Sign In         Specifying Software      
 
    Home        About Us        Contact Us        Help Buy Online or Call 1-800-476-5888  
 
 
TTRTU2-E.454-18Z Parts
Motors, Pulleys, & Motor Specific Parts
Motor HP Phs Voltage FLA Shaft Frame Weight RPM Vendor
186726/A01-ECM-50-277-18 1.675 1 208-220-230-240-277 V 9.6-9.1-8.7-8.3-7.2 0.000" 53 lbs 1950 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
186726/A01-ECM-60-277-18 1.675 1 208-220-230-240-277 V 9.6-9.1-8.7-8.3-7.2 0.000" 53 lbs 1950 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
186730/A01-ECM-50-240-18 5.000 3 200-208-230-240 V 10-9.6-8.7-8.3 0.000" 75 lbs 2700 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
186730/A01-ECM-60-240-18 5.000 3 200-208-230-240 V 10-9.6-8.7-8.3 0.000" 75 lbs 2700 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
186731/A01-ECM-50-480-18 5.000 3 460/480 V 5.4/5.2 0.000" 75 lbs 2900 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts
186731/A01-ECM-60-480-18 5.000 3 460/480 V 5.4/5.2 0.000" 75 lbs 2900 Ziehl - Abegg
ODP-ECM (Open Drip Proof Electronically Commutated Motor)  
Show parts

The manufacturer reserves the right to use alternate motors from alternate vendors that meet the operating requirements of the fan but may have slightly different specifications.
Temperature Controls

No Temperature Controls Found.

Blower
Part
18Z-2 18 Inch Plenum Fan for size 2 RTU. Motor integral to Wheel. Max RPM = 3200
Burner
Part
RTUEC-45KW4803 Electric Duct Insert Heater for RTU 480V 3 phase, 45 KW maximum - 1 modulating stage & 1 On/Off Stage, de-energizing contactors, control transformer, disconnect switch, and access door. Coil is 26" wide and 22" long.
 
DP 11-1003
[1 used]
2 Pole Contactor, used with EMC1-20KW2403, EMC1-20KW4803, EMC1-35KW4803, EMC1-50KW4803, EMC2-73KW4803, EMC2-100KW4803, EMC2-73KW6003, EMC3-52KW2403, EMC3-64KW2403, EMC3-175KW6003, EMC4-97KW2403, EMC4-300KW6003, EMC5-151KW2403, EMC5-257KW6003, EMC5-415KW6003, RTUEC-100KW6003, RTUEC-15KW2401, RTUEC-15KW4803, RTUEC-15KW6003, RTUEC-30KW6003, RTUEC-45KW4803, RTUEC-45KW6003, RTUEC-60KW2403, RTUEC-60KW6003, RTUEC-90KW6003, RTUEC1S-15KW2401, RTUEC1S-15KW4803, RTUEC1S-15KW6003, RTUEC1S-30KW6003, RTUEC1S-40KW2403, RTUEC1S-45KW4803, RTUEC1S-45KW6003, RTUEC1S-10KW2403, RTUEC1S-10KW4803, RTUEC1S-10KW6003, RTUEC1L-60KW6003, RTUEC4-90KW4803, RTUEC4-60KW6003, RTUEC4-60KW4803, RTUEC4-45KW4803, RTUEC4-30KW6003, RTUEC5-120KW2403, RTUEC5-150KW2403, and RTUEC5-240KW4803
 
DP 11-1004
[1 used]
3 Pole Contactor, used with EMC1-20KW2403, EMC1-20KW4803, EMC1-35KW4803, EMC1-50KW4803, EMC2-73KW4803, EMC2-100KW4803, EMC2-73KW6003, EMC3-52KW2403, EMC3-64KW2403, EMC3-175KW6003, EMC4-97KW2403, EMC4-300KW6003, EMC5-151KW2403, EMC5-257KW6003, EMC5-415KW6003, RTUEC-15KW4803, RTUEC-15KW6003, RTUEC-30KW6003, RTUEC-45KW4803, RTUEC-45KW6003, RTUEC1S-15KW4803, RTUEC1S-15KW6003, RTUEC1S-30KW6003, RTUEC1S-45KW4803, RTUEC1S-45KW6003, RTUEC1S-10KW2403, RTUEC1L-60KW6003, and RTUEC5-150KW2403
 
DP 24-1002
[1 used]
Automatic Cutout, used with Neptronic electric inserts
 
NW HEC0S02SS
[1 used]
Circuit Board, used with EMC1-50KW4803, EMC1-72KW4803, EMC1-76KW6003, EMC2-45KW2403, EMC2-73KW4803, EMC2-100KW4803, EMC2-73KW6003, EMC2-119KW6003, EMC3-52KW2403, EMC3-64KW2403, EMC3-122KW4803, EMC3-122KW6003, RTUEC-100KW2403, RTUEC-100KW4803, RTUEC-15KW2401, RTUEC-30KW2401, RTUEC-30KW2403, RTUEC-45KW2403, RTUEC-45KW4803, RTUEC-60KW2403, RTUEC-60KW4803, RTUEC-60KW6003, RTUEC-90KW4803, RTUEC-90KW6003, RTUEC1S-15KW2401, RTUEC1S-20KW2401, RTUEC1S-30KW2403, RTUEC1S-40KW2403, RTUEC1S-45KW4803, RTUEC1L-60KW4803, RTUEC1L-60KW6003, RTUEC4-120KW6003, RTUEC4-90KW6003, RTUEC4-90KW4803, RTUEC4-60KW6003, RTUEC4-60KW4803, RTUEC4-45KW4803, RTUEC4-45KW2403, RTUEC4-30KW2403, and RTUEC5-120KW6003
 
DP 13-3005A
[1 used]
Disconnect Switch, used with EMC1-20KW2403, EMC1-35KW4803, EMC1-50KW4803, EMC2-100KW4803, EMC3-143KW4803, EMC5-334KW4803, RTUEC-45KW4803, RTUEC-45KW6003, RTUEC-60KW6003, RTUEC1S-45KW4803, RTUEC1S-45KW6003, and RTUEC1L-60KW6003
 
DP 24-2002
[1 used]
Manual Cutout, used with Neptronic electric inserts
 
DW SSR50Y1
[1 used]
SCR, used with EMC1-20KW2403, EMC1-20KW4803, EMC1-35KW4803, EMC1-50KW4803, EMC1-35KW6003, EMC2-45KW2403, EMC2-73KW4803, EMC2-100KW4803, EMC2-73KW6003, EMC3-122KW4803, EMC3-175KW6003, EMC4-300KW6003, EMC5-257KW4803, EMC5-334KW4803, EMC5-257KW6003, EMC5-415KW6003, RTUEC-100KW6003, RTUEC-15KW2401, RTUEC-15KW2403, RTUEC-30KW2403, RTUEC-30KW4803, RTUEC-30KW6003, RTUEC-45KW4803, RTUEC-45KW6003, RTUEC-60KW4803, RTUEC-60KW6003, RTUEC-90KW4803, RTUEC-90KW6003, RTUEC1S-15KW2401, RTUEC1S-15KW2403, RTUEC1S-30KW2403, RTUEC1S-30KW4803, RTUEC1S-30KW6003, RTUEC1S-45KW4803, RTUEC1S-45KW6003, RTUEC1S-10KW2403, RTUEC1L-60KW2403, RTUEC1L-60KW4803, RTUEC1L-60KW6003, RTUEC4-150KW6003, RTUEC4-120KW4803, RTUEC4-60KW6003, RTUEC4-60KW2403, RTUEC4-45KW4803, RTUEC4-45KW2403, RTUEC4-30KW6003, RTUEC4-30KW4803, RTUEC4-30KW2403, RTUEC5-120KW4803, RTUEC5-120KW6003, RTUEC5-150KW4803, RTUEC5-150KW6003, RTUEC5-180KW4803, RTUEC5-180KW6003, RTUEC5-210KW6003, and RTUEC5-240KW6003
 
DP 10-8003
[1 used]
Step Down Transformer 480 VAC to 24 VAC, used with EMC1-35KW4803, EMC1-50KW4803, EMC1-72KW4803, EMC2-73KW4803, RTUEC-100KW4803, RTUEC-45KW4803, RTUEC-60KW4803, RTUEC-90KW4803, RTUEC1S-45KW4803, RTUEC1L-60KW4803, RTUEC4-90KW4803, RTUEC4-60KW4803, and RTUEC4-45KW4803
Replacement Parts
Part
33008
[8 used]
A0003208 - 3/8" WASHERS
95475A640
[1 used]
Zinc-Plated Steel Fully Threaded Stud, 3/8"-16 Thread, 4" Length
SU201M-K10
[1 used]
CIRCUIT BREAKER - 10 AMP Circuit Breaker Used for Indirect Heaters. Trip Curve D. UL489. Old P/N S201U-K10
Controller&HMI
HMI_STANDOFF
[-1 used]
18 AWG 430 SS HMI standoff. Used with HMI that has populated RH and barometric pressure sensors.
HMI_01_MUA
[1 used]
HMI assembly. Preprogrammed for use with MUA Board. Includes CASHMI PCB, 4 mounting screws, 16 ga. SS backing plate, membrane switches & gasket.
Direct Fired Air Movement Control Components
8164
[5 used]
1/4" Nylon Tubing - Used with the Modular Make-Up Air Units A1-D, A2-D, A3-D, A4-D, A5-D and the NHMUA1, NHMUA2, NHMUA3, AI (Price Per Foot). Type 12.
17045
[2 used]
Airflow Switch Components Cleveland Controls Airflow Probe 2".
Evaporative Cooler Control
FS3201-122
[1 used]
Liquid level sensor - Float switch for MPUs and RTU. Hardware Specifications: 1/8" NPT. 20ft wire leads.
Evaporative Cooler Sheet Metal Parts
ME15SMFLAT
[1 used]
MPU Float sensor mounting bracket GALV20GA
Exhaust Fan Parts
94831A001
[8 used]
CASRE Switch Enclosure Mounting Hardware - Zinc-Plated Steel Serrated-Flange Hex Locknut 6-32 Thread Size, 5/16" W, 11/64" Height.
0125617
[6 used]
Rivsert - 1/4" - 20 Rivet Insert Used On USBI - 95105A143 - Product Detail Zinc-Plated Steel Heavy-Duty Rivet Nut, Open End, 1/4"-20 Interior Thread,.027"-.165" Material Thickness
Exhaust Fan Whiz Nuts & Bolts
0120763.0800
[28 used]
A0031100 - 1"L, 1/4-20 Matpoint, Self Aligning, Hex Head, Grade 5 Bolt
11626-03224
[53 used]
Cage Nut - 1/4" - 20. Installed in 1/2" square hole. Used on 20 gauge material.
Intakes & Accessories
DUCTBOARD
[1 used]
DUCTBOARD 4X10 SHEET Owens Corning Type 475FRK Insulation. 1 Sheet.
Miscellaneous Electrical Parts
KEL-BES 10
[5 used]
Cable Pass-Through with Brush Frame (Icotek#51505)
CAT5_Regular_1
[4 used]
CAT-5E Cable - 1.0 Foot. FAN PART
34.101.1766.0
[1 used]
DOAS Terminal Block Assembly
8098
[30 used]
Heyco Bushing SB-875-11, .685 Dia. Ins. X .850 Dia. Out. X .450 Height, Matl. Plastic Black
58371-1/2
[1 used]
Junction Box - 2 1/8" X 4" X 2 1/16" - Used for mounting Speed Controls and 3 pole switches. 2-1/8" Deep.
MUA Board
[1 used]
Printed Circuit board for use in heaters. Used in conjunction with CAS HMI.
BZ-2RQ1-A2
[3 used]
Switch, overtravel switch for door sense, single pole, double throw. Screw terminals
Miscellaneous Heater Components
1128804
[4 used]
#6-32 x 1/2" Phillips Pan Head Zinc Plated Machine Screw (A0001009)
NBB4000516
[4 used]
5/16" NUTS
WA4000516
[24 used]
5/16" WASHERS
3M467J
[1 used]
Captiveaire Factory Direct sticker
HG-OTA100
[11 used]
Removable Door Hinge used on Pollution Control Units and KB Blowers
Miscellaneous Hood Parts
104778
[3 used]
SEALANT - 10.3 oz Silicone Silver/Aluminum Sealant. 350 deg silicone used in hoods. (item #104778)
Motorized Dampers
RTUSER100AA82RD
[1 used]
Size 2 Integrated OA/RA Damper Assembly
Pollution Control Gasket
4790-92 1/2" BY 1"-FT
[6 used]
PORON polyurethane - EXTRA SOFT - 4790-92, -1/2" by 1" , Black in Color. Backing is 3 M™ Adhesive 350 acrylic ideal for very high-bond strength to many surfaces. Price by foot.
Pollution Control Hardware
SSB64S-RIVET
[88 used]
Rivet. 3/16" Stainless Steel rivet for PCU. 3/16" Dia. Grip Range:0.126" - 0.250", SSB64S Blind Rivet.
Product Manuals
MANUAL RTU
[1 used]
Manual for Packaged Rooftop Unit
Refrigeration Parts
2LKJ3-INCH-MPU/RTU
[4 used]
1/2 In ACR Copper Tubing. 1 in Length. Inside Diameter = .430, Outside Diameter = .500. Max Pressure = 727 PSI, 400 F Max. ASTMB280
4217-12 per inch
[12 used]
Cork-Tite Insulation Tape per inch
RTU Electrical Components
02-23350-00
[1 used]
Description: 120V 65W crankcase and accumulator band heater. 6” to 8 3/8” Dia. Used on VZH028 to 065 compressors and all accumulators except for the RTU3642
RTU Miscellaneous Components
92323A529
[2 used]
1/4"-20 x 3" Flange Bolt. Price for 1 bolt. (package of 25)
6920K24
[1 used]
Aluminum Set Screw Ground Lug 14 to 2/0 AWG 1/4" Stud
A7-10-351-20
[6 used]
Black Compression Handle Latch and Clasp
MGPL-R6-4
[300 used]
Huck Interlock Rivet - 3/16" Diameter - Grip Range Min = .062" / Max = .270". RIVET Fastening System.
LED Strip
[1 used]
LED Strip Light 3 feet 24V DC.
91735A146
[2 used]
Type 316 Stainless Steel Pan Head Phillips Machine Screw, 6-32 Thread, 3/8" Length.
RTU Sheet Metal Components
RTU2BAVS
[4 used]
RTU 2 Blower Assembly Vertical Support. 14ga Sheet Metal Part
RTU2CS
[1 used]
RTU 2 Compressor Support. 14ga Sheet Metal Part
RTU2CSCSBT
[1 used]
RTU 2 Condenser Separator - Condenser Side Bottom. 20ga Sheet Metal Part
RTU2CSCS
[1 used]
RTU 2 Condenser Separator - Condenser Side. 20ga Sheet Metal Part
RTU2EBA
[1 used]
RTU 2 Economizer Bottom Angle. 20ga Sheet Metal Part
RTUHFP
[4 used]
RTU Hole Fill Plate. Shared 20ga Sheet Metal Part
RTUMSH
[1 used]
RTU Manual and Schematic Holder. Shared 20ga Sheet Metal Part
RTUMASB
[2 used]
RTU Mixed Air Sensor Bracket. Shared 14ga Sheet Metal Part
Supply Fan Filters
9151
[2 used]
MV EZ Kleen Metal Mesh Filter. 20"x 25"x 2" Used for heater and supply fan intakes. (3416)
Supply Fan Vibration Isolators
L1VIB
[4 used]
Motor Frame Vibration Eliminator 1" Out. Dia. X 1/4" Tall, Rubber (Black) New Style, 5/16-18 x 1/2 dual studs. Durometer = 50
Thermostats/Sensors
A/CP-DO-240-QC
[3 used]
10K, Type II thermistor with 6" probe. 20' wire leads. (Replaces part# A/CP-DO-120-QC)
CP-HT-FA-12
[2 used]
High Temp 10K, Type II thermistor with average sensor wire 12' long operable up to 200F. No metal box included.
Transformers
BE161640GEK0018
[1 used]
TRANSFORMER - Low 40VA Voltage Transformer Used for 120v Primary and 24v Secondary.
Curbs
Part
CRB49.50X75X30INS ROOF CURB - 49.5" Width, 75" Length, 30" Supply Height, Insulated.
CRB49.50X75X32INS ROOF CURB - 49.5" Width, 75" Length, 32" Supply Height, Insulated.
Options
Part
120V Fire Input 120V Fire Input
24VAC Fire Input 24VAC Fire Input
CSMDTIL Commercial Smoke Detector Interlock (Detector By Others)
D4120-DST-1.5-C Duct Mounted Smoke Detector For Commercial Direct Fired Heater. Complete with detector (D4120) and sampling tube (DST-1.5). Ships Loose
Show parts
CABHTR100WNC Control panel enclosure heater, includes 100w, 120v heater. Recommended for winter design temperature less than 0°F. Operates on PCB controls in IBT Single Modules or RTU
Show parts
RTU2-10TCOND-ECOAT Ecoating for Size 2 RTU 10T Condenser Coil.
Show parts
RTU2-10TEVAP-ECOAT Ecoating for Size 2 RTU 10T Evap Coil.
Show parts
RTU2-8TCOND-ECOAT Ecoating for Size 2 RTU 8T Condenser Coil.
Show parts
RTU2-8TEVAP-ECOAT Ecoating for Size 2 RTU 8T Evap Coil.
Show parts
FUSED_DOAS_2 FUSED DISCONNECT SWITCH FOR SIZE 2 DOAS
Show parts
ECM 0-10V Control - RTU/MUA ECM 0-10V Supply Fan Control
ECM 0-10V Control - RTU MUA Board ECM 0-10V Supply Fan Control - RTU MUA Board
ECM Building SP Control - RTU MUA Board ECM Building SP Control RTU MUA Board
Show parts
ECM Duct SP Control - RTU MUA Board ECM Duct Static Pressure Control
Show parts
ECM Control - RTU MUA Board (Ziehl Motor) ECM Wiring Package - Supply Fan Control RTU MUA Board
ECM Control - RTU/MUA (Ziehl Motor) ECM Wiring Package - Supply Fan Control-(3 Phase Ziehl Motor)
ECM Wiring Package-ECPM03 RTU ECM Wiring Package-RTU/MUA - PWM Signal from ECPMO3 Prewire
MIAMI-DADE CERT RTU SIZE 2 Miami Dade Impact and Wind Load Certification - Miami Dade County Product Control Approved. Florida Building Code approval. Curbs up to 20" high must be 18 gauge Aluminized.
Separate Electric Heat Connection - RTU Separate Electric Heat Connection - RTU. QNTY 1 750va Transformer Used for controls. Two primary connections required for RTU with electric heat. If a Non-DCV Prewire controls this unit, the #28, #47, "MA", or "E2" Option Prewire must be selected. Do not provide supply starter in prewire.
Single Point Electric Heat - RTU Single Point Electric Heat Connection - RTU. QNTY 1 750va Transformer used for controls. One primary connection required for RTU with electric heat. If a Non-DCV Prewire controls this unit, the #28, #47, "MA", or "E2" Option Prewire must be selected. Do not provide supply starter in prewire.
Show parts
IBT ROOM OVERRIDE Option Control for IBT/RTU Scheduling. Do not order as a part.
Auxiliary Reheat Auxiliary Reheat - Uses back up heat (Electric) as secondary reheat.
Blower Delay Start Blower Delay Start. Allows Indirect Furnace to pre-heat before blower operation. Factory set at 90 seconds. TI-11 set at 20 seconds. TI-12 set at 90 seconds.
Burner-Interlock-IBT/RTU Burner Interlock Input. Locks out cooling when interlock is energized.
CLCOMM_REV04 CASLink building monitoring system communications module. Requires internet & field wired ethernet connection or 3G cellular service. Includes Rev 3 Comm Module, RJ45 to modbus converter, 3 FT cat5 cable, and 1 FT of shielded twisted pair.
Show parts
Construction Mode Unit will be shipped with construction mode ON. This is used to provide tempering for a building in construction. Activation is set to Intake, Tempering is set to Discharge, Mixing Box is set to 100% OA and HMI number is 1.
AC-Interlock-IBT/RTU Cooling Interlock Input to PCB Board. Locks out burner circuit when AC is energized.
Dry Mode Exhaust Current Sensor Mounted In Exhaust Fan For Use With Pool Room Temp Control
Show parts
SAMSUNG-MODBUS AUXILIARY MODBUS CONNECTION FOR USE WITH SAMSUNG CONTROLLER
DDC-IP BACnet Monitoring Remote IP BACnet monitoring for supply fans.
Show parts
DDC-LONWorks Monitoring Remote LONWorks monitoring for supply fans.
Show parts
DDC-MSTP BACnet Monitoring Remote MSTP BACnet monitoring
Show parts
Dry Mode Dry Mode
Show parts
ECM Fan DOAS - 1 Phase ECM Fan DOAS - 1 Phase
ECM Fan DOAS - 3 Phase ECM Fan DOAS - 3 Phase
FECONTAAFS Field Wired Exhaust Contactor After Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP 230v, 15HP max. 460V, 15HP max. 575V or (4) Dry Interlocks. Overload not Included
Show parts
FECONTBAFS Field Wired Exhaust Contactor Before Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP max 230v, 15HP max. 460V. Overload not Included
Show parts
Exhaust on Fire Exhaust on Fire
Extreme Low Ambient Cooling Low ambient cooling controls down to -20F ambient temperatures. To be used in recirculating applications.
Show parts
Low Ambient Cooling Low ambient cooling controls down to 0F ambient temperatures. To be used in recirculating applications.
OCCUPIED SCHEDULING Occupied Scheduling Defaulted for IBT/RTU.
Supplemental Back Up Heat Heat Pump continues to operate along with back up electric heat.
Supply Duct Adjustment Unit will discharge above space dewpoint to avoid condensation outside of duct. To be used in space control with CAS supply duct.
Supply Fan Preset Speed Supply Fan Preset Speed Input to PCB. Field Wired.
CLOGFILTHMI Clogged Filter Switch with Notification on HMI
Show parts
Purge mode Purge option selected. Allows the user to purge the space by manually activtating on the HMI.
Show parts
CVOUTLETRTU2 GFCI 15 amp Convenience Outlet For RTU2 Enclosure. 120V power supply by others. Includes receptacle, jbox & cover.
Show parts
PCVOUTLETRTU2 GFCI 15 amp Powered Convenience Outlet For RTU2 Enclosure. Includes receptacle, jbox, cover and transformer.
Show parts
Shaft Grounding Ring Option Shaft Grounding Ring Option
ENAM-RTU2 Tan Enamel Coating (exterior walls/roof) For RTU 2. Consult factory for other colors. Sherwin Williams p/n F75KXN5809-4347, (AX = A0006229)
RTU-10T-AC-208/230 10 Ton Modulating Cooling Option, 208/230V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-10T-AC-460/480 10 Ton Modulating Cooling Option, 460/480V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-10T-AC-575/600 10 Ton Modulating Cooling Option, 575/600V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-AC-208/230 - 1 PHASE 8 Ton Modulating Cooling Option, 208/230V - 1 Phase. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-AC-208/230 8 Ton Modulating Cooling Option, 208/230V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-AC-460/480 8 Ton Modulating Cooling Option, 460/480V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-AC-575/600 8 Ton Modulating Cooling Option, 575/600V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-10T-AC-208/230-HA High Ambient - 10 Ton Modulating Cooling Option, 208/230V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-10T-AC-460/480-HA High Ambient - 10 Ton Modulating Cooling Option, 460/480V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-AC-208/230-HA High Ambient - 8 Ton Modulating Cooling Option, 208/230V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-AC-460/480-HA High Ambient - 8 Ton Modulating Cooling Option, 460/480V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-10T-HP-208/230 10 Ton Modulating Cooling Option with Heat Pump, 208/230V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-10T-HP-460/480 10 Ton Modulating Cooling Option with Heat Pump, 460/480V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-10T-HP-575/600 10 Ton Modulating Cooling Option with Heat Pump, 575/600V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-HP-208/230 - 1 PHASE 8 Ton Modulating Cooling Option with Heat Pump, 208/230V - 1 Phase. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-HP-208/230 8 Ton Modulating Cooling Option with Heat Pump, 208/230V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-HP-460/480 8 Ton Modulating Cooling Option with Heat Pump, 460/480V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-HP-575/600 8 Ton Modulating Cooling Option with Heat Pump, 575/600V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-10T-HP-208/230-LA Low Ambient - 10 Ton Modulating Cooling Option with Heat Pump, 208/230V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-10T-HP-460/480-LA Low Ambient - 10 Ton Modulating Cooling Option with Heat Pump, 460/480V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-HP-208/230-LA Low Ambient - 8 Ton Modulating Cooling Option with Heat Pump, 208/230V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-HP-460/480-LA Low Ambient - 8 Ton Modulating Cooling Option with Heat Pump, 460/480V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-10T-HP-208/230-HA High Ambient - 10 Ton Modulating Cooling Option with Heat Pump, 208/230V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-10T-HP-460/480-HA High Ambient - 10 Ton Modulating Cooling Option with Heat Pump, 460/480V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-HP-208/230-HA High Ambient - 8 Ton Modulating Cooling Option with Heat Pump, 208/230V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-8T-HP-460/480-HA High Ambient - 8 Ton Modulating Cooling Option with Heat Pump, 460/480V. R410A Refrigerant, Variable Speed Inverter Duty Compressor, ECM Condensing Fan(s).
Show parts
RTU-10TCO-REHEAT DISCHARGE 10 Ton Cooling Only Modulating Reheat Option for Discharge Control
Show parts
RTU-10TCO-REHEAT SPACE 10 Ton Cooling Only Modulating Reheat Option for Space Control
Show parts
RTU-10THP-REHEAT DISCHARGE 10 Ton Heat Pump Modulating Reheat Option for Discharge Control
Show parts
RTU-10THP-REHEAT SPACE 10 Ton Heat Pump Modulating Reheat Option for Space Control
Show parts
RTU-8TCO-REHEAT DISCHARGE 8 Ton Cooling Only Modulating Reheat Option for Discharge Control
Show parts
RTU-8TCO-REHEAT SPACE 8 Ton Cooling Only Modulating Reheat Option for Space Control
Show parts
RTU-8THP-REHEAT DISCHARGE 8 Ton Heat Pump Modulating Reheat Option for Discharge Control
Show parts
RTU-8THP-REHEAT SPACE 8 Ton Heat Pump Modulating Reheat Option for Space Control
Show parts
ELEC Only Reheat ELEC Only Reheat - Uses back up heat (Electric) as reheat.
Show parts
RTU-10T ME NO REHEAT 10 Ton Size 2 RTU Moisture Eliminator - No reheat. Single row moisture eliminator aluminum coil.
Show parts
RTU-8T ME NO REHEAT 8 Ton Size 2 RTU Moisture Eliminator - No reheat. Single row moisture eliminator aluminum coil.
Show parts
No Reheat No Reheat Option
Show parts
RTU Size 2 DD Electric Heat RTU Size 2 Down Discharge Electric Heat
Show parts
RTU Size 2 SD Electric Heat RTU Size 2 Side Discharge Electric Heat
Show parts
RTU Econ Differential Dry Bulb Differential dry bulb controls that modulate OA percentage based off return air temperature and a temperature set point.
RTU Econ Differential Enthalpy Differential enthalpy controls that modulate OA percentage based off return air temperature and relative humidity.
Show parts
RTU Econ Fixed Dry Bulb Fixed dry bulb controls that modulate OA percentage based off temperature set points.
RTU Econ Fixed Enthalpy Fixed enthalpy controls that modulate OA percentage based off temperature and relative humidity set points.
Show parts
RTU 2 Economizer Relief Barometric Relief for RTU Size 2 Economizer
Show parts
DP13-STD2-203 - ERV 2 2" Merv 13 Filters for Size 2 ERV. QTY 2, 20 x 20 x 2 Merv 13 Filters
Show parts
DP13-STD2-201-4 2" Merv 13 Filters for Size 2 RTU. QTY 4, 16 x 20 x 2 Merv 13 Filters
Show parts
TA 16X20X2 - 4 2" Merv 8 Filters for Size 2 RTU. QTY 4, 16 x 20 x 2 Merv 8 Filters
Show parts
9154 - 4 2" Metal Mesh Filters for Size 2 RTU. QTY 4, 16 x 20 x 2
Show parts
Damper Presets Damper Preset Position Input to PCB. Field Wired.
Show parts
RTU 2 Fixed 100% RA Intake Control RTU 2 Fixed 100% Return Air Intake.
Show parts
RTU BAS Intake Control RTU BAS Intake Control. Actuator Control by 2-10VDC Input by Others.
Show parts
RTU Fixed 100% OA Intake Control RTU Fixed 100% Outdoor Air Intake.
Show parts
RTU Static P Intake Control MUA Board RTU Static Pressure Intake Control. Uses ACI pressure transducer.
Show parts
RTU Static P Intake Control RTU Static Pressure Intake Control. Intake Position Controlled by Photohelic Static Pressure Output. Photohelic Included
Show parts
RTU Manual 0-10V Intake Control RTU Manual 0-10V Intake Control. Actuator Control by 0-10VDC Output on Control Board. Intake Position Controlled Manually via HMI.
Show parts
RTU OA Percentage Intake Control RTU Outdoor Air Percentage Intake Control. Actuator Control by 0-10VDC Output on Control Board to Maintain Desired Outdoor Air %.
Show parts
RTU Field Wired Intake Switch Control RTU Field Wired Intake Switch Control. Actuator Control by Field Wired Switch into Control Board.
Show parts
RTU Analog 0-10V Intake Control RTU Analog 0-10V Intake Control. Actuator and intake position controlled by a 0-10VDC analog input to IBT board by others.
Show parts
RTU Compressor Oil Sensor-M12 RTU Compressor Oil Sensor Factory Installed. M12 Style Connector.
Show parts
RTU 2 Hail Guard RTU Size 2 Hail Guard for outdoor coil. Includes magnets and washers for installation.
Show parts
RTU Return as Space with Reheat RTU Return as Space with Reheat
Show parts
RTU Size 2 Down Return RTU Size 2 Down Return
Show parts
RTU Size 2 Down Return - 100% RA RTU Size 2 Down Return - 100% RA
Show parts
RTU Size 2 No Return RTU Size 2 No Return
RTU Size 2 No Return - Heat Only RTU Size 2 No Return - Heat Only
RTU Size 2 No Return - MPU RTU Size 2 No Return - MPU
RTU Size 2 Side Return RTU Size 2 Side Return
Show parts
RTU Size 2 Side Return - 100% RA RTU Size 2 Side Return - 100% RA
Show parts
RTU2-VBANK-HEPA 4" HEPA Vbank Module for Size 2 RTU. QTY 8 16 x 20 x 4 Filters Right to Left Airflow Configuration.
Show parts
RTU2-VBANK-HE 4" MERV 15 Vbank Module for Size 2 RTU. QTY 8 16 x 20 x 4 HE Filters Right to Left Airflow Configuration.
Show parts
RTU2 D-Hanger Size 2 RTU Curb Duct Hanger - Adjustable Duct Hanger Support Brackets installed for both return and discharge duct.
FIRESTAT-DISCHARGE- Discharge Firestat. Set to 240°F
FREEZESTAT- Freezestat factory set at 35°F and 10 minutes.
FIRESTAT-INTAKE- Intake Firestat. Set to 135°F
Overheat Stat Overheat Stat factory set at 80°F and 10 minutes. Prevents unit from overheating the space when cooling.
IBT/RTU remote Space Sensor Temp/Hum Remote Room Sensor Option. Wall Mountable 10k Temp and Humidity Room Sensor Included.
Show parts
CFM Monitoring - RTU CFM monitoring for MUA units. Uses rivet nuts, 1/4" airflow tubing and push to connect fittings.
Show parts
Blower Delay Stop Blower Delay Stop. Allows supply fan to run after the burner has shut off Factory set at 90 secs for indirect 30 secs for direct.
VAV-WP-VDC-INPUT-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. 0-10VDC Speed Control Variable Frequency Drive Included
VAV-WP-BSPC-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Building Static Pressure Variable Frequency Drive Control Included
Show parts
VAV-WP-BSPC-PCBMUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Building Static Pressure Variable Frequency Drive Control Included-MUA Board
Show parts
VAV-WP-DSPC-PCBMUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Duct Static Pressure Variable Frequency Drive Control Included- MUA Board
Show parts
VAV-WP-MC-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Manual Speed Control Variable Frequency Drive Included
SLFB750-4 Floor Mount Vibration Isolators. Option for the size 2 RTU. Max Weight = 750 lbs. 1.12" Deflection. 1/2" Bolt Diameter. Set of 4. White Spring.
Show parts
 
 
 

Security Policy     Privacy Policy     Legal Notice     Warranty     Return Policy