts
CD-VB-O-01M-TA Celdek and V-Bank for Size # 1 Modular Supply unit with TA filters. For outdoor installation. MERV 8 V-Bank Filters. Includes Screened Intake
Show parts
CD-VB-O-01M-TA-13-IL Celdek and V-Bank for Size # 1 Modular Supply unit with TA filters. For outdoor installation. MERV 13 V-Bank Filters. Includes Intake Louver.
Show parts
CD-VB-O-01M-TA-IL Celdek and V-Bank for Size # 1 Modular Supply unit with TA filters. For outdoor installation. MERV 8 V-Bank Filters. Includes Intake Louver.
Show parts
CD-VB-O-01M-TA-13 Celdek and V-Bank for Size # 1 Modular Supply unit with TA filters. For outdoor installation. MERV 13 V-Bank Filters. Includes Screened Intake
Show parts
CD-VB-O-01M Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
CD-VB-O-01M-IL Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
CD-O A1IF Celdek Evaporative Cooler for Size # 1 Modular Indirect-Fired Heater. 26.75" Wide X 54.5" Long X 36.688" High. Includes screened intake. For outdoor installation. Use with water softener recommended.
Show parts
CD-I A1IF Celdek Evaporative Cooler for Size # 1 Modular Indirect-Fired Heater. 26.75" Wide X 32.125" Long X 29.688" High. For indoor installation. Min. water pressure for optimal performance is 30 PSI. Max. water pressure should not exceed 50 PSI. Use with water softener recommended.
Show parts
CD-O A1IF-IH Celdek Evaporative Cooler for Size # 1 Modular Indirect-Fired Heater. 26.75" Wide X 76.438" Long X 29.688" High. Includes intake hood with filters. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A1IF-NF Celdek Evaporative Cooler for Size # 1 Modular Indirect-Fired Heater. 26.75" Wide X 76.438" Long X 29.688" High. Includes intake hood without filters. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A1-IL Celdek Evaporative Cooler for Size # 1 Modular Un-tempered Supply Air Unit. 26.75" Wide X 54.5" Long X 36.688" High. Includes intake louver. For outdoor installation.
Show parts
SI-1 Screen Intake for Size 1 Commercial Fans.
Show parts
CD-O A2IF-1 Size # 2 Celdek Evaporative Cooler for Size # 1 Modular Indirect-Fired Heater. 36.75" Wide X 62.438" Long X 36.688" High. Includes screened intake. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A2IF-IH-1 Size # 2 Celdek Evaporative Cooler for Size # 1 Modular Indirect-Fired Heater. 36.75" Wide X 85.812" Long X 36.688" High Includes intake hood with filters. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A2IF-NF-1 Size # 2 Celdek Evaporative Cooler for Size # 1 Modular Indirect-Fired Heater. 36.75" Wide X 85.812" Long X 36.688" High Includes intake hood without filters. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A2-1-IL Size # 2 Celdek Evaporative Cooler for Size # 1 Modular Un-tempered Supply Air Unit. ~36.75" Wide X 62.438" Long X 36.688" High. Includes intake louver. For outdoor installation. Use with water softener recommended.
Show parts
CD-I A2IF-1 Size 2 Celdek Evaporative Cooler for Size # 1 Modular Indirect-Fired Heater. 36.75" Wide X 32.125" Long X 36.688" High For indoor installation. Min. water pressure for optimal performance is 30 PSI. Max. water pressure should not exceed 50 PSI. Use with water softener recommeded.
Show parts
CD-LPD-VB-I-02-1M-TA-13 Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For indoor installation.
Show parts
CD-LPD-VB-I-02-1M-TA Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For indoor installation.
Show parts
CD-LPD-VB-I-02-1M Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For indoor installation.
Show parts
CD-LPD-VB-I-02-1M-HE Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For indoor installation.
Show parts
CD-LPD-VB-I-02-1M-HEPA Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For indoor installation.
Show parts
CD-LPD-VB-O-02-1M-HEPA Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
CD-LPD-VB-O-02-1M-HE Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
CD-LPD-VB-O-02-1M Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
CD-LPD-VB-O-02-1M-TA Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
CD-LPD-VB-O-02-1M-TA-13 Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
CD-LPD-VB-O-02-1M-IL Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
CD-LPD-VB-O-02-1M-HE-IL Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
CD-LPD-VB-O-02-1M-HEPA-IL Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
CD-LPD-VB-O-02-1M-TA-IL Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
CD-LPD-VB-O-02-1M-TA-13-IL Size 2 LPD Celdek and V-Bank for Size # 1 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
SFIH-01MID Sloped Filtered Intake for Size #1 Modular Indirect-Fired Heater. 21.813" Wide x 44.375" Long x 23.375" High. Includes 2" MV EZ Kleen Metal Mesh Filters.
Show parts
SFIH-01S Sloped Filtered Intake for Size #1 Standard Untempered Supply Unit. 22" Wide x 25.875" Long x 23.375" High. Includes 2" MV EZ Kleen Metal Mesh Filters.
Show parts
TL-01S TRUNKLINE - Extended Intake for size 1, standard untempered MUA unit, 19.75" Width, 114" Length, 21.32" Height Includes intake hood with 2" EZ Kleen metal mesh filters, and 87.75" long extension.
Show parts
VB-I-01MIF-TA V-Bank for Size # 1 Modular Indirect-Fired Heater with TA filters. For indoor installation. MERV 8 V-Bank Filters.
Show parts
VB-I-01MIF-TA-13 V-Bank for Size # 1 Modular Indirect-Fired Heater with TA filters. For indoor installation. MERV 13 V-Bank Filters.
Show parts
VB-I-01MIF V-Bank for Size # 1 Modular Indirect-Fired Heater. EZ Metal Mesh Filters. For indoor installation.
Show parts
VB-O-01M-HE-IL V-Bank for Size # 1 Modular Make-Up Air unit with HE Filters. Includes intake louver. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
VB-O-01M-HEPA-IL V-Bank for Size # 1 Modular Make-Up Air unit with HEPA filters. Includes intake louver. For outdoor installation.
Show parts
VB-O-01M-TA-13-IL V-Bank for Size # 1 Modular Make-Up Air unit with TA Filters. Includes intake louver. For outdoor installation. MERV 13 V-Bank Filters
Show parts
VB-O-01M-TA-IL V-Bank for Size # 1 Modular Make-Up Air unit with TA Filters. Includes intake louver. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
VB-O-01M-IL V-Bank for Size # 1 Modular Make-Up Air unit. EZ Metal Mesh Filters. Includes intake louver. For outdoor installation.
Show parts
VB-I-01M-HE V-Bank for Size # 1 Modular Supply unit with HE filters. For indoor installation. MERV 15 V-Bank Filters.
Show parts
VB-I-01M-HEPA V-Bank for Size # 1 Modular Supply unit with HEPA filters. For indoor installation.
Show parts
VB-O-01M-TA-13-IH-EZ V-Bank for Size #1 Modular Indirect-Fired Heater with TA Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
VB-O-01MIF-TA V-Bank for Size #1 Modular Indirect-Fired Heater with TA Filters. Includes screened intake. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
VB-O-01MIF-TA-13 V-Bank for Size #1 Modular Indirect-Fired Heater with TA Filters. Includes screened intake. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
VB-O-01MIF V-Bank for Size #1 Modular Indirect-Fired Heater. EZ Metal Mesh Filters. Includes screened intake. For outdoor installation.
Show parts
VB-O-01M-HE-IH-EZ V-Bank for Size #1 Modular Make-Up Air unit with HE Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
VB-O-01M-HEPA-IH-EZ V-Bank for Size #1 Modular Make-Up Air unit with HEPA filters. Includes intake hood with EZ filters. For outdoor installation.
Show parts
VB-O-01M-TA-IH-EZ V-Bank for Size #1 Modular Make-Up Air unit with TA Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
Temperature Controls

No Temperature Controls Found.

Gas Manifold Parts

No Gas Manifold Parts Found.

Blower
Part
16Z-1-MOD 16 Inch Plenum Fan for size 1 MOD. Motor integral to Wheel. Max RPM = 3000
Burner
Part
IBT200 Bent Tube Furnace - 200,000 BTU/HR maximum input, 160,000 BTU/HR maximum output, 26,667 BTU/HR minimum output for NG, 32,000 BTU/HR minimum output for LP. Includes (1) 200 MBH Input Furnace. Stainless Steel Burner, Heat Exchanger, and Power Vent. No contols or sheet metal housing. Used in size 1 and 2 IBT.
 
CP708IBT
[1 used]
FURNACE - 200,000 BTU/HR Indirect Fired Bent Tube Furnace with Stainless Steel Heat Exchanger, Burner, and Power Vent. No contols or sheet metal housing. Indoor use only. Used in IBT.
Replacement Parts
Part
33008
[24 used]
A0003208 - 3/8" WASHERS
8003
[3 used]
CONDUIT CONNECTOR - 90deg; 1/2" Bridgeport, 1/2" long thread
5RS
[1 used]
5" MV Storm Collar
5BVVTH
[1 used]
5'' DuraVent Type B High-Wind Cap. High Wind B Vent cap meets the UL standard for "high Wind" which is a 45 MPH test. Direct replacement for part number 5RHW and 5GVVTH.
5RP12
[2 used]
B-Vent, 5 inch diameter, 12 inches long. Used in IBT.
5RP18
[1 used]
B-Vent, 5 inch diameter, 18 inches long. Used in IBT.
90416
[1 used]
High Temp Silicone Rubber Tubing for IBT power vent. Durometer=50, .25" OD, .125" ID, 450°F Max continuous temperature. Sold Per foot.
P5BT235
[1 used]
Square to Round Adapter Used on IBT Heaters. Adapts Power Vent to 5" Round B-Vent. Small Adapter.
Common Heater Components
HMI_Bracket
[1 used]
20 GA. Galvanized. Used on IBT controls
Common Heater Electrical Components
SU201M-K10
[1 used]
CIRCUIT BREAKER - 10 AMP Circuit Breaker Used for Indirect Heaters. Trip Curve D. UL489. Old P/N S201U-K10
Controller&HMI
HMI_01_IBT
[1 used]
HMI assembly. Preprogrammed for use with IBT Board. Includes CASHMI PCB, 4 mounting screws, 16 ga. SS backing plate, membrane switches & gasket.
Direct Fired Air Movement Control Components
8164
[5 used]
1/4" Nylon Tubing - Used with the Modular Make-Up Air Units A1-D, A2-D, A3-D, A4-D, A5-D and the NHMUA1, NHMUA2, NHMUA3, AI (Price Per Foot). Type 12.
88130
[1 used]
1/4" Plastic Union Elbow for connecting airflow tubing to airflow probes (17045 & 17045A).
Direct Fired Sheet Metal Components
MD15LCOVER
[4 used]
Door Louver Cover for Commercial DF 1-5 Units.
MLIFTL
[6 used]
LIFTING LUG
Exhaust Fan Whiz Nuts & Bolts
0120763.0800
[8 used]
A0031100 - 1"L, 1/4-20 Matpoint, Self Aligning, Hex Head, Grade 5 Bolt
11626-03224
[8 used]
Cage Nut - 1/4" - 20. Installed in 1/2" square hole. Used on 20 gauge material.
5/16-18 WHIZNUT
[8 used]
Zinc-Plated Grade 5 Steel Serrated-Flange Locknut, 5/16"-18 Thread Size, 11/16" Flange Diameter, 9/32" Overall Height.
Exhaust Fan Wiring Options
8002
[28 used]
CONDUIT - 1/2" LT FLEX JIC. (Price per Foot)
Indirect Air Movement Control Components
RFS-4100-078
[1 used]
AIR FLOW SWITCH - Used for IBT air proving switch and clogged filter switch option. Factory set @ .25", adjustable.
NS2-1112-01
[1 used]
AIR FLOW SWITCH - Used with IBT units. Factory set @ .35". Induced draft fan airflow switch with bleed hole.
Indirect Fired Sheet Metal Components
IBT1HE200TF
[1 used]
IBT 1 HE 200 TOP FLASHING
IBT1HELFS
[1 used]
IBT 1 HE LEFT FLASHING SINGLE FURNACE
IBT1HERF
[1 used]
IBT 1 HE RIGHT FLASHING
IBT12SDSB
[1 used]
IBT 1-2 Averaging Sensor Bracket
IBT12HEBOTSD
[1 used]
IBT 1-2 HE BOTTOM SIDE DISCHARGE
IBT12HS
[4 used]
IBT 1-2 HORIZONTAL SUPPORT
IBT12LIDSF
[1 used]
IBT 1-2 LID SINGLE FURNACE
IBT12MR
[2 used]
IBT 1-2 MAIN RAIL
IBT14HEEF
[1 used]
IBT 1-4 HE END FLASHING
IBT15CBBT
[1 used]
IBT 1-5 CABINET BOTTOM
IBT15ELBK
[1 used]
IBT 1-5 ELECTRICAL BACK
IBT15ELSD
[2 used]
IBT 1-5 ELECTRICAL SIDE
IBT15ELTP
[2 used]
IBT 1-5 ELECTRICAL TOP
IBT15HC
[1 used]
IBT 1-5 HAT CHANNEL
IBT15TD
[1 used]
IBT 1-5 TIE DOWN
IBT15VFDB
[1 used]
IBT 1-5 VFD BACK
IBT15BDPN
[1 used]
IBT Burner Condensate Drip Pan
IBTHE200ADS
[1 used]
IBT HE 200 AIR DISTRIBUTION SCREEN
Indirect Flame Control Components
35-615937-997
[1 used]
24VAC Direct Spark Ignition Control. Combustion blower relay, 15 second trial for ignition, 60 second pre-purge and inter-purge, 120 second post-purge, 3 trials for ignition Recycle on loss of flame remote flame sense. Special extended flame integration time.
1-1437685-3-4
[1 used]
2TK2-48 Snap Track PVC Channel. 4 Inches Long.
Intakes & Accessories
DUCTBOARD
[1 used]
DUCTBOARD 4X10 SHEET Owens Corning Type 475FRK Insulation. 1 Sheet.
Miscellaneous Electrical Parts
CAT5_3FT
[1 used]
3 Foot Long CAT5 Cable
800041
[2 used]
Bolt Whiz 10-32 X 1/2, SFB103212Z, Steel Grade 5 Minimum (3 Evenly Spaced Radial Marks)
8012A
[3 used]
J-BOX - SWITCH BOX - CY X 1/2.
800030
[2 used]
Nut Whiz 10-32, SFLN1032Z, Steel, Large Flange
FSCWIREHARNESS
[1 used]
Wire Harness for IBT Board. 1 Required Per Furnace.
Miscellaneous Heater Components
3M467J
[1 used]
Captiveaire Factory Direct sticker
INSULATION/sq ft
[75 used]
INSULATION (Price per Sq Foot)
HG-OTA100
[12 used]
Removable Door Hinge used on Pollution Control Units and KB Blowers
Miscellaneous Hood Parts
SCREW 10-24X3/8 ZINC RD HD SLOTTED MS - DOOR HANDLE
[8 used]
SCREW 10-24X3/8 ZINC RD HD SLOTTED MS - Used on UC door handles and MUA door handles
104778
[1 used]
SEALANT - 10.3 oz Silicone Silver/Aluminum Sealant. 350 deg silicone used in hoods. (item #104778)
Pollution Control Gasket
397-91PSA-Foot
[1 used]
Gasketing - Thermeez Woven Ceramic Tape - 1/4" x 1" with adhesive back - Max Temp 1500°F. To be applied between fan base and grease duct. Per Foot.
Product Manuals
MANUAL INDIRECT BENT TUBE
[1 used]
Manual for Commercial Indirect Fired Bent Tube Heater
RTU Miscellaneous Components
A7-10-351-20
[6 used]
Black Compression Handle Latch and Clasp
Supply Fan Miscellaneous Parts
SB6-4-RIVET
[104 used]
RIVET - 3/16" Diameter, .126 To .250 Grip Range, SB6-4 Button Head Steel/Steel. Replaced 800075.
ITH41234
[10 used]
SHEET METAL SCREWS 12-14 X 3/4"
Supply Fan Sheet Metal Components
M1EFLS
[2 used]
1 END FLASHING
B1DDBAVP1618Z
[1 used]
A1 Direct Drive Blower Assembly Venturi Assembly Ziehl
B1DDCZ
[1 used]
A1 Direct Drive Collar Ziehl
B1DDDDLZ
[1 used]
A1 Direct Drive Down Discharge Liner Ziehl
B1DDWGZ
[1 used]
A1 Direct Drive Wheel Guard Ziehl
B1DDC
[1 used]
AHU 1 Direct Drive Discharge Collar
B1LIDDPRL
[1 used]
AHU 1 LID w/Intergrated Drip Rail
B1SDBKHDD
[1 used]
AHU 1 Side Discharge Back Hinged Direct Drive
MCONWAS
[2 used]
Connecting Washer 12 Gauge 2-7/8" x 2-7/8"
ME12MR
[2 used]
EC 1-2 MAIN RAIL 35.25X8 GALV14GA. Also used on Size 1 Blower.
B1G10COL
[1 used]
G10 COLLAR for size #1 heater.
M1HSUP
[3 used]
HORIZONTAL SUPPORT
MRDPLATE
[1 used]
Rotary Disconnect Plate for Supply Fans. 16 GA G90 Galvanized.
Supply Fan Vibration Isolators
L1VIB
[4 used]
Motor Frame Vibration Eliminator 1" Out. Dia. X 1/4" Tall, Rubber (Black) New Style, 5/16-18 x 1/2 dual studs. Durometer = 50
Thermostats/Sensors
A/CP-DO-240-QC
[1 used]
10K, Type II thermistor with 6" probe. 20' wire leads. (Replaces part# A/CP-DO-120-QC)
CP-HT-FA-12
[1 used]
High Temp 10K, Type II thermistor with average sensor wire 12' long operable up to 200F. No metal box included.
IBT Board
[1 used]
Staging and Modulating PCB for IBT heaters. Includes control of multiple furnaces, forced high fire, modulation. Used in conjunction with CAS HMI. Not a direct replacement for FVFAB.
Transformers
BE161640GEK0018
[1 used]
TRANSFORMER - Low 40VA Voltage Transformer Used for 120v Primary and 24v Secondary.
Transformers (Heater Parts)
BE141620GEK0032
[1 used]
TRANSFORMER - 120V-24V 20VA with QC's Prod. 50/60Hz
Curbs
Part
CRB21X71X6INS ROOF CURB - 21" Width, 71" Length, 6" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X8INS ROOF CURB - 21" Width, 71" Length, 8" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X10INS ROOF CURB - 21" Width, 71" Length, 10" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X12INS ROOF CURB - 21" Width, 71" Length, 12" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X16INS ROOF CURB - 21" Width, 71" Length, 16" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X18INS ROOF CURB - 21" Width, 71" Length, 18" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X20INS-BTC BOLT TOGETHER ROOF CURB -21" X 71" X 20" High, Insulated. 18 GA Galvanized. Ships Flat. Pitched Curb Option Not Available with Bolt Together Curbs.
CRB21X71X20INS ROOF CURB - 21" Width, 71" Length, 20" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X24INS CURB - 21" Width, 71" Length, 24" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X26INS CURB - 21" Width, 71" Length, 26" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X30INS CURB - 21" Width, 71" Length, 30" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X30.50INS CURB - 21" Width, 71" Length, 30.50" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X31.25INS CURB - 21" Width, 71" Length, 31.25" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X36INS CURB - 21" Width, 71" Length, 36" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X40INS ROOF CURB - 21" Width, 71" Length, 40" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X42INS ROOF CURB - 21" Width, 71" Length, 42" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X48INS ROOF CURB - 21" Width, 71" Length, 48" Supply Height, Insulated. For #1 Modular Heater.
CRB21X71X65INS ROOF CURB - 21" Width, 71" Length, 65" Supply Height, Insulated. For #1 Modular Heater. Horizontal panel seam placed in center of height.
Options
Part
CSMDTIL Commercial Smoke Detector Interlock (Detector By Others)
D4120-DST-1.5-C Duct Mounted Smoke Detector For Commercial Direct Fired Heater. Complete with detector (D4120) and sampling tube (DST-1.5). Ships Loose
Show parts
CABHTR100WNC Control panel enclosure heater, includes 100w, 120v heater. Recommended for winter design temperature less than 0°F. Operates on PCB controls in IBT Single Modules or RTU
Show parts
IBT Condensation Kit- 1 Factory Assembled IBT Condensation Drain Kit for 1 Furnace Units. Required for Winter Design Temp of 0 degrees F and lower. Kit includes drain assembly, mounting screws, zip ties, and heat tape for single furnace unit. Field piping from unit by others.
Show parts
CWCM1-2 CW Coil Module for Size 1 Modular Fans - 1,000 thru 3,250 CFM (5 Ton, 5WS1004B-31.5x27.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
CWCM1-4 CW Coil Module for Size 1 Modular Fans - 1,000 thru 3,250 CFM (12.5 Ton, 5WS1404B-31.5x27.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Ecoat-AC-1 Size 1 Cooling Coil Ecoating option for MPU-AC options. Adds 5-6 week lead time.
Ecoat-1-MPU-RH Size 1 Cooling Coil Ecoating option for MPU-RH options. Adds 5-6 week lead time.
Ecoat-1-C Size 1 Cooling Coil Ecoating option for standard MPU, DX and Chilled Water Coils. Adds 5-6 week lead time.
3 Ton 1 Phase 208/230V Condensing Package 3 Ton, Single Circuit Condensing Unit. 1 phase 208-230V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. 24ACC436A003
Show parts
3 Ton 208/230V Condensing Package 3 Ton, Single Circuit Condensing Unit. 3 phase 208/230V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. Shipping included in price. 24ABB336A005
Show parts
3 Ton 460V Condensing Package 3 Ton, Single Circuit Condensing Unit. 3 phase 460V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. 24ABB336A006
Show parts
3 Ton 575V Condensing Package 3 Ton, Single Circuit Condensing Unit. 3 phase 575V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. 24ABB336A001
Show parts
5 Ton 1 Phase 208/230V Condensing Package 5 Ton, Single Circuit Condensing Unit. 1 phase 208-230V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. 24ABB360A003
Show parts
5 Ton 208/230V Condensing Package 5 Ton, Single Circuit Condensing Unit. 3 phase 208/230V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. 24ABB360A005
Show parts
5 Ton 460V Condensing Package 5 Ton, Single Circuit Condensing Unit. 3 phase 460V. Air Cooled. Includes: Disconnect Switch. R410A refrigerant and piping by others. 24ABB360A006
Show parts
DXM1-3 DX Coil Module for Size 1 Modular Fans - 2,000 thru 3,250 CFM (10 Ton - 2 Circuit DX Coil, 4EZ0903H-31.5x27.0) NOT BUILT WITH OPP SIDE CONTROLS. DXM1-3 Condenser and condenser disconnect (unless provided on quote) will be installed, started and warranted by others. R410A refrigerant and piping by others. Ensure DX-Kit is ordered for filter drier, sight glass, thermal expansion valve. (Old Heatcraft Coil # 5EJ0804B-31.5x27.0)
Show parts
ECM Wiring Package- RTC (1PH-Ziehl) ECM Wiring Package and Manual or 0-10 VDC Control for Supply EC Single Phase Ziehl Fans. RTC Controller
Show parts
ECM Wiring Package- RTC (Ziehl) ECM Wiring Package and Manual or 0-10 VDC Control for Supply EC Ziehl Fans. RTC Controller
Show parts
ECM Wiring Package- ECPM03 (1PH-Ziehl) ECM Wiring Package-Supply - PWM Signal from ECPMO3 Prewire (1 - Phase Ziehl Motor)
Show parts
ECM Wiring Package- ECPM03 (Ziehl) ECM Wiring Package-Supply - PWM Signal from ECPMO3 Prewire (3 - Phase Ziehl Motor)
Show parts
IBT-EC-FPDK-Evap Freeze Protection Drain Control kit for Evaporative Coolers. Includes 3-Way water solenoid valve 8316G064 (shipped loose), Pressure switch installed upstream of 2way solenoid in unit, Brass Tee and 2 NPT half inch nipples. Field wiring required by others for 3-way valve. For both Celdek and Standard V-bank type Configurations.
Show parts
CD-G-24x20x12 Glasdek Media for size 1 celdek evaporative cooler intake. 24in wide x 20in tall x 12in thick.
CD-G-32x25x12 Glasdek Media for size 2 celdek evaporative cooler intake. 32in wide x 25in tall x 12in thick.
PRESSGA35 Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size
PRESSGA-0-10 Gas Pressure Gauge, 0 to +10 Inches Wc., 2.5" Diameter, 1/8" Thread Size, Rear Thread
143-80-2-3/4-G-5/8 Gas regulator - 3/4" diameter thread size, 10 PSI Inlet Gas Pressure. 1020 CFH, 6" - 14" Outlet Pressure. Includes 143-62-021-17 "Green" spring and 5/8" 10 PSI orifice.
HGP-A-1 High Pressure Gas Switch (2" - 16" WC) Factory set at 5" w.c. (Natural) or 12" w.c. (L.P.) 1 Switch for Indirects with 1 Furnace.
Show parts
LGPSO Low Pressure Gas Switch (1" - 6" WC) Factory set at 2" w.c.
Show parts
MIAMI-DADE NOA-2 Supply Miami Dade Impact and Wind Load Certification +30 / -130 PSF - Miami Dade County Product Control Approved. Florida Building Code approval. Roof Mount Exhaust Curbs up to 20" high must be 18 gauge Aluminized.
Single Point Connection - 1 Single Point Electrical Connection for all IBT Heaters with 1 module. QNTY 1 750va Transformer Used. If a Non-DCV Prewire is used on the IBT Heater, the #28, #47, "MA", or "E2" Option Prewire must be selected. Do not provide supply starter in prewire.
Separate 120V Connection - 1 Separate 120V Electrical Connection for all IBT Heaters with 1 module for Standing power. 120V must be run by electrician from building panel to mua switch.
IBT EVAP INTERLOCK Layer Control for IBT Evap
Show parts
IBT ROOM OVERRIDE Option Control for IBT/RTU Scheduling. Do not order as a part.
IFHIELOR Specially sized orifices for applications above 2,000', notify engineering.
Show parts
IHC-IDF1 Indoor Hanging Cradle For The Size 1 Indirect Fired Unit. 2 HSA200 Hanging Isolators per Uni-Strut Included.
Show parts
Blower Delay Start Blower Delay Start. Allows Indirect Furnace to pre-heat before blower operation. Factory set at 90 seconds. TI-11 set at 20 seconds. TI-12 set at 90 seconds.
Burner-Interlock-IBT/RTU Burner Interlock Input. Locks out cooling when interlock is energized.
CLCOMM_REV04 CASLink building monitoring system communications module. Requires internet & field wired ethernet connection or 3G cellular service. Includes Rev 3 Comm Module, RJ45 to modbus converter, 3 FT cat5 cable, and 1 FT of shielded twisted pair.
Show parts
AC-Interlock-IBT/RTU Cooling Interlock Input to PCB Board. Locks out burner circuit when AC is energized.
DDC-IP BACnet Monitoring Remote IP BACnet monitoring for supply fans.
Show parts
DDC-LONWorks Monitoring Remote LONWorks monitoring for supply fans.
Show parts
DDC-MSTP BACnet Monitoring IBT Remote MSTP BACnet monitoring for IBT
Show parts
FECONTAAFS Field Wired Exhaust Contactor After Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP 230v, 15HP max. 460V, 15HP max. 575V or (4) Dry Interlocks. Overload not Included
Show parts
FECONTBAFS Field Wired Exhaust Contactor Before Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP max 230v, 15HP max. 460V. Overload not Included
Show parts
EXHSTARTER1-3AAFS Exhaust Fan Starter Installed in size 1, 2, or 3 heater powered after airflow swtich
EXHSTARTER1-3BAFS Exhaust Fan Starter Installed in size 1, 2, or 3 heater powered before airflow switch
Exhaust on Fire Exhaust on Fire
OCCUPIED SCHEDULING Occupied Scheduling Defaulted for IBT/RTU.
OPPSIDE-H-CTRLS Mount motor and controls on opposite side of heater.
Supply Fan Preset Speed Supply Fan Preset Speed Input to PCB. Field Wired.
UNOCCUPIED SCHEDULING Unoccupied Scheduling Defaulted for IBT/RTU.
CLOGFILTHMI Clogged Filter Switch with Notification on HMI
Show parts
CVOUTLET GFCI 15 amp Convenience Outlet For Heater Enclosure. Power supply by others - Includes receptacle and J box.
EXTENDED-DROP Extended Drop for Commercial Heaters and Supply Fans. Extends the power and remote panel connections to the unit to 20' of total length.
CVOUTLET6IBT1 GFCI 6 amp Powered Convenience Outlet For IBT 1 units with 208/230/460 power. Includes receptacle, jbox, cover, and transformer.
Show parts
Single Electrical Cabinet LED Lights Single Electrical Cabinet LED Lights Used on Modular MUA Units
Show parts
MB1-MPU Support shell for Size 1 Modular Package Unit. Includes control vestibule. Includes condenser supports. Does not include return air or inlet air damper.
Show parts
MB1-IBT-SCHEDULE Mixing Box for Size 1 IBT. Actuator Control By Schedule.
Show parts
MB1-IBT-Analog Mixing Box for Size 1 IBT. Actuator Control By 0-10V Input to IBT Board by others.
Show parts
MB1-IBT-2P Mixing Box for Size 1 IBT. Actuator Control By Field Wired Switch.
Show parts
MB1-IBT-MAN Mixing Box for Size 1 IBT. Actuator Control By 0-10V Output on IBT Board.
Show parts
MB1-IBT-OA Mixing Box for Size 1 IBT. Actuator Control By 0-10V Output On IBT Board to Maintain Desired Outdoor Air %.
Show parts
MB1-SP Mixing Box for Size 1 Modular Supply Fan. Actuator Control by Static Pressure. Photohelic included.
Show parts
A1IBTUPDISCH Up Discharge Construction Size 1 IBT
Show parts
A1-D-MBDD INS Motorized Back Draft Insulated Damper 16" X 18" for Size 1 Standard & Modular Heater Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, TFB120S Actuator Included. Insulted blades and frame. Thermally broken blades.
Show parts
A1-D-MBDD Motorized Back Draft Damper 16" X 18" for Size 1 Standard & Modular Heater Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, TFB120S Actuator Included
Show parts
A1-MBDD-SL Motorized Back Draft Discharge Damper Shipped Loose 22.75" X 24" for Size 1 Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, LF120-S Actuator Included, Field Installation Required. Damper, actuator & actuator cover (p/n ACTCOVERMOD) factory assembled.
Show parts
Full Crating for Heater Full crating for commercial heaters for shipping.
ENAM-1 Tan Enamel Coating (exterior walls/roof) For Heaters with 7"-15" blower wheels, includes casing and intakes. Consult factory for other colors. Sherwin Williams p/n F75KXN5809-4347, (AX = A0006229)
Condenser_Locking_Caps_2 Locking caps for double condenser units. Consists of 4 locking caps, part# NCP-4, and 1 key, part# NC-KEY.
Show parts
Condenser_Locking_Caps_1 Locking caps for single condenser units. Consists of 2 locking caps, part# NCP-4, and 1 key, part# NC-KEY.
Show parts
DX 1-1 KIT-R410A DX 1-1 Kit R410A. Single Circuit, 3 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
DX 1-2 KIT-R410A DX 1-2 Kit R410A. Single Circuit 5 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
DX 1-3 KIT-R410A DX 1-3 Kit R410A. Dual Circuit 10 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
DX 1-4 KIT-R410A DX 1-4 Kit R410A. Dual Circuit 12.5 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
ShipLoose-1C-1PH Ship Condenser Loose - Single Condenser, Single Phase - Condenser Disconnect Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
ShipLoose-1C-3PH Ship Condenser Loose - Single Condenser, Three Phase - Condenser Disconnect Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
ShipLoose-2C-1PH Ship Condensers Loose - Two Condensers, Single Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
ShipLoose-2C-3PH Ship Condensers Loose - Two Condensers, Three Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
SP-MPU-1C Single Point MPU Connection, 1 Condenser.
Show parts
SP-MPU-2C Single Point MPU Connection, 2 Condensers.
Show parts
MELIM-1 Size 1 Moisture Eliminator Option for DX Coils, MPUs and Chilled Water Coils - allows cooling coil face velocity to increase to 650 fpm. Increases cooling coil max cfm to 3650 cfm.
Show parts
MPU1-RH Size 1 MPU Reheat Option. Reheat uses warm liquid refrigerant. Reheat runs continuously in stage 1 circuit. Option should not be used if entering air dew point is below 65 degrees F. Nominal capacity 7.6 MBH. Increases max CFM to 1460.
Show parts
MELIM-1-AC Size 1 MPU-AC Moisture Eliminator Option - allows cooling coil face velocity to increase to 650 fpm. Increases cooling coil max cfm to 1450 cfm.
Show parts
Damper Presets Damper Preset Position Input to PCB. Field Wired.
Show parts
D-Hanger Curb Duct Hanger - 1-1/4" Angle Iron Frame Welded to Curb to support standard size ductwork. Priced per curb. Only available when curb assembly is ordered.
MB1-MERV 13-EXTRA Extra set of MERV 13 filters for Size 1 Mixing Box. Uses 5 10 x 16 x 2 inch filters.
Show parts
MB1-MERV 13 MERV 13 filter option for Size 1 Mixing Box or Condenser Support. Mixing Box or Condenser Support must be selected for this option. Uses 5 10 x 16 x 2 inch filters.
Show parts
MB1-MERV 8 MERV 8 filter option for Size 1 Mixing Box or Condenser Support. Mixing Box or Condenser Support must be selected for this option. Uses 5 10 x 16 x 2 inch filters.
Show parts
Dedicated Combustion 8 inch Round Take-Off Installed in Lid of IBT for dedicated combustion air on indoor units. Control side door constructed without louvers. All combustion ductwork by others.
Show parts
Ship Modules Separate Ship Modules Separate Option for Modular Units
MB1-TOPRN Top Return Option for Size 1 Mixing Box - No Filter Option Available. Use top return lid and standard DF base.
Show parts
FIRESTAT-DISCHARGE- Discharge Firestat. Set to 240°F
FREEZESTAT- Freezestat factory set at 35°F and 10 minutes.
IBT12 Side Discharge Used with size 1 and size 2 side discharge IBT modules.
Show parts
FIRESTAT-INTAKE- Intake Firestat. Set to 135°F
IBT/DF/RTU Nema 4x remote Space Sensor Nema 4x Remote Room Sensor Option. Wall Mountable 10k Room Sensor Included.
Show parts
IBT/RTU remote Space Sensor Remote Room Sensor Option. Wall Mountable 10k Room Sensor Included.
Show parts
Blower Delay Stop Blower Delay Stop. Allows supply fan to run after the burner has shut off Factory set at 90 secs for indirect 30 secs for direct.
VBI-CSF "Insulation" for V-bank Intake Option.
VB-DS-MB1 V-bank Downstream of Mixing-Box Option Size 1
DCVWP-SUPPLY Separate 120VAC Wiring Package for Make-Up Air Units. Option must be selected when mounting VFD in prewire panel or with DCV package. Provides separate 120VAC input to supply fan. This 120V signal must be run by electrician from DCV to mua switch.
Show parts
VAV-WP-VDC-INPUT-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. 0-10VDC Speed Control Variable Frequency Drive Included
VAV-WP-BSPC-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Building Static Pressure Variable Frequency Drive Control Included
Show parts
VAV-WP-MC-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Manual Speed Control Variable Frequency Drive Included
VFDINUNIT VFD factory mounted and wired in unit control vestibule.
 
 
 

Security Policy     Privacy Policy     Legal Notice     Warranty     Return Policy