T-A3-24D Parts
Motors, Pulleys, & Motor Specific Parts
Motor HP Phs Voltage FLA Shaft Frame Weight RPM Vendor
DTP0026 2.000 3 208-230/415/460 V 8.3-7.5/3.1/3.8 1.125" 184T 68 lbs 1150 Mimco/TECO
ODP, Premium (E-Plus3) Eff.  
Show parts
DTP0034 3.000 3 208-230/380/415/460 V 9.5-8.6/5.2/4.8/4.3 1.125" 182T 69 lbs 1755 Mimco/TECO
ODP, Premium (E-Plus3) Eff.  
Show parts
DTP0034-50HZ 3.000 3 190/208-220-230/380/415 V 10.4/9.8-9.2-9.2/5.2/4.9 1.125" 182T 69 lbs 1438 Mimco/TECO
ODP, Premium (E-Plus3) Eff.  
Show parts
DTP0036 3.000 3 208-230/380/460 V 10.2-9.2/5.4/4.6 1.375" 213T 120 lbs 1150 Mimco/TECO
ODP, Premium (E-Plus3) Eff.  
Show parts
00312OT3H213T-S 3.000 3 575 V 3.3 1.375" 213T 104 lbs 1150 WEG
ODP, Premium (E-Plus3) Eff.  
Show parts
00318OT3H182T-S 3.000 3 575 V 3 1.125" 182T 66 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff.  
Show parts
00518OT3H184T-S 5.000 3 575 V 5 1.125" 184T 80 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff.  
Show parts
00512OT3H215T-S 5.000 3 575 V 5.4 1.375" 215T 124 lbs 1150 WEG
ODP, Premium (E-Plus3) Eff.  
Show parts
DTP0054 5.000 3 190/200-208-230/380/400/415/460 V 17/15.6-15-13.6/8.5/7.7/7.5/6.8 1.125" 184T 77 lbs 1750 Mimco/TECO
ODP, Premium (E-Plus3) Eff.  
Show parts
DTP0054-50 5.000 3 190/208-230/380/415 V 14.9/15-13.6/7.5/8.1 1.125" 182T 89 lbs 1435 Mimco/TECO
ODP, Premium (E-Plus3) Eff.  
Show parts
DTP0056 5.000 3 208-230/380/415/460 V 15.8-14.3/8.4/8/7.2 1.375" 215T 123 lbs 1150 Mimco/TECO
ODP, Premium (E-Plus3) Eff.  
Show parts
DTP7/54 7.500 3 200-208-230/380/400/460 V 21.5-21.1-19.1/11.4/10.8/9.6 1.375" 213T 104 lbs 1750 Mimco/TECO
ODP, Premium (E-Plus3) Eff.  
Show parts
DTP7/54-50 7.500 3 190/208-230/380/415 V 22.9/21.1-19.1/11.5/10.7 1.375" 213T 158 lbs 1470 Mimco/TECO
ODP, Premium (E-Plus3) Eff.  
Show parts
DTP0104 10.000 3 190/208-230/380/460 V 29.9/27-24.4/15/12.2 1.375" 215T 143 lbs 1755 Mimco/TECO
ODP, Premium (E-Plus3) Eff.  
Show parts
DTP0104-50 10.000 3 190/380/415 V 30/15/13.7 1.375" 215T 143 lbs 1436 Mimco/TECO
ODP, Premium (E-Plus3) Eff.  
Show parts
01018OT3H215T-S 10.000 3 575 V 9.9 1.375" 215T 137 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff.  
Show parts
00212ET3E184T-W22 2.000 3 208-230/460 V 7.2-6.5/3.3 1.125" 182T 99 lbs 1150 WEG
TEFC, Premium (E-Plus3) Eff.  
Show parts
00318ET3H182T-W22 3.000 3 575 V 3.1 1.125" 182T 94 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff.  
Show parts
GP0034 3.000 3 190/208-230/380/400/460 V 9.8/9.4-8.5/4.9/4.6/4.3 1.125" 182T 60 lbs 1800 Mimco/TECO
TEFC, Premium (E-Plus3) Eff.  
Show parts
GP0034-50 3.000 3 190/380 V 9.9/4.9 1.125" 182T 60 lbs 1440 Mimco/TECO
TEFC, Premium (E-Plus3) Eff.  
Show parts
GP0054 5.000 3 190/200-208-230/380/400/460 V 15.6/14.9-14.5-13.1/7.8/7.4/6.6 1.125" 184T 82 lbs 1800 Mimco/TECO
TEFC, Premium (E-Plus3) Eff.  
Show parts
GP0054-50 5.000 3 190/220/380 V 15.9/15.9/7.9 1.125" 184T 82 lbs 1440 Mimco/TECO
TEFC, Premium (E-Plus3) Eff.  
Show parts
00518ET3H184T-W22 5.000 3 575 V 5.1 1.125" 184T 104 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff.  
Show parts
GP0104 10.000 3 190/200-208-230/380/400/460 V 29.6/27.8-26.6-24/14.8/13.9/12 1.375" 215T 159 lbs 1755 Mimco/TECO
TEFC, Premium (E-Plus3) Eff.  
Show parts
GP0104-50 10.000 3 190/380 V 29.7/14.9 1.375" 215T 159 lbs 1440 Mimco/TECO
TEFC, Premium (E-Plus3) Eff.  
Show parts

The manufacturer reserves the right to use alternate motors from alternate vendors that meet the operating requirements of the fan but may have slightly different specifications.
Intakes & Intake Parts
Part
CD-VB-O-03M-HE Celdek and V-Bank for Size # 3 Modular Supply unit with HE filters. For outdoor installation. MERV 15 V-Bank Filters. Includes Screened Intake
Show parts
CD-VB-O-03M-HE-IL Celdek and V-Bank for Size # 3 Modular Supply unit with HE filters. For outdoor installation. MERV 15 V-Bank Filters. Includes Intake Louver.
Show parts
CD-VB-I-03M-HE Celdek and V-Bank for Size # 3 Modular Supply unit with HE filters. For indoor installation. MERV 15 V-Bank Filters.
Show parts
CD-VB-O-03M-HEPA Celdek and V-Bank for Size # 3 Modular Supply unit with HEPA filters. For outdoor installation. Includes Screened Intake
Show parts
CD-VB-O-03M-HEPA-IL Celdek and V-Bank for Size # 3 Modular Supply unit with HEPA filters. For outdoor installation. Includes Intake Louver.
Show parts
CD-VB-I-03M-HEPA Celdek and V-Bank for Size # 3 Modular Supply unit with HEPA filters. For indoor installation.
Show parts
CD-VB-I-03M-TA Celdek and V-Bank for Size # 3 Modular Supply unit with TA filters. For indoor installation. MERV 8 V-Bank Filters.
Show parts
CD-VB-O-03M-TA Celdek and V-Bank for Size # 3 Modular Supply unit with TA filters. For outdoor installation. MERV 8 V-Bank Filters. Includes Screened Intake
Show parts
CD-VB-O-03M-TA-13-IL Celdek and V-Bank for Size # 3 Modular Supply unit with TA filters. For outdoor installation. MERV 13 V-Bank Filters. Includes Intake Louver.
Show parts
CD-VB-O-03M-TA-IL Celdek and V-Bank for Size # 3 Modular Supply unit with TA filters. For outdoor installation. MERV 8 V-Bank Filters. Includes Intake Louver.
Show parts
CD-VB-I-03M-TA-13 Celdek and V-Bank for Size # 3 Modular Supply unit with TA filters. For indoor installation. MERV 13 V-Bank Filters.
Show parts
CD-VB-O-03M-TA-13 Celdek and V-Bank for Size # 3 Modular Supply unit with TA filters.For outdoor installation. MERV 13 V-Bank Filters. Includes Screened Intake
Show parts
CD-VB-I-03M Celdek and V-Bank for Size # 3 Modular Supply unit. For indoor installation.
Show parts
CD-VB-O-03M Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
CD-VB-O-03M-IL Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
CD-I A3 Celdek Evaporative Cooler for Size # 3 Modular Un-tempered Supply Air unit. 40.75" Wide x 38.125" Long x 43.375" High. For indoor installation. Min. water pressure for optimal performance is 30 PSI. Max. water pressure should not exceed 50 PSI. Use with water softener recommeded.
Show parts
CD-O A3 Celdek Evaporative Cooler for Size # 3 Modular Un-tempered Supply Air Unit. 40.75" Wide x 72.313" Long x 43.375" High. Includes screened intake. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A3-IH Celdek Evaporative Cooler for Size # 3 Modular Un-tempered Supply Air unit. 40.75" Wide x 83.75" Long x 43.375" High. Includes intake hood with filters. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A3-NF Celdek Evaporative Cooler for Size # 3 Modular Un-tempered Supply Air unit. 40.75" Wide x 83.75" Long x 43.375" High. Includes intake hood without filters. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A3-IL Celdek Evaporative Cooler for Size # 3 Modular Un-tempered Supply Air Unit. 40.75" Wide x 72.313" Long x 43.375" High. Includes intake louver. For outdoor installation. Use with water softener recommended.
Show parts
SI-3 Screen Intake for Size 3 Commercial Fans.
Show parts
CD-O A4-IH-3 Size # 4 Celdek Evaporative Cooler for Size # 3 Modular Make Up Air unit. 47.813" Wide x 110.238" Long x 51.375" High. Includes intake hood with filters. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A4-NF-3 Size # 4 Celdek Evaporative Cooler for Size # 3 Modular Make Up Air unit. 47.813" Wide x 110.238" Long x 51.375" High. Includes intake hood without filters. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A4-3 Size # 4 Celdek Evaporative Cooler for Size # 3 Modular Make Up Air unit. 47.813" Wide x 82.5" Long x 51.375" High. Includes screened intake. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A4-3-IL Size # 4 Celdek Evaporative Cooler for Size # 3 Modular Make Up Air unit. 47.813" Wide x 82.5" Long x 51.375" High. Includes intake louver. For outdoor installation. Use with water softener recommended.
Show parts
CD-I A4-3 Size 4 Celdek Evaporative Cooler for Size # 3 Modular Make Up Air unit. 47.813" Wide x 35.188" Long x 51.375" High. For indoor installation. Min. water pressure for optimal performance is 30 PSI. Max. water pressure should not exceed 50 PSI. Use with water softener recommended.
Show parts
CD-TL-O A4-3 Size 4 Celdek Evaporative Cooler for Size # 3 Modular Make Up Air unit. 47.813" Wide x 82.5" Long x 51.375" High. Includes screened intake. For outdoor installation. Use with water softener recommended.
Show parts
CD-LPD-VB-O-04-3M-TA-13 Size 4 LPD Celdek and V-Bank for Size # 3 Modular Make Up Air unit. For outdoor installation. Includes Screened Intake
Show parts
CD-LPD-VB-O-04-3M-TA-13-IL Size 4 LPD Celdek and V-Bank for Size # 3 Modular Make Up Air unit. For outdoor installation. Includes Intake Louver.
Show parts
CD-LPD-VB-I-04-3M-TA-13 Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For indoor installation.
Show parts
CD-LPD-VB-I-04-3M-TA Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For indoor installation.
Show parts
CD-LPD-VB-I-04-3M Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For indoor installation.
Show parts
CD-LPD-VB-IH-O-04-3M-TA Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Intake Hood with 2" EZ filters
Show parts
CD-LPD-VB-O-04-3M-HEPA Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
CD-LPD-VB-O-04-3M Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
CD-LPD-VB-O-04-3M-TA Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
CD-LPD-VB-O-04-3M-HE Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Screened Intake
Show parts
CD-LPD-VB-O-04-3M-IL Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
CD-LPD-VB-O-04-3M-HE-IL Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
CD-LPD-VB-O-04-3M-HEPA-IL Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
CD-LPD-VB-O-04-3M-TA-IL Size 4 LPD Celdek and V-Bank for Size # 3 Modular Supply unit. For outdoor installation. Includes Intake Louver.
Show parts
SFIH-03M Sloped Filtered Intake for Size #3 Modular Untempered Make-Up Air Units. ~ 37.25" Wide X 51.625" Long X 35.188" High. Includes 2" MV EZ Kleen Metal Mesh FIlter.
Show parts
TL-03M TRUNKLINE - Extended Intake for size 3, modular untempered MUA unit, 35.25" Width, 126.63" Length, 33.19" Height Includes intake hood with 2" EZ Kleen metal mesh filters, adjustable legs and 74.75" long extension.
Show parts
VB-O-03M-HE V-Bank for Size # 3 Modular Make-Up Air unit with HE Filters. Includes screened intake. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
VB-O-03M-HE-IL V-Bank for Size # 3 Modular Make-Up Air unit with HE Filters. Includes intake louver. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
VB-O-03M-HEPA V-Bank for Size # 3 Modular Make-Up Air unit with HEPA filters. Includes screened intake. For outdoor installation.
Show parts
VB-O-03M-HEPA-IL V-Bank for Size # 3 Modular Make-Up Air unit with HEPA filters. Includes intake louver. For outdoor installation.
Show parts
VB-O-03M-TA V-Bank for Size # 3 Modular Make-Up Air unit with TA Filters. Includes screened intake. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
VB-O-03M-TA-13-IL V-Bank for Size # 3 Modular Make-Up Air unit with TA Filters. Includes intake louver. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
VB-O-03M-TA-IL V-Bank for Size # 3 Modular Make-Up Air unit with TA Filters. Includes intake louver. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
VB-O-03M-TA-13 V-Bank for Size # 3 Modular Make-Up Air unit with TA Filters. Includes screened intake. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
VB-O-03M V-Bank for Size # 3 Modular Make-Up Air unit. EZ Metal Mesh Filters. Includes screened intake. For outdoor installation.
Show parts
VB-O-03M-IL V-Bank for Size # 3 Modular Make-Up Air unit. EZ Metal Mesh Filters. Includes intake louver. For outdoor installation.
Show parts
VB-I-03M-HE V-Bank for Size # 3 Modular Supply unit with HE filters. For indoor installation. MERV 15 V-Bank Filters.
Show parts
VB-I-03M-HEPA V-Bank for Size # 3 Modular Supply unit with HEPA filters. For indoor installation.
Show parts
VB-I-03M-TA V-Bank for Size # 3 Modular Supply unit with TA filters. For indoor installation. MERV 8 V-Bank Filters.
Show parts
VB-I-03M-TA-13 V-Bank for Size # 3 Modular Supply unit with TA filters. For indoor installation. MERV 13 V-Bank Filters.
Show parts
VB-I-03M V-Bank for Size # 3 Modular Supply unit. EZ Metal Mesh Filters. For indoor installation.
Show parts
VB-O-03M-TA-13-IH-EZ V-Bank for Size #3 Modular Indirect-Fired Heater with TA Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
VB-O-03M-HE-IH-EZ V-Bank for Size #3 Modular Make-Up Air unit with HE Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 15 V-Bank Filters.
Show parts
VB-O-03M-HEPA-IH-EZ V-Bank for Size #3 Modular Make-Up Air unit with HEPA filters. Includes intake hood with EZ filters. For outdoor installation.
Show parts
VB-O-03M-TA-IH-EZ V-Bank for Size #3 Modular Make-Up Air unit with TA Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
Replacement Parts
Part
33008
[4 used]
A0003208 - 3/8" WASHERS
8003
[3 used]
CONDUIT CONNECTOR - 90deg; 1/2" Bridgeport, 1/2" long thread
MLIFTL
[4 used]
LIFTING LUG
F5020024MUSBI
[1 used]
USBI24 - Spun Inlet.
800113-D80
[6 used]
Motor Frame Vibration Eliminator 1 3/8 Out. Dia. X 3/4" Tall, Rubber (Black with Marking) New Style, Shear 45 lbs, Compression 100 lbs. 3/8-16 x 5/8 dual studs. Durometer = 80
800043
[8 used]
A0005678 - Bolt Whiz 3/8-16 X 1 1/2, Steel Grade 5 Minimum (3 Evenly Spaced Radial Marks)
11626-03224
[6 used]
Cage Nut - 1/4" - 20. Installed in 1/2" square hole. Used on 20 gauge material.
5/16-18 WHIZNUT
[8 used]
Zinc-Plated Grade 5 Steel Serrated-Flange Locknut, 5/16"-18 Thread Size, 11/16" Flange Diameter, 9/32" Overall Height.
8002
[12 used]
CONDUIT - 1/2" LT FLEX JIC. (Price per Foot)
DUCTBOARD
[2 used]
DUCTBOARD 4X10 SHEET Owens Corning Type 475FRK Insulation. 1 Sheet.
800041
[2 used]
Bolt Whiz 10-32 X 1/2, SFB103212Z, Steel Grade 5 Minimum (3 Evenly Spaced Radial Marks)
800030
[2 used]
Nut Whiz 10-32, SFLN1032Z, Steel, Large Flange
NBB4000516
[6 used]
5/16" NUTS
WA4000516
[10 used]
5/16" WASHERS
3M467J
[1 used]
Captiveaire Factory Direct sticker
HG-OTA100
[4 used]
Removable Door Hinge used on Pollution Control Units and KB Blowers
SCREW 10-24X3/8 ZINC RD HD SLOTTED MS - DOOR HANDLE
[4 used]
SCREW 10-24X3/8 ZINC RD HD SLOTTED MS - Used on UC door handles and MUA door handles
104778
[1 used]
SEALANT - 10.3 oz Silicone Silver/Aluminum Sealant. 350 deg silicone used in hoods. (item #104778)
90272A836
[16 used]
Zinc-Plated Steel Pan Head Phillips Machine Screw, 10-32 Thread, 1-1/2" Length Old AX # A0026555
90272A829
[8 used]
Zinc-Plated Steel Pan Head Phillips Machine Screw, 10-32 Thread, 1/2" Length
MANUAL UNTEMP
[1 used]
Manual for Commercial Supply Fan
A7-10-351-20
[4 used]
Black Compression Handle Latch and Clasp
2T4000516040000
[2 used]
5/16" BOLTS 4" LONG
SB6-4-RIVET
[116 used]
RIVET - 3/16" Diameter, .126 To .250 Grip Range, SB6-4 Button Head Steel/Steel. Replaced 800075.
ITH41234
[10 used]
SHEET METAL SCREWS 12-14 X 3/4"
B3DDBAVP
[1 used]
AHU 3 Direct Drive Blower Assembly Venturi Plate
B3DDC
[1 used]
AHU 3 Direct Drive Discharge Collar
B3DDDDL
[1 used]
AHU 3 Direct Drive Down Discharge Bottom Liner
B3DDMM
[1 used]
AHU 3 Direct Drive Motor Mount
B3DDMMS
[1 used]
AHU 3 Direct Drive Motor Mount Support
B3DDWG
[1 used]
AHU 3 Direct Drive Wheel Guard
B3LIDDPRL
[1 used]
AHU 3 LID w/Intergrated Drip Rail
B3MNRL
[2 used]
AHU 3 MAIN RAIL
B3SDBKHDD
[1 used]
AHU 3 Side Discharge Back Hinged Direct Drive
M3EFLS
[2 used]
END FLASHING 37.9375X8 GALV18GA REV1
M3HSUP
[3 used]
HORIZONTAL SUPPORT
B3ULLD
[1 used]
Lid Liner Blank for use with AHU-3 Insulation Liner Option.
Curbs
Part
CRB35X8 ROOF CURB - 35" Square X 8" High.
CRB35X10 ROOF CURB - 35" Square X 10" High.
CRB35X12 ROOF CURB - 35" Square X 12" High.
CRB35X14 ROOF CURB - 35" Square X 14" High.
CRB35X15 ROOF CURB - 35" Square X 15" High.
CRB35X16 ROOF CURB - 35" Square X 16" High.
CRB35X20 ROOF CURB - 35" Square X 20" High
CRB35X20-BTC BOLT TOGETHER ROOF CURB -35" Square X 20" High, 18 GA Galvanized. Ships Flat. Pitched Curb Option Not Available with Bolt Together Curbs.
Options
Part
D4120-DST-1.5-C Duct Mounted Smoke Detector For Commercial Direct Fired Heater. Complete with detector (D4120) and sampling tube (DST-1.5). Ships Loose
Show parts
CWCM3-1 CW Coil Module for Size 3 Modular Fans - 3,000 thru 7,000 CFM (10 Ton, 5WS0604B-43.5x42.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
CWCM3-2 CW Coil Module for Size 3 Modular Fans - 3,000 thru 7,000 CFM (15 Ton, 5WS1004B-43.5x42.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
CWCM3-3 CW Coil Module for Size 3 Modular Fans - 3,000 thru 7,000 CFM (20 Ton, 5WS1204B-43.5x42.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
CWCM3-4 CW Coil Module for Size 3 Modular Fans - 3,000 thru 7,000 CFM (25 Ton, 5WS1404B-43.5x42.0) Not stocked. Allow 5-6 weeks lead time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
Ecoat-AC-3 Size 3 Cooling Coil Ecoating option for MPU-AC options. Adds 5-6 week lead time.
Ecoat-3-MPU-RH Size 3 Cooling Coil Ecoating option for MPU-RH options. Adds 5-6 week lead time.
Ecoat-3-C Size 3 Cooling Coil Ecoating option for standard MPU, DX and Chilled Water Coils. Adds 5-6 week lead time.
Ecoat-3-H Size 3 Heating Coil Ecoating option for Hot Water and Steam Coils. Adds 5-6 week lead time.
A25SDAD-A 180° Side Discharge Air Diffuser A25. For Commercial Fans.
A18DDAD3W-A 3-Way Down Discharge Air Diffuser A18. For Commercial Fans.
A18DDAD4W-A 4-Way Down Discharge Air Diffuser A18. For Commercial Fans.
A18DDAD-A 45° Down Discharge Air Diffuser A18. For Commercial Fans.
Show parts
DXM3-1 DX Coil Module for Size 3 Modular Fans - 3,000 thru 7,000 CFM (10 Ton - 2 Circuit DX Coil, 4EZ0602H-43.5x42.0) NOT BUILT WITH OPP SIDE CONTROLS. DXM3-1 Condenser and condenser disconnect (unless provided on quote) will be installed, started and warranted by others. R410A refrigerant and piping by others. Ensure DX-Kit is ordered for filter drier, sight glass, thermal expansion valve. (Old Heatcraft Coil # 5EJ0603B-43.5x42.0)
Show parts
EC-FPDK-Evap Freeze Protection Drain Control kit for Evaporative Coolers. Includes 3-Way water solenoid valve 8316G064 (shipped loose), Pressure switch installed upstream of 2way solenoid in unit, Brass Tee, 2 NPT half inch nipples, and two stage thermostat T678A1361. Field wiring required by others for 3-way valve. For both Celdek and Standard V-bank type Configurations.
Show parts
CD-G-36x30x12 Glasdek Media for size 3 celdek evaporative cooler intake. 36in wide x 30in tall x 12in thick.
CD-G-43x38x12 Glasdek Media for size 4 celdek evaporative cooler intake. 43in wide x 38in tall x 12in thick.
UFEC 120V Wiring connection to energize evaporative coolers from untempered supply fans.
MIAMI-DADE NOA-2 Supply Miami Dade Impact and Wind Load Certification +30 / -130 PSF - Miami Dade County Product Control Approved. Florida Building Code approval. Roof Mount Exhaust Curbs up to 20" high must be 18 gauge Aluminized.
5183 Gravity Back Draft Damper 30" X 30" , Standard Galvanized Construction, 1 1/4" Rear Flange, for Size 3 Untempered Fan Housing (5183)
HWCM3 Hot Water Coil Module for Size 3 Modular Fans - 9,530 CFM @ 70deg Temp Rise (720,470 BTU's) Coil = 5MH1202B-30.0x30.5. Opposite airflow requires special order coil with extended lead-time. Temperature controls, mixing valves, thermostats, and freeze protection by others.
Show parts
IHC-MUA3 Indoor Hanging Cradle For The Size 3 Untempered Unit. 2 HSA200 Hanging Isolators per Uni-Strut Included.
Show parts
ADD_STARTER Adds a starter for untempered MPUs.
OPPSIDE-S-CTRLS Mount motor and disconnect on opposite side of fan.
6 Pole Rotary Disconnect 6 Pole 40 Amp Rotary Disconnect for Fans. Includes Switch, switch handle, mounting plate, gasket, and junction box.
Show parts
CVOUTLET GFCI 15 amp Convenience Outlet For Heater Enclosure. Power supply by others - Includes receptacle and J box.
CT-CC DX Cooling Intake Air Thermostat - Ships Loose with Untempered fan - Set Point For Thermostat Should Be 85°F. Do Not Use When Cooling Option is in Pre-Wire Package.
Show parts
EXTENDED-DROP Extended Drop for Commercial Heaters and Supply Fans. Extends the power and remote panel connections to the unit to 20' of total length.
Single Electrical Cabinet LED Lights Single Electrical Cabinet LED Lights Used on Modular MUA Units
Show parts
MB3-MPU Support shell for Size 3 Modular Package Unit. Includes control vestibule. Includes condenser supports. Does not include return air or inlet air damper.
Show parts
MB3-MPU-3-15 Support shell for Size 3 Modular Package Unit for Third Condenser. Includes control vestibule. Includes condenser supports. Does not include return air or inlet air damper.
Show parts
MB3-NC Mixing Box for Size 3 Modular Supply Fan. Actuator and Controls provided by others.
Show parts
MB3-SP Mixing Box for Size 3 Modular Supply Fan. Actuator Control by Static Pressure. Photohelic included.
Show parts
MB3-Manual-0-10V Mixing Box for Size 3 Modular Supply Fan. Actuator Controlled by Manual 0-10V Signal from RTUlink-ACHP board.
Show parts
MB3-MP Mixing Box for Size 3 Modular Supply Fan. Actuator Control by Manual Potentiometer. Manual Potenentiometer included.
Show parts
MB3-TP Mixing Box for Size 3 Modular Supply Fan. 2-Position Actuator Control. Interlock field wired by others. Spring Return to Outside Air Position.
Show parts
MPU3-10-208-1 10 Ton, Dual Circuit (5/5) Modular Packaged Cooling Option for Size 3 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (3,600 to 6,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ0602M
Show parts
MPU3-10-208-3 10 Ton, Dual Circuit (5/5) Modular Packaged Cooling Option for Size 3 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (3,600 to 6,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ0602M
Show parts
MPU3-10-460-3 10 Ton, Dual Circuit (5/5) Modular Packaged Cooling Option for Size 3 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (3,600 to 6,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ0602M
Show parts
MPU3-10-575-3 10 Ton, Dual Circuit (5/5) Modular Packaged Cooling Option for Size 3 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (3,600 to 6,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 575V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ0602M
Show parts
MPU3-10-AC-208-1 10 Ton, Dual Circuit (5/5) Modular Packaged AC Cooling Option for Size 3 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1500 to 4,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1203T
Show parts
MPU3-10-AC-208-3 10 Ton, Dual Circuit (5/5) Modular Packaged AC Cooling Option for Size 3 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1500 to 4000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1203T
Show parts
MPU3-10-AC-460-3 10 Ton, Dual Circuit (5/5) Modular Packaged AC Cooling Option for Size 3 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1500 to 4000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1203T
Show parts
MPU3-10-AC-575-3 10 Ton, Dual Circuit (5/5) Modular Packaged AC Cooling Option for Size 3 Modular Packaged Unit. Includes Condenser, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1500 to 4000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 575V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1203T
Show parts
MPU3-10-AC-HP-208-1 10 Ton, Dual Circuit (5/5) Modular Packaged AC Cooling Option with Heat Pump for Size 3 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1500 to 4,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EY1203T
Show parts
MPU3-10-AC-HP-208-3 10 Ton, Dual Circuit (5/5) Modular Packaged AC Cooling Option with Heat Pump for Size 3 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1500 to 4000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1203T
Show parts
MPU3-10-AC-HP-460-3 10 Ton, Dual Circuit (5/5) Modular Packaged AC Cooling Option with Heat Pump for Size 3 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (1500 to 4000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ1203T
Show parts
MPU3-10-208-1-HP 10 Ton, Dual Circuit (5/5) Modular Packaged Cooling Option with heat pump for Size 3 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Hard Start Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (3,600 to 6,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 1 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ0602M
Show parts
MPU3-10-208-3-HP 10 Ton, Dual Circuit (5/5) Modular Packaged Cooling Option with heat pump for Size 3 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (3,600 to 6,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 208V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ0602M
Show parts
MPU3-10-460-3-HP 10 Ton, Dual Circuit (5/5) Modular Packaged Cooling Option with heat pump for Size 3 Modular Packaged Unit. Includes Heat Pump, DX Coil, Filter/Dryer Kit, Thermal Expansion Valve, R410A Refrigerant, and Refrigerant Piping. (3,600 to 6,000 cfm) When ordered with opposite airflow condensers access and coil piping will remain in standard position. Drain and sleds will move to the opposite side. Any other change will require CLI. CONDENSERS REQUIRE SEPARATE 460V, 3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION. Coil = 3EZ0602M
Show parts
A3UPDISCH-DD Up Discharge Construction for Direct Drive AHUs
Show parts
Shaft Grounding Ring Option Shaft Grounding Ring Option
A3-U-MBDD INS Motorized Back Draft Insulated Damper 30" X 30" for Size 3 Untempered Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, NFBUP-S Actuator Included. Insulated blades and frame. Thermally broken blades.
Show parts
A3-U-MBDD Motorized Back Draft Damper 30" X 30" for Size 3 Untempered Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, NFBUP-S Actuator Included
Show parts
A3-MBDD-SL Motorized Back Draft Discharge Damper Shipped Loose 30" X 30" for Size 3 Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, NFBUP-S Actuator Included, Field Installation Required. Damper, actuator & actuator cover (p/n ACTCOVERMOD) factory assembled.
Show parts
Full Crating for Untempered Fan Full crating for untempered fans for shipping.
SPO18-Enamel Tan Enamel Coating For 18" Fan. Consult factory for other colors. Sherwin Williams p/n F75KXN5809-4347, (AX = A0006229)
Condenser_Locking_Caps_2 Locking caps for double condenser units. Consists of 4 locking caps, part# NCP-4, and 1 key, part# NC-KEY.
Show parts
HP_Condenser_Locking_Caps_2 Locking caps for double heat pump condenser units. Consists of 6 locking caps, part# NCP-4, and 1 key, part# NC-KEY.
Show parts
Condenser_Locking_Caps_3 Locking caps for triple condenser units. Consists of 6 locking caps, part# NCP-4, and 1 key, part# NC-KEY.
Show parts
HP_Condenser_Locking_Caps_3 Locking caps for triple heat pump condenser units. Consists of 9 locking caps, part# NCP-4, and 1 key, part# NC-KEY.
Show parts
DX 3-1 KIT-R410A DX 3-1 Kit R410A. Dual Circuit 10 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
DX 3-2 KIT-R410A DX 3-2 Kit R410A. Dual Circuit 15 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
DX 3-3 KIT-R410A DX 3-3 Kit R410A. Dual Circuit 20 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
DX 3-4 KIT-R410A DX 3-4 Kit R410A. Dual Circuit 25 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
MELIM-3-10-AC MPU3-10-AC Moisture Eliminator Option - allows cooling coil face velocity to increase to 650 fpm. Increases cooling coil max cfm to 4550 cfm.
Show parts
MELIM-3-15-AC MPU3-15-AC Moisture Eliminator Option - allows cooling coil face velocity to increase to 650 fpm. Increases cooling coil max cfm to 5650 cfm.
Show parts
ShipLoose-1C-1PH Ship Condenser Loose - Single Condenser, Single Phase - Condenser Disconnect Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
ShipLoose-1C-3PH Ship Condenser Loose - Single Condenser, Three Phase - Condenser Disconnect Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
ShipLoose-3C-1PH Ship Condensers Loose - Three Condensers, Single Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
ShipLoose-3C-3PH Ship Condensers Loose - Three Condensers, Three Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
ShipLoose-2C-1PH Ship Condensers Loose - Two Condensers, Single Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
ShipLoose-2C-3PH Ship Condensers Loose - Two Condensers, Three Phase - Condenser Disconnects Shipped Loose. All piping and wiring between indoor and outdoor units by others.
Show parts
SP-MPU-2C Single Point MPU Connection, 2 Condensers.
Show parts
SP-MPU-3C Single Point MPU Connection, 3 Condensers.
Show parts
MELIM-3 Size 3 Moisture Eliminator Option for DX Coils, MPUs, and Chilled Water Coils - allows cooling coil face velocity to increase to 650 fpm. Increases cooling coil max cfm to 8150 cfm.
Show parts
MPU3-10-RH Size 3, 10 Ton MPU Reheat Option. Reheat uses warm liquid refrigerant. Reheat runs continuously in stage 1 circuit. Option should not be used if entering air dew point is below 65 degrees F. Nominal Capacity 15.3 MBH. Increases max CFM to 4550.
Show parts
MPU-AC CONTROL Control Package for Mod Package Unit Cooling Only Unit. Includes airflow proving switch, RTUlink-ACHP board and terminal blocks.
Show parts
MPU-HP CONTROL Control Package for Mod Package Unit Heat Pump Unit. Includes airflow proving switch, RTUlink-ACHP board and terminal blocks.
Show parts
D-Hanger Curb Duct Hanger - 1-1/4" Angle Iron Frame Welded to Curb to support standard size ductwork. Priced per curb. Only available when curb assembly is ordered.
MB3-MERV 13-EXTRA Extra set of MERV 13 filters for Size 3 Mixing Box. Uses 4 15 x 20 x 2 inch filters and 2 15 x 15 x 2 inch filters.
Show parts
MB3-MERV 8-EXTRA Extra set of MERV 8 filters for Size 3 Mixing Box. Uses 4 15 x 20 x 2 inch filters and 2 15 x 15 x 2 inch filters.
Show parts
MB3-MERV 13 MERV 13 filter option for Size 3 Mixing Box or Condenser Support. Mixing Box or Condenser Support must be selected for this option. Uses 4 15 x 20 x 2 inch filters and 2 15 x 15 x 2 inch filters.
Show parts
MB3-MERV 8 MERV 8 filter option for Size 3 Mixing Box or Condenser Support. Mixing Box or Condenser Support must be selected for this option. Uses 4 15 x 20 x 2 inch filters and 2 15 x 15 x 2 inch filters.
Show parts
IBS3 Insulated Blower Housing Size 3 Commercial Modular
Ship Modules Separate Ship Modules Separate Option for Modular Units
MB3-TOPRN Top Return Option for Size 3 Mixing Box - No Filter Option Available. Use top return lid and standard DF base.
Show parts
VBI-CSF "Insulation" for V-bank Intake Option.
VB-DS-MB3 V-bank Downstream of Mixing-Box Option Size 3
DCVWP-SUPPLY Separate 120VAC Wiring Package for Make-Up Air Units. Option must be selected when mounting VFD in prewire panel or with DCV package. Provides separate 120VAC input to supply fan. This 120V signal must be run by electrician from DCV to mua switch.
Show parts
VAV-WP-BSPC-UNTEMP VAV (Variable-Air-Volume) Wiring Package for Non Tempered Commercial Fans. Building Static Pressure Variable Frequency Drive Control Included
Show parts
VAV-WP-MC-UNTEMP VAV (Variable-Air-Volume) Wiring Package for Non Tempered Commercial Fans. Manual Speed Control Variable Frequency Drive Included
VAV-WP-PS-UNTEMP VAV (Variable-Air-Volume) Wiring Package for Non Tempered Commercial Fans with Frequency Drive. Preset Speed or Speed Reference Variable Frequency Drive Input Field Wired
VFDINUNIT VFD factory mounted and wired in unit control vestibule.
 
 
 

Security Policy     Privacy Policy     Legal Notice     Warranty     Return Policy
Copyright ® 2003-2014 Thermotek All Rights Reserved.