T5-IBT-1200-400-400-400-925 Parts
Motors, Pulleys, & Motor Specific Parts
Motor HP Phs Voltage FLA Shaft Frame Weight RPM Vendor
00318OS1C184T 3.000 1 208-230 V 18.6-17.5 1.125" 184T 73 lbs 1745 WEG
ODP (Open Drip Proof) Pulleys
Show parts
00518OS1C184T 5.000 1 208-230 V 27.1-24.6 1.125" 184T 99 lbs 1750 WEG
ODP (Open Drip Proof) Pulleys
Show parts
00318OT3E56Z-48PP 3.000 3 208-230/380/460 V 8.7-7.9/4.8/3.9 0.875" 56 55 lbs 1730 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
00318OT3H182T-S 3.000 3 575 V 3 1.125" 182T 66 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
00518OT3H184T-S 5.000 3 575 V 5 1.125" 184T 80 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0054 5.000 3 190/200-208-230/380/400/415/460 V 17/15.6-15-13.6/8.5/7.7/7.5/6.8 1.125" 184T 77 lbs 1750 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
00718OT3H213T-S 7.500 3 575 V 7.4 1.375" 213T 116 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP7/54 7.500 3 200-208-230/380/400/460 V 21.5-21.1-19.1/11.4/10.8/9.6 1.375" 213T 104 lbs 1750 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0104 10.000 3 190/208-230/380/460 V 29.9/27-24.4/15/12.2 1.375" 215T 143 lbs 1755 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
01018OT3H215T-S 10.000 3 575 V 9.9 1.375" 215T 137 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0104-50 10.000 3 190/380/415 V 30/15/13.7 1.375" 215T 143 lbs 1436 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0154 15.000 3 208-230/380/460 V 40.3-36.4/22.7/18.2 1.625" 254T 231 lbs 1755 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
01518OT3H254T-S 15.000 3 575 V 14.9 1.625" 254T 175 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
02018OT3H256T-S 20.000 3 575 V 20 1.625" 256T 198 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0204 20.000 3 208-230/460 V 53.7-48.6/24.3 1.625" 256T 269 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
GP7/54 7.500 3 190/200-208-230/380/400/460 V 22.4/21.4-20.5-18.5/11.2/10.7/9.3 1.375" 213T 148 lbs 1800 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
GP0104 10.000 3 190/200-208-230/380/400/460 V 29.6/27.8-26.6-24/14.8/13.9/12 1.375" 215T 159 lbs 1755 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0154 15.000 3 190/208-230/380/460 V 41.8/38.2-34.5/20.9/17.3 1.625" 254T 250 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0204 20.000 3 190/208-230/380/460 V 55.7/50.8-46/27.8/23 1.625" 256T 287 lbs 1760 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts

The manufacturer reserves the right to use alternate motors from alternate vendors that meet the operating requirements of the fan but may have slightly different specifications.
Intakes & Intake Parts
Part
CD-VB-I-05M-TA Celdek and V-Bank for Size # 5 Modular Make Up Air unit with TA Filters. For indoor installation. MERV 8 V-Bank Filters.
Show parts
CD-VB-O-05M-TA Celdek and V-Bank for Size # 5 Modular Make Up Air unit with TA Filters. For outdoor installation. MERV 8 V-Bank Filters. Includes Screened Intake
Show parts
CD-VB-I-05M-TA-13 Celdek and V-Bank for Size # 5 Modular Make Up Air unit with TA Filters. For indoor installation. MERV 13 V-Bank Filters.
Show parts
CD-VB-O-05M-TA-13 Celdek and V-Bank for Size # 5 Modular Make Up Air unit with TA Filters. For outdoor installation. MERV 13 V-Bank Filters. Includes Screened Intake
Show parts
CD-VB-I-05M Celdek and V-Bank for Size # 5 Modular Make Up Air unit. For indoor installation.
Show parts
CD-VB-O-05M Celdek and V-Bank for Size # 5 Modular Make Up Air unit. For outdoor installation. Includes Screened Intake
Show parts
CD-O A5-IH Celdek Evaporative Cooler for Size # 5 Modular Make Up Air unit. 59.563" Wide x 105.238" Long x 58.375" High. Includes intake hood with filters. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A5-NF Celdek Evaporative Cooler for Size # 5 Modular Make Up Air unit. 59.563" Wide x 105.238" Long x 58.375" High. Includes intake hood without filters. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A5 Celdek Evaporative Cooler for Size # 5 Modular Make Up Air unit. 59.563" Wide x 85" Long x 58.375" High. Includes screened intake. For outdoor installation. Use with water softener recommended.
Show parts
CD-I A5 Celdek Evaporative Cooler for Size # 5 Modular Make Up Air unit. 59.563" Wide x 35.188" Long x 58.375" High. For indoor installation. Min. water pressure for optimal performance is 30 PSI. Max. water pressure should not exceed 50 PSI. Use with water softener recommended.
Show parts
SI-5 Screen Intake for Size 5 Commercial Fans.
Show parts
CD-O A6-5 Size # 6 Celdek Evaporative Cooler for Size # 5 Modular Make Up Air unit. 74.822" Wide x 85" Long x 58.375" High. Includes screened intake. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A6-IH-5 Size # 6 Celdek Evaporative Cooler for Size # 5 Modular Make Up Air unit. 74.822" Wide x 105.238" Long x 58.375" High. Includes intake hood with filters. For outdoor installation. Use with water softener recommended.
Show parts
CD-O A6-NF-5 Size # 6 Celdek Evaporative Cooler for Size # 5 Modular Make Up Air unit. 74.822" Wide x 105.238" Long x 58.375" High. Includes intake hood without filters. For outdoor installation. Use with water softener recommended.
Show parts
CD-I A6-5 Size # 6 Celdek Evaporative Cooler for Size # 5 Modular Make Up Air unit. 74.822" Wide x 35.188" Long x 58.375" High. For indoor installation. Min. water pressure for optimal performance is 30 PSI. Max. water pressure should not exceed 50 PSI. Use with water softener recommended.
Show parts
CD-LPD-VB-I-06-5M-TA-13 Size # 6 LPD Celdek and V-Bank for Size # 5 Modular Make Up Air unit. For indoor installation.
Show parts
CD-LPD-VB-I-06-5M Size # 6 LPD Celdek and V-Bank for Size # 5 Modular Make Up Air unit. For indoor installation.
Show parts
CD-LPD-VB-I-06-5M-TA Size # 6 LPD Celdek and V-Bank for Size # 5 Modular Make Up Air unit. For indoor installation.
Show parts
CD-LPD-VB-O-06-5M-TA Size # 6 LPD Celdek and V-Bank for Size # 5 Modular Make Up Air unit. For outdoor installation. Includes Screened Intake
Show parts
CD-LPD-VB-O-06-5M Size # 6 LPD Celdek and V-Bank for Size # 5 Modular Make Up Air unit. For outdoor installation. Includes Screened Intake
Show parts
CD-LPD-VB-O-06-5M-TA-13 Size # 6 LPD Celdek and V-Bank for Size # 5 Modular Make Up Air unit. For outdoor installation. Includes Screened Intake
Show parts
SFIH-05M Sloped Filtered Intake for Size #5 Modular Make Up Air unit. 55.81" Wide X 70.05" Long X 51.00" High. Includes 2" MV EZ Kleen Metal Mesh FIlter.
Show parts
VB-O-05M-TA V-Bank for Size # 5 Modular Make Up Air unit with TA Filters. Includes screened intake. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
VB-I-05M-TA V-Bank for Size # 5 Modular Make Up Air unit with TA Filters. For indoor installation. MERV 8 V-Bank Filters.
Show parts
VB-I-05M-TA-13 V-Bank for Size # 5 Modular Make Up Air unit with TA Filters. For indoor installation. MERV 13 V-Bank Filters.
Show parts
VB-O-05M-TA-13 V-Bank for Size # 5 Modular Make Up Air unit with TA Filters. Includes screened intake. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
VB-I-05M V-Bank for Size # 5 Modular Make Up Air unit. EZ Metal Mesh Filters. For indoor installation.
Show parts
VB-O-05M V-Bank for Size # 5 Modular Make Up Air unit. EZ Metal Mesh Filters. Includes screened intake. For outdoor installation.
Show parts
VB-O-05M-TA-13-IH-EZ V-Bank for Size #5 Modular Indirect-Fired Heater with TA Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 13 V-Bank Filters.
Show parts
VB-O-05M-TA-IH-EZ V-Bank for Size #5 Modular Make-Up Air unit with TA Filters. Includes intake hood with EZ filters. For outdoor installation. MERV 8 V-Bank Filters.
Show parts
Temperature Controls

No Temperature Controls Found.

Gas Manifold Parts

No Gas Manifold Parts Found.

Blower
Part
925 25" forward curved, centrifugal blower. Permanently lubricated pillow block ball bearings. Enamel finish. 10000-25000 CFM. 2 3/16" x 54-1/2" Shaft. 1000 maximum RPM. Heavy duty angle iron frame. Used in heated and non-heated supply fans.
Burner
Part
IBT1200-400-400-400 Bent Tube Furnaces - 1,200,000 BTU/HR maximum input, 960,000 BTU/HR maximum output, 53,333 BTU/HR minimum output for NG, 64,000 BTU/HR minimum output for LP. Includes (3) 400 MBH Input Furnaces. Stainless Steel Burner, Heat Exchanger, and Power Vent. No contols or sheet metal housing. Used in size 3,4, and 5 IBT.
 
CP715IBT
[3 used]
FURNACE - 400,000 BTU/HR Indirect Fired Bent Tube Furnace with Stainless Steel Heat Exchanger, Burner, and Power Vent. No contols or sheet metal housing. Indoor use only. Used in IBT.
Replacement Parts
Part
33008
[72 used]
A0003208 - 3/8" WASHERS
8003
[3 used]
CONDUIT CONNECTOR - 90deg; 1/2" Bridgeport, 1/2" long thread
5RS
[3 used]
5" MV Storm Collar
5BVVTH
[3 used]
5'' DuraVent Type B High-Wind Cap. High Wind B Vent cap meets the UL standard for "high Wind" which is a 45 MPH test. Direct replacement for part number 5RHW and 5GVVTH.
5RP12
[3 used]
B-Vent, 5 inch diameter, 12 inches long. Used in IBT.
5RP18
[6 used]
B-Vent, 5 inch diameter, 18 inches long. Used in IBT.
90416
[3 used]
High Temp Silicone Rubber Tubing for IBT power vent. Durometer=50, .25" OD, .125" ID, 450°F Max continuous temperature. Sold Per foot.
P5BT445
[3 used]
Square to Round Adapter Used on IBT Heaters. Adapts Power Vent to 5" Round B-Vent. Large Adapter.
Common Heater Components
HMI_Bracket
[1 used]
20 GA. Galvanized. Used on IBT controls
Common Heater Electrical Components
SU201M-K10
[1 used]
CIRCUIT BREAKER - 10 AMP Circuit Breaker Used for Indirect Heaters. Trip Curve D. UL489. Old P/N S201U-K10
Controller&HMI
HMI_01_IBT
[1 used]
HMI assembly. Preprogrammed for use with IBT Board. Includes CASHMI PCB, 4 mounting screws, 16 ga. SS backing plate, membrane switches & gasket.
Direct Fired Air Movement Control Components
8164
[5 used]
1/4" Nylon Tubing - Used with the Modular Make-Up Air Units A1-D, A2-D, A3-D, A4-D, A5-D and the NHMUA1, NHMUA2, NHMUA3, AI (Price Per Foot). Type 12.
88130
[1 used]
1/4" Plastic Union Elbow for connecting airflow tubing to airflow probes (17045 & 17045A).
Direct Fired Sheet Metal Components
MLIFTL
[10 used]
LIFTING LUG
Exhaust Fan Vibration Isolators
800113-D60
[6 used]
Motor/Blower Frame Vibration Eliminator 1 3/8 Out. Dia. X 3/4" Tall, Rubber (Black) New Style, Shear 45 lbs, Compression 100 lbs. 3/8-16 x 5/8 dual studs. Durometer = 60
Exhaust Fan Wiring Options
8002
[56 used]
CONDUIT - 1/2" LT FLEX JIC. (Price per Foot)
Indirect Air Movement Control Components
RFS-4100-078
[1 used]
AIR FLOW SWITCH - Used for IBT air proving switch and clogged filter switch option. Factory set @ .25", adjustable.
NS2-1112-01
[3 used]
AIR FLOW SWITCH - Used with IBT units. Factory set @ .35". Induced draft fan airflow switch with bleed hole.
Indirect Fired Sheet Metal Components
IBT15CBBT
[2 used]
IBT 1-5 CABINET BOTTOM
IBT15DH
[4 used]
IBT 1-5 DOOR HOOK
IBT15DIB
[2 used]
IBT 1-5 DOOR INSULATION BRACKET
IBT15ELBK
[2 used]
IBT 1-5 ELECTRICAL BACK
IBT15ELSD
[4 used]
IBT 1-5 ELECTRICAL SIDE
IBT15ELTP
[4 used]
IBT 1-5 ELECTRICAL TOP
IBT15HC
[2 used]
IBT 1-5 HAT CHANNEL
IBT15LC
[4 used]
IBT 1-5 LOUVER COVER
IBT15TD
[6 used]
IBT 1-5 TIE DOWN
IBT15VFDB
[2 used]
IBT 1-5 VFD BACK
IBT34SDSB
[1 used]
IBT 3-4 Averaging Sensor Bracket
IBT35BSES
[2 used]
IBT 3-5 BOTTOM SIDE ELECTRICAL SIDE
IBT35BSHES
[2 used]
IBT 3-5 BOTTOM SIDE HE SIDE
IBT35IWB
[2 used]
IBT 3-5 INNER WALL BOTTOM
IBT35HE400IW
[4 used]
IBT 3-5 INNER WALL FOR MODULE WITH 400 MBH FURNACE
IBT35DFLID
[1 used]
IBT 3-5 LID DOUBLE FURNACE
IBT35SFLID
[1 used]
IBT 3-5 LID SINGLE FURNACE
IBT35MR
[4 used]
IBT 3-5 MAIN RAIL
IBT5ANG400
[3 used]
IBT 5 Air Angle for 400,000 BTU.
IBT5BKDH
[1 used]
IBT 5 BACK DOUBLE MODULE HINGED (FIRST MODULE)
IBT5BKSDH
[1 used]
IBT 5 BACK DOUBLE MODULE, SIDE DISCHARGE, HINGED (FIRST MODULE)
IBT5BOTTSD
[2 used]
IBT 5 BOTTOM SIDE DISCHARGE
IBT5FTH
[1 used]
IBT 5 FRONT HINGED
IBT5HE400FTD
[1 used]
IBT 5 HE 400 FRONT DOUBLE MODULE (SECOND MODULE)
IBT5HE400TF
[2 used]
IBT 5 HE 400 TOP FLASHING
IBT5HEBOTSD
[2 used]
IBT 5 HE BOTTOM SIDE DISCHARGE
IBT5HEEF
[2 used]
IBT 5 HE END FLASHING
IBT5HELFD
[1 used]
IBT 5 HE LEFT FLASHING DOUBLE FURNACE
IBT5HELFS
[1 used]
IBT 5 HE LEFT FLASHING SINGLE FURNACE
IBT5HELID
[2 used]
IBT 5 HE LID
IBT5HERF
[2 used]
IBT 5 HE RIGHT FLASHING
IBT5HS
[8 used]
IBT 5 HORIZONTAL SUPPORT
IBT5LD
[2 used]
IBT 5 LEFT DOOR
IBT5RD
[2 used]
IBT 5 RIGHT DOOR
IBT15BDPN
[3 used]
IBT Burner Condensate Drip Pan
IBTHE400DIV
[1 used]
IBT HE 400 DIVIDER
Indirect Flame Control Components
35-615937-997
[3 used]
24VAC Direct Spark Ignition Control. Combustion blower relay, 15 second trial for ignition, 60 second pre-purge and inter-purge, 120 second post-purge, 3 trials for ignition Recycle on loss of flame remote flame sense. Special extended flame integration time.
1-1437685-3-4
[2 used]
2TK2-48 Snap Track PVC Channel. 4 Inches Long.
Miscellaneous Electrical Parts
CAT5_3FT
[1 used]
3 Foot Long CAT5 Cable
800041
[2 used]
Bolt Whiz 10-32 X 1/2, SFB103212Z, Steel Grade 5 Minimum (3 Evenly Spaced Radial Marks)
8012A
[3 used]
J-BOX - SWITCH BOX - CY X 1/2.
800030
[2 used]
Nut Whiz 10-32, SFLN1032Z, Steel, Large Flange
FSCWIREHARNESS
[3 used]
Wire Harness for IBT Board. 1 Required Per Furnace.
Miscellaneous Heater Components
3M467J
[1 used]
Captiveaire Factory Direct sticker
Gasket-black
[5 used]
GASKETING - Weather Stripping w/PSA , Color BLACK, 1/8" X 1" (Price per foot)
17916
[90 used]
GASKETING - Weather Stripping w/PSA , Color Gray, 1/4" X 1" (Price per foot) (17916)
INSULATION/sq ft
[400 used]
INSULATION (Price per Sq Foot)
HG-OTA100
[12 used]
Removable Door Hinge used on Pollution Control Units and KB Blowers
Miscellaneous Hood Parts
SCREW 10-24X3/8 ZINC RD HD SLOTTED MS - DOOR HANDLE
[16 used]
SCREW 10-24X3/8 ZINC RD HD SLOTTED MS - Used on UC door handles and MUA door handles
104778
[1 used]
SEALANT - 10.3 oz Silicone Silver/Aluminum Sealant. 350 deg silicone used in hoods. (item #104778)
Pollution Control Gasket
397-91PSA-Foot
[3 used]
Gasketing - Thermeez Woven Ceramic Tape - 1/4" x 1" with adhesive back - Max Temp 1500°F. To be applied between fan base and grease duct. Per Foot.
R-10480-S-1/4" BY 1"-15
[33 used]
Saint Gobain Gasketing-SOFT, -1/4" by 1" , Red in Color. Backing is 3 M™ Adhesive 350 acrylic ideal for very high-bond strength to many surfaces. Comes in 15' rolls.
Pollution Control Hardware
90272A836
[16 used]
Zinc-Plated Steel Pan Head Phillips Machine Screw, 10-32 Thread, 1-1/2" Length Old AX # A0026555
90272A829
[8 used]
Zinc-Plated Steel Pan Head Phillips Machine Screw, 10-32 Thread, 1/2" Length
Product Manuals
MANUAL INDIRECT BENT TUBE
[1 used]
Manual for Commercial Indirect Fired Bent Tube Heater
RTU Miscellaneous Components
A7-10-351-20
[4 used]
Black Compression Handle Latch and Clasp
Supply Fan Miscellaneous Parts
SB6-4-RIVET
[130 used]
RIVET - 3/16" Diameter, .126 To .250 Grip Range, SB6-4 Button Head Steel/Steel. Replaced 800075.
Supply Fan Sheet Metal Components
B5SDBKIBTH
[1 used]
AHU 5 BACK with View Port FOR HINGED DOOR CONFIGURATIONS
B5SDBT
[1 used]
AHU 5 BOTTOM
B5BSIDBH
[1 used]
AHU 5 BOTTOM SIDE FOR HINGED DOOR CONFIGURATIONS
B5BSIDFH
[1 used]
AHU 5 BOTTOM SIDE FOR HINGED DOOR CONFIGURATIONS
B5925COL
[2 used]
AHU 5 COLLAR
B5DORLLH
[2 used]
AHU 5 DOOR LEFT DOOR LINER USED ON HINGED DOOR CONFIGURATIONS
B5DOORLH
[2 used]
AHU 5 DOOR LEFT DOOR USED ON HINGED DOOR CONFIGURATIONS
B5DORRLH
[2 used]
AHU 5 DOOR RIGHT DOOR LINER USED ON HINGED DOOR CONFIGURATIONS
B5DOORRH
[2 used]
AHU 5 DOOR RIGHT DOOR USED ON HINGED DOOR CONFIGURATIONS
B5DRSP
[2 used]
AHU 5 DOOR SUPPORT
B5DPRLBH
[1 used]
AHU 5 DRIP RAIL BACK SIDE
B5DPRLFH
[1 used]
AHU 5 DRIP RAIL FRONT SIDE
B5LTFPH
[1 used]
AHU 5 LEFT FRONT POST FOR HINGED DOOR CONFIGURATIONS
B5LIDD
[1 used]
AHU 5 LID
B5MNRL
[2 used]
AHU 5 MAIN RAIL
MCONWAS
[2 used]
Connecting Washer 12 Gauge 2-7/8" x 2-7/8"
M5EFLS
[2 used]
END FLASHING 55.6875X8 GALV18GA REV1
M5HSUP
[3 used]
HORIZONTAL SUPPORT BLOWER SUPPORTS FOR SIZE #5
M5LSUP
[1 used]
LID SUPPORT
MRDPLATE
[1 used]
Rotary Disconnect Plate for Supply Fans. 16 GA G90 Galvanized.
Thermostats/Sensors
A/CP-DO-240-QC
[1 used]
10K, Type II thermistor with 6" probe. 20' wire leads. (Replaces part# A/CP-DO-120-QC)
CP-HT-FA-12
[1 used]
High Temp 10K, Type II thermistor with average sensor wire 12' long operable up to 200F. No metal box included.
IBT Board
[2 used]
Staging and Modulating PCB for IBT heaters. Includes control of multiple furnaces, forced high fire, modulation. Used in conjunction with CAS HMI. Not a direct replacement for FVFAB.
Transformers
BE161640GEK0018
[2 used]
TRANSFORMER - Low 40VA Voltage Transformer Used for 120v Primary and 24v Secondary.
Transformers (Heater Parts)
BE141620GEK0032
[1 used]
TRANSFORMER - 120V-24V 20VA with QC's Prod. 50/60Hz
Curbs
Part
CRB52.75x14INS ROOF CURB - 52.75" Square X 14" High, Insulated
CRB52.75x18INS ROOF CURB - 52.75" Square X 18" High, Insulated
CRB52.75x20INS ROOF CURB - 52.75" Square X 20" High, Insulated
CRB52.75x24INS CURB - 52.75" Square X 24" High, Insulated
CRB52.75x36INS CURB - 52.75" Square X 36" High, Insulated
Options
Part
CSMDTIL Commercial Smoke Detector Interlock (Detector By Others)
D4120-DST-1.5-C Duct Mounted Smoke Detector For Commercial Direct Fired Heater. Complete with detector (D4120) and sampling tube (DST-1.5). Ships Loose
Show parts
CABHTR200W2X Control panel enclosure heater for two IBT burner modules, includes (2) 200w, 120v heater. Recommended for winter design temperature less than 0°F.
Show parts
IBT Condensation Kit- 3 Factory Assembled IBT Condensation Drain Kit for 3 Furnace Units. Required for Winter Design Temp of 0 degrees F and lower. Kit includes drain assembly, mounting screws, zip ties, and heat tape for triple furnace unit. Field piping from unit by others.
Show parts
Ecoat-5-C Size 5 Cooling Coil Ecoating option for standard MPU, DX and Chilled Water Coils. Adds 5-6 week lead time.
IACT-CC Intake Air Single Stage Cooling Thermostat Mounted in Unit - Set Point For Thermostat Should Be 85°F for MPU, 60°F for MPU-AC. Low Limit cooling thermostat.
Show parts
IBT-EC-FPDK-Evap Freeze Protection Drain Control kit for Evaporative Coolers. Includes 3-Way water solenoid valve 8316G064 (shipped loose), Pressure switch installed upstream of 2way solenoid in unit, Brass Tee and 2 NPT half inch nipples. Field wiring required by others for 3-way valve. For both Celdek and Standard V-bank type Configurations.
Show parts
CD-G-54x45x12 Glasdek Media for size 5 celdek evaporative cooler intake. 54in wide x 45in tall x 12in thick.
PRESSGA35-2 Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size, Quantity 2 for 2 Furnace Modules.
Show parts
PRESSGA-0-10-3 Gas Pressure Gauge, 0 to +10 Inches Wc., 2.5" Diameter, 1/8" Thread Size, Rear Thread, For 3 Furnaces
Show parts
143-80-2-1-G-5/8-2 2 Gas regulators for Double Furnace Modules - 1" diameter thread size, 10 PSI Inlet Gas Pressure. 1180 CFH, 6-14" w.c. Outlet Pressure. Includes 173-62-021-17 "Green" spring and 5/8" 10 PSI orifice.
Show parts
Custom 143 Regulator-Mod-2 2 Gas Regulators for Gas Trains with 10 lbs or greater inlet gas pressure. Inlet gas pressure must be specified. Custom sized by factory. Ships loose. (143)
HGP-A-3 High Pressure Gas Switch (2" - 16" WC) Factory set at 5" w.c. (Natural) or 12" w.c. (L.P.) 3 Switches for Indirect units with 3 furnaces.
Show parts
LGPSO-2 Low Pressure Gas Switch (1" - 6" WC) Factory set at 2" w.c. Includes 2 switches for Indirect Units with 2 Modules
Show parts
EGL-MUA Extended Grease Lines for Commercial MUA Fans. Grease Zerk fittings installed on outside of fan housing, directly below disconnect switch. Requires (2) 25/64" holes drilled in cabinet exterior.
Show parts
XB-2 Extra Set of V-Belts. Only to be ordered as fan option at time fan is ordered.
MIAMI-DADE NOA-2 Supply Miami Dade Impact and Wind Load Certification +30 / -130 PSF - Miami Dade County Product Control Approved. Florida Building Code approval. Roof Mount Exhaust Curbs up to 20" high must be 18 gauge Aluminized.
Single Point Connection - 2 Single Point Electrical Connection for all IBT Heaters with 2 modules. QNTY 2 750va Transformers Used. If a Non-DCV Prewire is used on the IBT Heater, the #28, #47, "MA", or "E2" Option Prewire must be selected. Do not provide supply starter in prewire.
Separate 120V Connection - 2 Separate 120V Electrical Connection for all IBT Heaters with 2 modules for Standing power. 120V must be run by electrician from building panel to mua switch.
IBT EVAP INTERLOCK Layer Control for IBT Evap
Show parts
IBT ROOM OVERRIDE Option Control for IBT/RTU Scheduling. Do not order as a part.
IFHIELOR Specially sized orifices for applications above 2,000', notify engineering.
Show parts
IHC-IDF5 Indoor Hanging Cradle For The Size 5 Indirect Fired Unit. 2 HSB750 Hanging Isolators per Uni-Strut Included.
Show parts
Blower Delay Start Blower Delay Start. Allows Indirect Furnace to pre-heat before blower operation. Factory set at 90 seconds. TI-11 set at 20 seconds. TI-12 set at 90 seconds.
Burner-Interlock-IBT/RTU Burner Interlock Input. Locks out cooling when interlock is energized.
CLCOMM_REV04 CASLink building monitoring system communications module. Requires internet & field wired ethernet connection or 3G cellular service. Includes Rev 3 Comm Module, RJ45 to modbus converter, 3 FT cat5 cable, and 1 FT of shielded twisted pair.
Show parts
AC-Interlock-IBT/RTU Cooling Interlock Input to PCB Board. Locks out burner circuit when AC is energized.
DDC-IP BACnet Monitoring Remote IP BACnet monitoring for supply fans.
Show parts
DDC-LONWorks Monitoring Remote LONWorks monitoring for supply fans.
Show parts
DDC-MSTP BACnet Monitoring IBT Remote MSTP BACnet monitoring for IBT
Show parts
FECONTAAFS Field Wired Exhaust Contactor After Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP 230v, 15HP max. 460V, 15HP max. 575V or (4) Dry Interlocks. Overload not Included
Show parts
FECONTBAFS Field Wired Exhaust Contactor Before Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP max 230v, 15HP max. 460V. Overload not Included
Show parts
EXHSTARTER4-5AAFS Exhaust Fan Starter Installed in size 4 or 5 heaters powered after airflow switch
EXHSTARTER4-5BAFS Exhaust Fan Starter Installed in size 4 or 5 heaters powered before airflow switch
Exhaust on Fire Exhaust on Fire
OCCUPIED SCHEDULING Occupied Scheduling Defaulted for IBT/RTU.
OPPSIDE-H-CTRLS Mount motor and controls on opposite side of heater.
Supply Fan Preset Speed Supply Fan Preset Speed Input to PCB. Field Wired.
UNOCCUPIED SCHEDULING Unoccupied Scheduling Defaulted for IBT/RTU.
CLOGFILTHMI Clogged Filter Switch with Notification on HMI
Show parts
CVOUTLET GFCI 15 amp Convenience Outlet For Heater Enclosure. Power supply by others - Includes receptacle and J box.
EXTENDED-DROP Extended Drop for Commercial Heaters and Supply Fans. Extends the power and remote panel connections to the unit to 20' of total length.
CVOUTLET6IBT5 GFCI 6 amp Powered Convenience Outlet For IBT 5 units with 208/230/460 power. Includes receptacle, jbox, cover, and transformer.
Show parts
MB5-IBT-Analog Mixing Box for Size 5 IBT. Actuator Control By 0-10V Input to IBT Board by others.
Show parts
MB5-IBT-2P Mixing Box for Size 5 IBT. Actuator Control By Field Wired Switch.
Show parts
MB5-IBT-MAN Mixing Box for Size 5 IBT. Actuator Control By 0-10V Output on IBT Board.
Show parts
MB5-IBT-OA Mixing Box for Size 5 IBT. Actuator Control By 0-10V Output On IBT Board to Maintain Desired Outdoor Air %.
Show parts
MB5-IBT-SCHEDULE Mixing Box for Size 5 IBT. Actuator Control By Schedule.
Show parts
MB5-SP Mixing Box for Size 5 Modular Supply Fan. Actuator Control by Static Pressure. Photohelic included.
Show parts
A5IBTUPDISCH Up Discharge Construction Size 5 IBT
A5-D-MBDD INS Motorized Back Draft Insulated Damper 43" X 43" for Size 5 Standard & Modular Heater Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, NFBUPS Actuator Included. Insulated blades and frame. Thermally broken blades.
Show parts
A5-D-MBDD Motorized Back Draft Damper 43" X 43" for Size 5 Standard & Modular Heater Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, NFBUPS Actuator Included
Show parts
A5-MBDD-SL Motorized Back Draft Discharge Damper Shipped Loose 43" X 43" for Size 5 Units w/Extended Shaft, Standard Galvanized Construction, 3/4" Rear Flange, Low Leakage, NFBUPS Actuator Included, Field Installation Required. Damper, actuator & actuator cover (p/n ACTCOVERMOD) factory assembled.
Show parts
Full Crating for Heater Full crating for commercial heaters for shipping.
ENAM-3 Tan Enamel Coating (exterior walls/roof) For Heaters with 22"-25" blower wheels, includes casing and intakes. Consult factory for other colors. Sherwin Williams p/n F75KXN5809-4347, (AX = A0006229)
DX 5-1 KIT-R410A DX 5-1 Kit R410A. Dual Circuit 30 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
DX 5-2 KIT-R410A DX 5-2 Kit R410A. Dual Circuit 40 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
DX 5-3 KIT-R410A DX 5-3 Kit R410A. Dual Circuit 50 Ton. Includes Filter Drier, Sight Glass, and Thermal Expansion Valve for DX units. Installation by others. Includes R410A TXV. Installation by others. Includes R410A TXV.
Show parts
MELIM-5 Size 5 Moisture Eliminator Option for DX Coils, MPUs and Chilled Water Coils - allows cooling coil face velocity to increase to 650 fpm. Increases cooling coil max cfm to 16750 cfm.
Show parts
Damper Presets Damper Preset Position Input to PCB. Field Wired.
Show parts
D-Hanger Curb Duct Hanger - 1-1/4" Angle Iron Frame Welded to Curb to support standard size ductwork. Priced per curb. Only available when curb assembly is ordered.
MB5-MERV 13-EXTRA Extra set of MERV 13 filters for Size 5 Mixing Box. Uses 12 14.5 x 19 x 2 inch filters.
Show parts
MB5-MERV 8-EXTRA Extra set of MERV 8 filters for Size 5 Mixing Box. Uses 12 14.5 x 19 x 2 inch filters.
Show parts
MB5-MERV 13 MERV 13 filter option for Size 5 Mixing Box or Condenser Support. Mixing Box or Condenser Support must be selected for this option. Uses 12 14.5 x 19 x 2 inch filters.
Show parts
MB5-MERV 8 MERV 8 filter option for Size 5 Mixing Box or Condenser Support. Mixing Box or Condenser Support must be selected for this option. Uses 12 14.5 x 19 x 2 inch filters.
Show parts
Dedicated Combustion-2 8 inch Round Take-Off Installed in both Lids of IBT modules for dedicated combustion air on indoor units. Control side door constructed without louvers. All combustion ductwork by others.
Show parts
DBWSLC-B-5 Double Wall Steel Liner for Blower. Includes Roof, Floor, and Doors Double Wall Liners.
Ship Modules Separate Ship Modules Separate Option for Modular Units
MB5-TOPRN Top Return Option for Size 5 Mixing Box - No Filter Option Available. Use top return lid and standard DF base.
Show parts
FIRESTAT-DISCHARGE- Discharge Firestat. Set to 240°F
FREEZESTAT- Freezestat factory set at 35°F and 10 minutes.
FIRESTAT-INTAKE- Intake Firestat. Set to 135°F
IBT/DF/RTU Nema 4x remote Space Sensor Nema 4x Remote Room Sensor Option. Wall Mountable 10k Room Sensor Included.
Show parts
IBT/RTU remote Space Sensor Remote Room Sensor Option. Wall Mountable 10k Room Sensor Included.
Show parts
Blower Delay Stop Blower Delay Stop. Allows supply fan to run after the burner has shut off Factory set at 90 secs for indirect 30 secs for direct.
VBI-CSF "Insulation" for V-bank Intake Option.
VB-DS-MB5 V-bank Downstream of Mixing-Box Option Size 5
DCVWP-SUPPLY Separate 120VAC Wiring Package for Make-Up Air Units. Option must be selected when mounting VFD in prewire panel or with DCV package. Provides separate 120VAC input to supply fan. This 120V signal must be run by electrician from DCV to mua switch.
Show parts
VAV-WP-VDC-INPUT-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. 0-10VDC Speed Control Variable Frequency Drive Included
VAV-WP-BSPC-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Building Static Pressure Variable Frequency Drive Control Included
Show parts
VAV-WP-MC-MUA VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. Manual Speed Control Variable Frequency Drive Included
VFDINUNIT VFD factory mounted and wired in unit control vestibule.
 
 
 