 Electric Heating Coil (Modulating)
 
     
Thermotek
www.thermotek.com
     
** Please call for pricing or to purchase **
 
Part # & Description
EMC1-10KW2401
Electric Duct Insert for Size 1 Enclosure. 240V 1 phase, 10 KW maximum - 1 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 15.50" wide and 17.75" tall.

 
EMC1-20KW2401
Electric Duct Insert for Size 1 Enclosure. 240V 1 phase, 20 KW maximum - 2 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 15.50" wide and 17.75" tall.

 
EMC1-20KW2403
Electric Duct Insert for Size 1 Enclosure. 240V 3 phase, 20 KW maximum - 2 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 15.50" wide and 17.75" tall.

 
EMC1-20KW4803
Electric Duct Insert for Size 1 Enclosure. 480V 3 phase, 20 KW maximum - 1 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 15.50" wide and 17.75" tall.

 
EMC1-35KW2403
Electric Duct Insert for Size 1 Enclosure. 240V 3 phase, 35 KW maximum - 5 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 15.50" wide and 17.75" tall.

 
EMC1-35KW4803
Electric Duct Insert for Size 1 Enclosure. 480V 3 phase, 35 KW maximum - 2 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 15.50" wide and 17.75" tall.

 
EMC1-35KW6003
Electric Duct Insert for Size 1 Enclosure. 600V 3 phase, 35 KW maximum - 1 modulating stage, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 15.50" wide and 17.75" tall.

 
EMC1-36KW2403
Electric Duct Insert for Size 1 Enclosure. 240V 3 phase, 36 KW maximum - 3 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 15.50" wide and 17.75" tall.

 
EMC1-40KW2401
Electric Duct Insert for Size 1 Enclosure. 240V 1 phase, 40 KW maximum - 4 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 15.50" wide and 17.75" tall.

 
EMC1-50KW4803
Electric Duct Insert for Size 1 Enclosure. 480V 3 phase, 50 KW maximum - 2 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 15.50" wide and 17.75" tall.

 
EMC1-72KW4803
Electric Duct Insert for Size 1 Enclosure. 480V 3 phase, 72 KW maximum - 2 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 15.50" wide and 17.75" tall.

 
EMC1-76KW6003
Electric Duct Insert for Size 1 Enclosure. 600V 3 phase, 76 KW maximum - 2 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 15.50" wide and 17.75" tall.

 
EMC2-100KW4803
Electric Duct Insert for Size 2 Enclosure. 480V 3 phase, 100 KW maximum - 4 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 22.63" wide and 23.63" tall.

 
EMC2-119KW6003
Electric Duct Insert for Size 2 Enclosure. 600V 3 phase, 119 KW maximum - 3 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 22.63" wide and 23.63" tall.

 
EMC2-45KW2403
Electric Duct Insert for Size 2 Enclosure. 240V 3 phase, 45 KW maximum - 3 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 22.63" wide and 23.63" tall.

 
EMC2-73KW4803
Electric Duct Insert for Size 2 Enclosure. 480V 3 phase, 73 KW maximum - 3 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 22.63" wide and 23.63" tall.

 
EMC2-73KW6003
Electric Duct Insert for Size 2 Enclosure. 600V 3 phase, 73 KW maximum - 2 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 22.63" wide and 23.63" tall.

 
EMC3-122KW4803
Electric Duct Insert for Size 3 Enclosure. 480V 3 phase, 122 KW maximum - 3 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 29.50" wide and 29.63" tall.

 
EMC3-122KW6003
Electric Duct Insert for Size 3 Enclosure. 600V 3 phase, 122 KW maximum - 3 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 29.50" wide and 29.63" tall.

 
EMC3-143KW4803
Electric Duct Insert for Size 3 Enclosure. 480V 3 phase, 143 KW maximum - 4 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 29.50" wide and 29.63" tall.

 
EMC3-175KW6003
Electric Duct Insert for Size 3 Enclosure. 600V 3 phase, 175 KW maximum - 4 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 29.50" wide and 29.63" tall.

 
EMC3-52KW2403
Electric Duct Insert for Size 3 Enclosure. 240V 3 phase, 52 KW maximum - 3 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 29.50" wide and 29.63" tall.

 
EMC3-64KW2403
Electric Duct Insert for Size 3 Enclosure. 240V 3 phase, 64 KW maximum - 3 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 29.50" wide and 29.63" tall.

 
EMC4-168KW4803
Electric Duct Insert for Size 4 Enclosure. 480V 3 phase, 168 KW maximum - 4 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 33.50" wide and 35.63" tall.

 
EMC4-168KW6003
Electric Duct Insert for Size 4 Enclosure. 600V 3 phase, 168 KW maximum - 4 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 33.50" wide and 35.63" tall.

 
EMC4-97KW2403
Electric Duct Insert for Size 4 Enclosure. 240V 3 phase, 97 KW maximum - 4 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 33.50" wide and 35.63" tall.

 
EMC5-151KW2403
Electric Duct Insert for Size 5 Enclosure. 240V 3 phase, 151 KW maximum - 7 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 42.50" wide and 42.63" tall.

 
EMC5-257KW4803
Electric Duct Insert for Size 5 Enclosure. 480V 3 phase, 257 KW maximum - 6 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 42.50" wide and 42.63" tall.

 
EMC5-257KW6003
Electric Duct Insert for Size 5 Enclosure. 600V 3 phase, 257 KW maximum - 5 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 42.50" wide and 42.63" tall.

 
EMC5-334KW4803
Electric Duct Insert for Size 5 Enclosure. 480V 3 phase, 334 KW maximum - 6 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 42.50" wide and 42.63" tall.

 
EMC5-415KW6003
Electric Duct Insert for Size 5 Enclosure. 600V 3 phase, 415 KW maximum - 7 stages total, 1 modulating, de-energizing contactors, 120V fan interlock relay, air pressure switch, control transformer, disconnect switch, and hinged door. Uses A/CP-DO-120-QC Sensor and VT7225 Thermostat. Sensor and Thermostat not included. Coil is 42.50" wide and 42.63" tall.

 
 
 
 

 
 
 