Sign In         Specifying Software      
 
    Home        About Us        Contact Us        Help Buy Online or Call 1-800-476-5888  
 
 
TTV-M 225 with 72" burner Parts
Motors, Pulleys, & Motor Specific Parts
Motor HP Phs Voltage FLA Shaft Frame Weight RPM Vendor
DTP0154 15.000 3 208-230/380/460 V 40.3-36.4/22.7/18.2 1.625" 254T 231 lbs 1755 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0204 20.000 3 208-230/460 V 53.7-48.6/24.3 1.625" 256T 269 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0254 25.000 3 208-230/460 V 65-58.8/29.4 1.875" 284T 339 lbs 1765 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0304 30.000 3 208-230/460 V 76.7-69.4/34.7 1.875" 286T 283 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DHP0404 40.000 3 208-230/460 V 102.4-92.6/46.3 2.125" 324T 338 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DHP0504 50.000 3 208-230/460 V 128.9-117/58.3 2.125" 326T 440 lbs 1775 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0154 15.000 3 190/208-230/380/460 V 41.8/38.2-34.5/20.9/17.3 1.625" 254T 267 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
01518ET3H254T-W22 15.000 3 575 V 14.4 1.625" 254T 347 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
02018ET3H256T-W22 20.000 3 575 V 19.3 1.625" 256T 396 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0204 20.000 3 190/208-230/380/460 V 55.7/50.8-46/27.8/23 1.625" 256T 311 lbs 1760 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0254 25.000 3 208-230/460 V 64.3-58.2/29.1 1.875" 284T 399 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
02518ET3H284T-W22 25.000 3 575 V 23.6 1.875" 284T 412 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
03018ET3H286T-W22 30.000 3 575 V 28.1 1.875" 286T 450 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0304 30.000 3 208-230/460 V 75.8-68.6/34.3 1.875" 286T 436 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0404 40.000 3 208-230/460 V 102.3-92.6/46.3 2.125" 324T 661 lbs 1770 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
04018ET3H324T-W22 40.000 3 575 V 37.7 2.125" 324T 574 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
05018ET3H326T-W22 50.000 3 575 V 47.4 2.125" 326T 595 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0504 50.000 3 208-230/460 V 125-113.8/56.9 2.125" 326T 686 lbs 1770 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts

The manufacturer reserves the right to use alternate motors from alternate vendors that meet the operating requirements of the fan but may have slightly different specifications.
Intakes & Intake Parts
Part
IV7-NF-IS Intake Screen - CFA7 Unit Intake Screen
IV7-O-VB2"EZ-IS V-BANK - 43.25" Width X 142.5" Length X 32" Height for Vertical Industrial, Standard 2" EZ Filter With Filter Intake Screen, Max CFM = 56,000
Show parts
IV7-O-VB2"TA13-IS V-BANK - 43.25" Width X 142.5" Length X 32" Height for Vertical Industrial, Standard 2" Pleated Filter With Filter Intake Screen, MERV 13 V-Bank Filters. Max CFM = 56,000
Show parts
IV7-I-VB2"TA13-IS V-BANK - 43.25" Width X 142.5" Length X 32" Height for Vertical Industrial, Standard 2" Pleated Filter With Filter Intake Screen, MERV 13 V-Bank Filters. Max CFM = 56,000
Show parts
IV7-I-VB2"TA-IS V-BANK - 43.25" Width X 142.5" Length X 32" Height for Vertical Industrial, Standard 2" Pleated Filter With Filter Intake Screen, MERV 8 V-Bank Filters. Max CFM = 56,000
Show parts
IV7-O-VB2"TA-IS V-BANK - 43.25" Width X 142.5" Length X 32" Height for Vertical Industrial, Standard 2" Pleated Filter With Filter Intake Screen, MERV 8 V-Bank Filters. Max CFM = 56,000
Show parts
IV7-I-VB2"EZ-IS V-BANK - 92.25" Width X 36.25" Length X 30" Height for Industrial Vertical, Standard 2" EZ Filter With Filter Intake Screen, Max CFM = 56,000
Show parts
Temperature Controls

No Temperature Controls Found.

Gas Manifold Parts

No Gas Manifold Parts Found.

Blower
Part
A225-25HM Two 25" Blowers - Enamel finish, pillow block bearing, 30000-56000, 50 HP, 2 3/16 Shaft, 900 MAX RPM, used in heated and non-heated supply fans
Burner
Part
R7-9-72M Direct-fired burner assembly. 3,900,000 BTU/HR Maximum, 130,000 minimum. 72" long. Used in size 4 industrial vertical and horizontal re-circulating direct-fired heaters. Used for both Natural and Propane Gas. Pilot/Flame Rod/Spark Assembly included.
 
1190850
[1 used]
BURNER PART - "BRUTE" PILOT ASSEMBLY W/ SPARK & FLAME ROD. Pilot hole size is drill #50 (.070 diameter) (342B) (A0003270) Includes pack of boots and hardware. REPLACES 1190870
 
1060810
[1 used]
BURNER PART - 12" STRAIGHT BACK INLET SECTION - HMA-2A (Aluminum)
 
1010810
[5 used]
BURNER PART - 12" STRAIGHT SECTION - HMA-2A (Aluminum)
 
1372-52
[2 used]
BURNER PART - BLANK END FLANGE - ALUMINUM
 
1354-50
[1 used]
BURNER PART - SS End Plate
 
1354-60
[1 used]
BURNER PART - SS End Plate W/ PILOT MOUNT
Replacement Parts
Part
C710V1AB
[1 used]
Blower section frame for size 7 industrial vertical direct fired heater
C700V1AB
[1 used]
Burner section for size 7 vertical industrial direct fired units
C7096V1W
[1 used]
Wall panel side burner section for Size 7 Industrial Vertical Recirculating Heater
PN10-10RX-L
[1 used]
Yellow Ring Expanded Entry for GTO Cable - Panduit Used on ignition transformers
HMI_Bracket
[1 used]
20 GA. Galvanized. Used on IBT controls
Controller&HMI
HMI_01_MUA_POPULATED
[1 used]
HMI assembly. Preprogrammed for use with MUA Board. Includes CASHMI PCB, 4 mounting screws, 16 ga. SS backing plate, membrane switches & gasket. HMI should have populated RH sensor.
Coupler
2 3/16" BUSHING SF
[2 used]
2 3/16" BUSHING SF will take 2 to make up coupler
11B FLANGE
[2 used]
Flange 11B will take two to make up coupler, match with 11E sleeve and SF bushing.
11E SLEEVE
[1 used]
SLEEVE 11E will take one to make up coupler. Match with two 11B flanges.
Direct Fired Air Movement Control Components
17045A
[4 used]
Airflow Switch Components Cleveland Controls Airflow Probe 4".
Direct Fired Components
85000.005
[8 used]
PLATE, INDUSTRIAL LIFTING EYE 3/8", Standard for Size 2-9 Industrial Vertical Units
Direct Fired Flame Control Components
M4RT1
[1 used]
Fireye Flame Safety Control. Direct replacement for M series 2. Pre-purge preset 5 Sec. PTFI preset 10 Sec. Recycles once only after flame signal loss. Wiring connections are identical to M series 2.
Direct Fired Sheet Metal Components
C1000V1M
[12 used]
Mounting brackets used to fasten unit sections and to vertical stand on vertical industrial units. 2 sets used on singles, 4 on split singles, 6 on twins. Set of 2, includes fasteners.
Gasket Kit
CFA 7 Gasket Kit
[1 used]
Gasket Kit for CFA 7 Electrical and Blower Doors
Miscellaneous Electrical Parts
CAT5_3FT
[1 used]
3 Foot Long CAT5 Cable
MUA Board
[1 used]
PCB for use in heaters. Used with CAS HMI.
Miscellaneous Heater Components
206525
[1 used]
Yellow Label Sheet Package for Industrial MAUs.
Product Manuals
MANUAL INDUST 1
[1 used]
Manual for Re-Circulating Industrial Direct Fired Heaters.
Thermostats/Sensors
A/CP-DO-240-QC
[2 used]
10K, Type II thermistor with 6" probe. 20' wire leads. (Replaces part# A/CP-DO-120-QC)
Transformers
1092TYPEF
[1 used]
Ignition Transformer 120V, 180VA, Output 6000 Volts Used with direct fired heaters
BE161640GEK0018
[1 used]
TRANSFORMER - Low 40VA Voltage Transformer Used for 120v Primary and 24v Secondary.
Curbs
Part
VMSI-7 Insulated Enclosed Vertical stand for Size 7 Industrial Vertical Heaters (indoor). 50.5" Wide x 147" Long x 76" High
Options
Part
SPRCM-MUA Static Pressure Recirculating Damper Control (Mounted in Unit, preset to: -0.01 and 0.02) Used with MUA board
Show parts
ETPRC Electric Two Position Recirculating Damper Control
Show parts
MPRC Manual Potentiometer Re-circulating Damper Control - - Ship loose in 2x4 j-box
Show parts
PRRC Building Automation System Re-circulating Damper Control. Accepts 2-10VDC signal for damper position.
Show parts
SRRDC Schedule damper control - used with the MUA board.
Show parts
SPRC-NP Static Pressure Recirculating Damper Control (Pressure Control By Others)
Show parts
SPRC Static Pressure Recirculating Damper Control (Shipped Loose, preset to: -0.01 and 0.02)
Show parts
SPRCM Static Pressure Recirculating Damper Control (Mounted in Unit, preset to: -0.01 and 0.02)
Show parts
AALARM Audible Alarm, 120v,(Alarm sounds on flame failure).
Show parts
6631T18 Combustible Gas and Carbon Monoxide Detector 120VAC input. On-Board 10A, 250V Relay and 85db Audible Alarm. 150ppm CO, 17ppm H2, 5000 ppm Methane, 35ppm Propane. (HIC-822). 10,000 cubic feet recommended coverage per detector.
CODTIL Detector/Alarm Interlock (By Others)
D4120-DST-1.5 Duct Mounted Smoke Detector For Direct Fired Heater. Complete with detector (D4120) and sampling tube (DST-1.5). Ships Loose.
Show parts
SMDTIL Smoke Detector Interlock (By Others)
XBINDTWIN Extra Set of V-Belts For Twin Industrial Units. Only to be ordered as fan option at time fan is ordered.
EGL-7 Size 7 Industrial Heater Extended Grease Lines
Show parts
CABHTR100WNC Control panel enclosure heater, includes 100w, 120v heater. Recommended for winter design temperature less than 0°F. Operates on PCB controls in IBT Single Modules or RTU
Show parts
CABHTR200W Control panel enclosure heater, includes 200w, 120v heater and thermostat (10 degree setting). Requires convenience outlet option (power by others). Recommended for winter design temperature less than 0°F. - Old Controls
Show parts
NON SILICONE Fan housing assembled without the use of silicone caulk. Primarily used for paint booth applications. Use Acrylic Latex Caulk , P/N A0011848.
POC Proof of closure option for industrial direct fired heaters. One motorized valve must be included in gas manifold.
CINSUL-7 Size 7 Industrial Heater Casing Insulation with Steel Liner
C7BURNCAP Burner section cap for size 7 Industrial Vertical unit with 222 or 225 blowers, protects burner section from weather prior to install. There is no warranty for water damage in burner and/or gas train due to improper storage prior to install.
Cooling Interlock Cooling Interlock Between Remote Panel and Heater
CIR-IN Cooling Interlock Relay Mounted in Unit - After Air Proving and Intake Air Stat.
Show parts
A225SDAD-C 180° Side Discharge Diffuser (A225)
DSD-225V Straight Run Diffuser Ductwork for A225 Diffuser. 3 Feet Long, 18ga.
NON_FUSED_DISC_IND_SEP120 Non-Fused Disconnect Switch for Industrial Make Up Air Units, Sep 120v Connection.
NON_FUSED_DISC_IND_SP Non-Fused Disconnect Switch for Industrial Make Up Air Units, Single Point Connection.
PRESSGA15 Gas Pressure Gauge, 0-15PSI, 2.5" Diameter, 1/4" Thread Size
PRESSGA35 Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size
PRESSGA5 Gas Pressure Gauge, 0-5#, 2.5" Diameter, 1/4" Thread Size
PRESSGA-5-0+15 Gas Pressure Gauge, -5 to +15 Inches Wc., 2.5" Diameter, 1/4" Thread Size
PRESSGA35 Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size
PRESSGA15 Gas Pressure Gauge, 0-15PSI, 2.5" Diameter, 1/4" Thread Size
GMH-A4-4-4 High Gas Pressure Switch (1" - 20" WC) Factory set at 8" w.c. Replaces part HGP-A.
LGPSO Low Pressure Gas Switch (1" - 6" WC) Factory set at 2" w.c.
Show parts
Gas Strainer 1 1/2" Ship Loose Gas Strainer. To be installed upstream of unit connection. 1 1/2" Connection
Show parts
Gas Strainer 1 1/4" Ship Loose Gas Strainer. To be installed upstream of unit connection. 1 1/4" Connection
Show parts
Gas Strainer 1" Ship Loose Gas Strainer. To be installed upstream of unit connection. 1" Connection
Show parts
Gas Strainer 2 1/2" Ship Loose Gas Strainer. To be installed upstream of unit connection. 2 1/2" Connection
Show parts
Gas Strainer 2" Ship Loose Gas Strainer. To be installed upstream of unit connection. 2" Connection
Show parts
CLCOMM_REV04 CASLink building monitoring system communications module. Requires internet & field wired ethernet connection or 3G cellular service. Includes Rev 3 Comm Module, RJ45 to modbus converter, 3 FT cat5 cable, and 1 FT of shielded twisted pair.
Show parts
SAMSUNG-MODBUS AUXILIARY MODBUS CONNECTION FOR USE WITH SAMSUNG CONTROLLER
DDC-IP BACnet Monitoring Remote IP BACnet monitoring for supply fans.
Show parts
DDC-MSTP BACnet Monitoring Remote MSTP BACnet monitoring
Show parts
Dry Mode Dry Mode
Show parts
FECONTAAFS Field Wired Exhaust Contactor After Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP 230v, 15HP max. 460V, 15HP max. 575V or (4) Dry Interlocks. Overload not Included
Show parts
FECONTBAFS Field Wired Exhaust Contactor Before Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP max 230v, 15HP max. 460V. Overload not Included
Show parts
FECONTBAFS Field Wired Exhaust Contactor Before Airflow Switch. Rated 23 Amps. Starts up to (2) Single Phase Motors. 2HP max. 115V, 3HP max. 240V. Starts one Three Phase Motor. 5HP max. 208V, 7.5HP max 230v, 15HP max. 460V. Overload not Included
Show parts
Exhaust on Fire Exhaust on Fire
EXHRELAYBAFS Exhaust Relay Before Airflow Switch. Provides 2 sets of NO to be used as a start command interlock for exhaust fans.
Show parts
LFS Low Fire Start. Allows the burner circuit to energize when the modulation control is in a low fire position.
MAN RES FSC Manual reset of flame safety controller. Used to meet Canada requirement. Flame safety will not reset on cycle of power. Dips 1,2,3,5 closed, 4, 6 open standard settings.
OCCUPIED SCHEDULING Occupied Scheduling Defaulted for IBT/RTU.
OPPSIDE-TWINIH-CTRLS Mount motor and controls on opposite side of heaters with double blowers
INSUEXPV Supply and exhaust (exhaust by others) proving for industrial make up air units. Includes timed relay, requires field supplied exhaust interlock.
Show parts
Supply Fan Preset Speed Supply Fan Preset Speed Input to PCB. Field Wired.
CLOGFILTHMI Clogged Filter Switch with Notification on HMI
Show parts
CLOGFILT Clogged Filter Switch with Light on Remote Panel
Show parts
PBCLOGFILT Clogged Filter Switch with Light on Paint Booth Control Panel
Show parts
Control Vestibule LED Lights Control Vestibule LED Lights Used on Industrial Units.
Show parts
CVOUTLET GFCI 15 amp Convenience Outlet For Heater Enclosure. Power supply by others - Includes receptacle and J box.
INDPCVOUTLET GFCI 15 amp Powered Convenience Outlet For Industrial units with 208/230/460 power. Includes receptacle, jbox, cover and transformer. Not available with ship loose vfd.
Show parts
N.O. Contacts Extra set of N.O. contacts on supply starter.
Shaft Grounding Ring Option Shaft Grounding Ring Option
A225DDS-C INS External Side Discharge Insulated Damper for size 7 Vertical industrial units with (2)25" blowers. Includes actuator. Insulated blades and frame. Thermally broken blades. Non-stock option, lead time 6 weeks.
Show parts
A225DD-DM External Discharge CD60 Damper for size 7 industrial units with (2)25" blowers. Includes actuator.
Show parts
FIELDDMP(S) Field Supplied Damper(s) Indicated By Others
A225DDS-C External Side Discharge CD60 Damper for size 7 Vertical industrial units with (2)25" blowers. Includes actuator.
Show parts
C7 ID Size 7 Vertical Industrial Heater Intake Damper. Includes Actuator. Indoor Applications Only. Ships Loose.
Show parts
A225DDU-C Ship Loose External Up Discharge CD60 Damper for size 7 Vertical industrial units with (2)25" blowers. Includes actuator.
Show parts
Full Crating for Untempered Fan Full crating for untempered fans for shipping.
PB-VFD-BSPC-AB Auto Balance Exhaust VFD Static Pressure Control (preset to: -0.01 and 0.02)
Show parts
PB-VFD-RMP-MB Manual Balance Exhaust VFD Control
PB-LC Paint Booth Lighting Circuit Switch Only.
PB-LC-AO Paint Booth Lighting Circuit Switch and Auto Off in Cure Mode.
PB-PURGE Paint Booth Purge Cycle with Light
CONSERVETMR Spray mode energy conservation timer, reduces cfm's if spray not active. Factory set for 5 minutes. Requires mau vfd.
Show parts
ENAM-7 Tan Enamel Coating (exterior walls/roof) For Heaters with 222"-225" blower wheels, includes casing and intakes. Consult factory for other colors. Sherwin Williams p/n F75KXN5809-4347, (AX = A0006229)
NOSTOVVFDM-TWIN-PCB No starter/overloads (PCB Controls) installed in unit, recirculating profile package, includes VFD for soft start operation (ship loose is default).
Show parts
NOSTOVVFDM-TWIN No starter/overloads installed in unit, recirculating profile package, includes VFD for soft start operation (ship loose is default).
Show parts
NOSTOVM-TWIN No starter/overloads installed in unit, non-fused disconnect switch, vfd for soft start by others, recirculating profile package provided.
FIRESTAT-DISCHARGE- Discharge Firestat. Set to 240°F
FIRESTAT-DISCHARGE Discharge Firestat for Heaters Set to 240°F - Old Controls
Show parts
FREEZESTAT Freezestat
FRSTAT-20 Freezestat With 20' Sensor. Factory set at 35°F and 10 minutes.
Show parts
FRSTAT-20-LTL Freezestat With 20' Sensor and Low Temp Light on Remote Panel. Factory set at 35°F and 10 minutes.
Show parts
FRSTAT-20-LTL Freezestat With 20' Sensor and Low Temp Light on Remote Panel. Factory set at 35°F and 10 minutes.
Show parts
FIRESTAT-INTAKE- Intake Firestat. Set to 135°F
FIRESTAT-INTAKE Intake Firestat for Heaters Set to 135°F - Old Controls
Show parts
IBT/RTU remote Space Sensor Remote Room Sensor Option. Wall Mountable 10k Room Sensor and Wire Included.
Show parts
PRE-PT Pre purge (set at 30 seconds) allowing the blower to purge the inside of the heater.
C7VBI Size 7 Vertical Industrial Vbank Insulation Upgrade
CRAF-7-C 2" Cleanable Return Air Filter Section for Size 7 Industrial Vertical Direct Fired Heater
Show parts
TRAF-7-C 2" Throwaway Return Air Filter Section for Size 7 Industrial Vertical Direct Fired Heater
Show parts
LOADREACTORININD Mount Load Reactor in Industrial Mau (Does not include reactor cost, just mounting).
 
 
 

Security Policy     Privacy Policy     Legal Notice     Warranty     Return Policy
Copyright ® 2003-2014 Thermotek All Rights Reserved.